http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
불응축 기체가 존재하는 수직·수평 관내·외부에서의 응축에 대한 문헌연구
김상은(Sangeun Kim),김형대(Hyungdae Kim) 대한기계학회 2013 대한기계학회 춘추학술대회 Vol.2013 No.12
Importance of passive cooling systems operating without electricity during a station blackout accident of nuclear power plants is certainly recognized in the nuclear disaster at Fukushima. Condensation is a key phenomenon in designing and operating passive cooling systems. The presence of non-condensable gases can severely degrade effectiveness of film condensation heat transfer in heat exchanger tubes of passive cooling systems. In this study, an extensive review of previous experimental and theoretical studies on effects of non-condensable gases upon film condensation heat transfer in vertical and horizontal heat exchanger tubes of passive cooling systems was conducted. Key research findings and research gaps identified from this systematic review are presented. Areas for future studies are also suggested along with application to advanced passive cooling systems.
인공 유전체 슬랩을 활용한 소형 광대역 컨포멀 배열 안테나 설계
김상은(Sangeun Kim),유태호(Taeho Yu),문효상(Hyosang Moon),조상왕(Sangwang Cho),변강일(Gangil Byun) 한국전자파학회 2024 한국전자파학회논문지 Vol.35 No.9
In this study, we propose a compact broadband conformal array antenna using artificial dielectric slabs. The proposed antenna consists of three artificial dielectric slabs with a linear impedance distribution stacked on a bow-tie slot antenna. This enables an efficient impedance transition across a wide band from the slot to free space. Each slab is implemented using a sub-wavelength square patch array, achieving a 3:1 bandwidth from 6∼18 GHz. The height of the proposed antenna is 8.24 mm (0.165λ6GHz), with an array distance of 8.33 mm (0.5λ18GHz). The conformal array was designed with a curvature of 27.79° in the H plane. Simulation results show that the proposed antenna maintains an active S-parameter below —10 dB across the target bandwidth and achieves a boresight gain of —4.88 dBi at 6 GHz and 4.8 dBi at 18 GHz. To validate its performance, eight 8×1 arrays were fabricated, combined in the E-plane with a corporate feeding network, and mounted on a curved metallic surface. The measurement results of the fabricated array confirmed that the active S-parameter remained below 10 dB across the target bandwidth. Additionally, post-processing of the measured active element patterns generated beam-steering patterns with a maximum error of 3°.
김상은(SangEun Kim),이준경(Joon-Kyung Lee),이동길(DongGill Lee) 한국정보과학회 2000 정보과학회 컴퓨팅의 실제 논문지 Vol.6 No.3
CHILL language has been used for the software development of electronic switching and telecommunications system. ETRI CHILL-96 language is an extended CHILL language with the notions of object-orientation, concurrency, and generic type. In this paper, we discuss some design and implementation issues of ETRI CHILL-96 compiler. Renaming translation rules and function restructuring techniques are adapted for the purpose of preventing name conflict and producing debugging information. Those new extended features are preprocessed in the compilation and translated to extended CHILL intermediate codes. Such compilation technique enables ETRI CHILL-96 language to hold compatibility with software developed by CHILL language. CHILL 언어는 전전자 교환기 및 통신 시스템용 소프트웨어 개발에 사용되어왔다. ETRI CHILL-96 언어는 객체지향성, 병행성, 포괄적 타입과 같은 특성을 가지고 CHILL 언어를 확장한 것이다. 본 논문에서는 ETRI CHILL-96 컴파일러의 설계 및 구현과 관련된 몇 가지 기술적 주제들에 대해 다룬다. 재명명 변환 규칙들과 함수 재구성 기술들은 이름 충돌의 방지와 풍부한 디버깅 정보의 생성을 위해 사용되었다. 이러한 새로운 확장된 기능들은 확장된 CHILL 중간 코드로 컴파일 및 변환되는 단계에 전처리 되어진다. 이러한 컴파일 기술들은 ETRI CHILL-96언어가 기존의 CHILL 언어에 의해 개발된 소프트웨어들과 호환성을 유지할 수 있게 해 준다.
적외선 입자추적유속계를 이용한 액체-기체 분리유동 시 계면속도 측정기법 개발 및 검증
김상은(Sangeun Kim),김형대(Hyungdae Kim) 대한기계학회 2015 大韓機械學會論文集B Vol.39 No.7
적외선 카메라를 이용한 입자추적유속계(IR-PTV)를 활용하여 물-공기 분리유동 시 계면속도를 측정하는 기법을 개발하였다. 3-5 ㎛ 파장대의 적외선은 물에 대해 20 ㎛ 이하의 침투 깊이를 가지므로 입자추적유속계 기법에 활용 시 물-공기 계면 근처에 존재하는 추적입자들의 이동속도를 선택적으로 측정할 수 있다. IR-PTV 기법의 측정 정확도를 검증하기 위하여 물에 잘 뜨는 스티로폼 입자를 이용하여 10° 기울어진 경사면에서 공기-물 분리유동 시 계면속도를 측정하여 비교한 결과 5% 이내의 오차를 보이면서 잘 일치하였다. 개발한 기법을 이용하여 획득한 실험결과로부터 공기 속도가 증가함에 따라 계면속도가 비례하여 증가하는 것을 관찰하였으며 이는 계면전단력의 증가에 의한 것으로 해석된다. A measurement technique of interfacial velocity in air-water separated flow by particle tracking velocimetry using an infrared camera (IR-PTV) was developed. As infrared light with wavelength in the range of 3-5 um could hardly penetrate water, IR-PTV can selectively visualize only the tracer particles existing in depths less than 20 um underneath the air-water interface. To validate the measurement accuracy of the IR-PTV technique, a measurement of the interfacial velocity of the air-water separated flow using Styrofoam particles floating in water was conducted. The interfacial velocity values obtained with the two different measurement techniques showed good agreement with errors less than 5%. It was found from the experimental results obtained using the developed technique that with increasing air velocity, the interfacial velocity proportionally increases, likely because of the increased interfacial stress.