RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 음성지원유무
        • 원문제공처
          펼치기
        • 등재정보
          펼치기
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        초등교사의 환경관련 수업에 대한 교사전문성

        손연아,김경란,민병미,최돈형 한국초등과학교육학회 2005 초등과학교육 Vol.24 No.2

        The purpose of this study was to analyze the professionalism of elementary school teachers and to draw out factors which elementary teachers should try to improve their professionalism for environmental education. For the study, both Quantitative analysis and qualitative methodologies were applied: First, randomly selected 483 elementary teachers from Seoul and Gyeonggi self responded to 5 evaluation areas by Hungerford et al. (1994) to evaluate their environmental education professionalism through the use of five point Likert scale. Second, 2 elementary teachers' environmental classes were observed for the purpose of analyzing strengths and weaknesses in classroom instruction, and then the results of self-evaluation on environmental education professionalism and teacher professionalism as shown in the classes were compared. It was found that 483 elementary teachers including 2 teachers for analyzing classroom instruction who performed a self-evaluation gave themselves mid-scores on the Hungerford et al.'s 5 evaluation areas. However, the result of self-evaluation did not correspond with the result of actual class observation and teacher interview. That is, the actual environmental classes conducted by 2 teachers did not seemed to reflect the evaluation areas which were the foundation of the study: the conceptual awareness, the investigation & evaluation, environmental action skills, and educational application. The results of this study can be used as the basis reference to develop teaching-learning program and in-service programs for professional development of teachers for successful application of environmental education in elementary school classes.

      • KCI등재

        미니 임플란트 직경에 따른 피로파절강도의 비교 연구

        허유리,손미경,김희중,최한철,정재헌 大韓齒科補綴學會 2012 대한치과보철학회지 Vol.50 No.3

        Purpose: This study was conducted to obtain difference in fracture strength according to the diameter of one-body O-ring-type of mini implant fixture, to determine the resistance of mini implant to masticatory pressure, and to examine whether overdenture using O-ring type mini implant is clinically usable to maxillary and mandibular edentulous patients. Materials and methods: For this study, 13 mm long one body O-ring-type mini implants of different diameters (2.0 mm, 2.5 mm and 3.0 mm) (Dentis, Daegu, Korea) were prepared, 5 for each diameter. The sample was placed at 30 from the horizontal surface on the universal testing machine, and off-axis loading was applied until permanent deformation occurred and the load was taken as maximum compressive strength. The mean value of the 5 samples was calculated, and the compressive strength of implant fixture was compared according to diameter. In addition, we prepared 3 samples for each diameter, and applied loading equal to 80%, 60% and 40% of the compressive strength until fracture occurred. Then, we measured the cycle number on fracture and analyzed fatigue fracture for each diameter. Additionally, we measured the cycle number on fracture that occurred when a load of 43 N, which is the average masticatory force of complete denture, was applied. The difference on compressive strength between each group was tested statistically using one-way ANOVA test. Results: Compressive strength according to the diameter of mini implant was 101.5 ± 14.6 N, 149 ± 6.1 N and 276.0 ± 13.4 N, respectively, for diameters 2.0 mm, 2.5 mm and 3.0 mm. In the results of fatigue fracture test at 43 N, fracture did not occur until 2×106 cycles at diameter 2.0 mm, and until 5×106 cycles at 2.5 mm and 3.0 mm. Conclusion: Compressive strength increased significantly with increasing diameter of mini implant. In the results of fatigue fracture test conducted under the average masticatory force of complete denture, fracture did not occur at any of the three diameters. All of the three diameters are usable for supporting overdenture in maxillary and mandibular edentulous patients, but considering that the highest masticatory force of complete denture is 157 N, caution should be used in case diameter 2.0 mm or 2.5 mm is used. 연구 목적: 일체형의 o-ring type 미니 임플란트 고정체의 직경에 따른 파절강도의 차이를 비교하고자 한다. 연구 재료 및 방법: 길이 13 mm의 one body o-ring type의 미니 임플란트(Dentis, Daegu, Korea)를 직경2.0, 2.5, 3.0 mm 각각 5개씩 준비하였다. Instron universal testing machine 에 수직면에서 30도 각도로 샘플을 위치시키고 off-axis loading을 가하여 영구변형이 일어난 하중 값을 파절강도로 하고 5개의 시편의 평균을 구하여 각 직경에 따른 임플란트의 고정체의 파절강도를 비교하였다. 또한, 각 직경마다 3개의 시편을 준비하고 동적하중 피로 시험기를 이용하여, 파절이 발생할 때까지 파절강도의 80%, 60%, 40%의 loading 을 가하여 파절되는 cycle수를 측정하여 각 직경의 피로 파절을 분석하였다. 추가적으로 총의치의 평균 저작력인 43 N의 하중을 가하여 파절되는 cycle 수를 측정하였다. 각 군간의 차이를 검증하기 위해서 일원분산분석(one-way ANOVA test)을 시행하였고, 통계처리는 SPSS ver.12 (SPSS Inc. Chicago, IL, USA) 을 이용하여 실시하였다. 결과: 직경 3.0 mm 의 미니 임플란트는 평균 276.0 ± 13.4 N의 압축력을 받았을 때 영구 변형이 일어났고 직경 2.5 mm 미니 임플란트가 149.0 ± 6.1 N, 2.0 mm 미니 임플란트가 101.5 ± 14.6 N일 때 영구 변형이 일어났다. 각 군간의 파절강도에는 유의한 차이가 있었다(P<.001). 총의치의 평균 저작력 하중에서 실시한 피로 파절 실험 결과, 세직경 모두 5×106 cycle까지 파절이 일어나지 않았다. 결론: 미니 임플란트의 정적 하중 하에서 최대 압축강도는 직경이 증가할수록 유의적으로 증가하였다. 최대 압축강도는 세 직경 모두 총의치의 평균 저작력 보다는 크나 최대 교합력보다는 직경 3.0 mm에서만 크게 나타났다. 총의치의 평균 저작력 하중에서 실시한 피로 파절 실험 결과, 세 직경 모두 파절이 일어나지 않았다.

      • KCI등재

        열공형과 비열공형 피질하 혈관성 치매에서 위험인자의 차이에 관한 비교 연구

        배희준,정지향,유경호,나덕렬,김상윤,최경규,양동원,손의주,이상도,김재우,박경원,김응규,이재홍,박미영,한일우,함동석,최문성,하충건,최성혜,이애영,이병철,한설희 대한치매학회 2003 Dementia and Neurocognitive Disorders Vol.2 No.2

        Backgrounds and Objectives: Vascular dementia is a group of dementing disoders arising from various stroke syndrome. Among these. subcortical ischemic vascular dementia (SIVD) is regarded as a relatively distinct clinical entity. However, MRI patterns of SIVD are not homogenous. In some patients, lacunes are dominant, and in others, subcortical white matter changes are. This study was designed to compare risk factor profiles between SIVD with and without multiple lacunes. Methods: We divided 47 subjects (22 males, mean age. 68 years) recruited from VADAPET (Multicenter Trial For Evaluation Of The Changes In the PET Images Of Subcortical Vascular Dementia Patient) study into two groups one with more than 5 lacunes in deep gray matter (lacune group) and the other with 5 or less(non-lacune group) Clinical characteristics and laboratory findings of two groups were compared. Results: Nineteen of 47 patients (40%) belonged to the lacune group. The lacune and non-lacune groups d d not differ in the following variables: age, hypertension, diabetes mellitus, hyperlipidemia heart disease, history of stroke or TIA, history of trauma or major surgery, family history of hypertension stroke, or dementia, age at diagnosis of dementia, body mass index, white blood cell count, ESR, CRP, fibrinogen, hemoglobin A1C, total cholesterol. LDL cholesterol creatinine, proteinuria, glucosuria, and microhematuria. However, male sex, smoking alcohol. hemoglobin, and HDL cholesterol were possibly associated more with lacune group SIVD than with non-lacune group (p<0 1) Multivariate analyses revealed that smoking, hemoglobin, and HDL cholesterol were independent predictors of SIVD with multiple lacunes Conclusion: Our study suggests that SIVD with multiple lacunes may be significantly different in smoking habits hemoglobin, and HDL cholesterol from SIVD without multiple lacunes.

      • SCIESCOPUSKCI등재

        Gingival recontouring by provisional implant restoration for optimal emergence profile: report of two cases

        Son, Mee-Kyoung,Jang, Hyun-Seon Korean Academy of Periodontology 2011 Journal of Periodontal & Implant Science Vol.41 No.6

        Purpose: The emergence profile concept of an implant restoration is one of the most important factors for the esthetics and health of peri-implant soft tissue. This paper reports on two cases of gingival recontouring by the fabrication of a provisional implant restoration to produce an optimal emergence profile of a definitive implant restoration. Methods: After the second surgery, a preliminary impression was taken to make a soft tissue working cast. A provisional crown was fabricated on the model. The soft tissue around the implant fixture on the model was trimmed with a laboratory scalpel to produce the scalloped gingival form. Light curing composite resin was added to fill the space between the provisional crown base and trimmed gingiva. After 4 to 6 weeks, the final impression was taken to make a definitive implant restoration, where the soft tissue and tooth form were in harmony with the adjacent tooth. Results: At the first insertion of the provisional restoration, gum bleaching revealed gingival pressure. Four to six weeks after placing the provisional restoration, the gum reformed with harmony between the peri-implant gingiva and adjacent dentition. Conclusions: Gingival recontouring with a provisional implant restoration is a non-surgical and non-procedure-sensitive method. The implant restoration with the optimal emergence profile is expected to provide superior esthetic and functional results.

      • SCIESCOPUSKCI등재

        Effect of cement washout on loosening of abutment screws and vice versa in screw- and cement- retained implant-supported dental prosthesis

        Mee-Kyoung Son,Chae-Heon Chung,Seok-Gyu Kim 대한치과보철학회 2015 The Journal of Advanced Prosthodontics Vol.7 No.3

        PURPOSE The purpose of this study was to examine the abutment screw stability of screw- and cement-retained implant-supported dental prosthesis (SCP) after simulated cement washout as well as the stability of SCP cements after complete loosening of abutment screws. MATERIALS AND METHODS Thirty-six titanium CAD/CAM-made implant prostheses were fabricated on two implants placed in the resin models. Each prosthesis is a two-unit SCP: one screw-retained and the other cemented. After evaluating the passive fit of each prosthesis, all implant prostheses were randomly divided into 3 groups: screwed and cemented SCP (Control), screwed and noncemented SCP (Group 1), unscrewed and cemented SCP (Group 2). Each prosthesis in Control and Group 1 was screwed and/or cemented, and the preloading reverse torque value (RTV) was evaluated. SCP in Group 2 was screwed and cemented, and then unscrewed (RTV=0) after the cement was set. After cyclic loading was applied, the postloading RTV was measured. RTV loss and decementation ratios were calculated for statistical analysis. RESULTS There was no significant difference in RTV loss ratio between Control and Group 1 (P=.16). No decemented prosthesis was found among Control and Group 2. CONCLUSION Within the limits of this in vitro study, the stabilities of SCP abutment screws and cement were not significantly changed after simulated cement washout or screw loosening.

      • KCI등재
      • KCI등재
      • KCI등재

        T-Scan(R)3 시스템의 임상적 적용

        손미경 ( Mee Kyoung Son ),김희중 ( Hee Jung Kim ),강동완 ( Dong Wan Kang ),정재헌 ( Chae Heon Chung ) 조선대학교 구강생물학연구소 2011 Oral Biology Research (Oral Biol Res) Vol.35 No.2

        The diagnosis and establishment of ideal occlusion is most important factor for the patient who needs occlusal treatment or prosthetic rehabilitation. But, traditionally, dentists depend on their experiences to evaluate occlusion. With the development of digital dentistry, a computerized system for an objective analysis of dental occlusion has been introduced and is widely used. The T-Scan(R)III system is a reliable and easy-to-use clinical diagnostic device that recorded and analyzed occlusal contact forces to time using paper-thin sensors. This digital device has application in many phase of dentistry in which occlusal diagnosis and treatment are involved, and remains the only practical quantitative method to analyze the occlusion. In this study, we introduce the T-Scan(R)III system, capabilities and various clinical applications.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼