http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Kobayashi, Hironori,Suzuki, Yumiko,Ajimura, Kosei,Konno, Tomonori,Suzuki, Shunji,Saito, Hiroshi The Korean Society of Plant Biotechnology 2011 Plant biotechnology reports Vol.5 No.1
Vitis vinifera cv. Koshu is a traditional grape cultivar that has been grown for centuries in Japan. The Koshu grape has pink-colored skin and Koshu wines have slight astringency. We demonstrated for the first time the characterization of hydroxycinnamic acids, flavan-3-ols, and flavonoids in Koshu grape using high-performance liquid chromatography and liquid chromatography-mass spectrometry. The gross weight of phenolic compounds excluding anthocyanins and proanthocyanidins in Koshu grape at harvest was higher than those in Sauvignon Blanc, Chardonnay, and Merlot grapes. In addition, hydroxycinnamic acid and monomeric flavonol contents in Koshu grape were also higher than those in the other grape cultivars. Transcription analysis of cinnamic acid 4-hydroxylase, p-coumarate 3-hydroxylase, caffeate methyltransferase, and flavonol synthase genes indicated high accumulation of hydroxycinnamic acids and flavonols in Koshu grape skin compared with the other cultivars. These findings obtained by chemical and molecular approaches partially explained the phenolic characteristics and the peculiar astringency of Koshu grape.
ALUMINUM BIAS SPUTTERING FOR FILM COVERAGE IMPROVEMENT
Kobayashi.Shigeru,Shimamura, Hideaki,Sakata, Masao,Fujita, Shouyou,Yajima, Akira,Saito, Hiroshi,Tateishi, Hideki,Sasaki, Shinji 대한전자공학회 1989 ICVC : International Conference on VLSI and CAD Vol.1 No.1
A filter was installed between the sputtering target and the substrate so as to reduce the aluminum deposition arriving with a shallow angle at the substrate in order to study the step coverage improvement by the bias application. It is deduced that the aluminum flowage occurs so that the surface energy is minimized around the via hole. Aluminum films deposited with the pulsed biasing were characterized in which the possible microstructual damage by argon bombardment is to be minimized. This biasing technique should provide with a better process for the step coverage improvement. A sputtering cathode was developed for aluminum bias sputtering which has a substrate current capability as high as 2A for a 5 inch wafer at the substrate voltage around-50V.
Hiroshi Nakagawara,Kenji Yamao,Takuji Gotoda,Daiichiro Kikuta,Akinori Takei,Kunio Iwatsuka,Toshimi Takahashi,Masahiro Ogawa,Akihiro Henmi,Makio Kobayashi,Mitsuhiko Moriyama 소화기인터벤션의학회 2019 Gastrointestinal Intervention Vol.8 No.2
Background: Endoscopic-guided placement of metal stents for unresectable malignant hilar biliary obstruction (UMHBO) is performed using partial stent-in-stent or side-by-side (SBS) techniques. The latter involves placing sequential stents within the bile duct. Excessive dilation of the bile duct during stent placement can have serious effects on the surrounding organs.Methods: This study details seven cases of SBS placement of 8.0 mm metal stents for UMHBO. Histopathological examinations were performed to identify the effects on the bile duct and surrounding tissues.Results: The mean post-placement diameter of the bile ducts was 13.86 mm, and no compression necrosis or thrombi were observed in surrounding tissues. Cholangitis occurred in five cases, and death occurred as a result of cholecystitis in one case. Conclusion: The use of 8.0-mm stents for SBS is unlikely to have major negative effects on peribiliary tissues and blood vessels. However, post-placement cholecystitis can result in increased mortality; thus, gallbladder drainage should be considered.
Hiroshi Yoshida,Hiroko Machida,Koji Matsuo,Yoshito Terai,Takuma Fujii,Masaki Mandai,Kei Kawana,Hiroaki Kobayashi,Mikio Mikami,Satoru Nagase 대한부인종양학회 2023 Journal of Gynecologic Oncology Vol.34 No.3
Objective: Owing to the potential benefits of minimally invasive hysterectomy for endometrial cancer, the practice pattern has recently shifted in Japan. This study examined the trends in minimally invasive surgery (MIS) in patients with endometrial cancer in Japan. Methods: This retrospective observational study examined the Japan Society of Obstetrics and Gynecology Tumor Registry database between 2015–2019. This study examined the time-specific proportion change and predictors of MIS use in initial endometrial cancer treatment in Japan, and compared it with the use of abdominal surgery. Additionally, the association between hospital surgical treatment volume and MIS use was examined. Results: A total of 14,059 patients (26.5%) underwent minimally invasive hysterectomy, and 39,070 patients (73.5%) underwent abdominal hysterectomy in the study period. Patients who underwent MIS were more likely to be treated at high-volume centers, younger, central, or western Japan residents, registered in recent years, and had a tumor with stage I disease, type 1 histology, and less myometrial invasion (all adjusted p<0.05). The proportion of MIS treatments increased from 19.1% in 2015 to 34.3% in 2019 (p<0.001). On multivariable analysis, treatment at high-volume centers was a contributing factor for MIS (adjusted odds ratio=3.85; 95% confidence interval=3.44–4.30). MIS at high-volume centers increased significantly from 24.8% to 41.0% (p<0.001) during the study period, whereas MIS at low-volume centers remained at median 8.8%. Conclusion: MIS has increased significantly in recent years, accounting for nearly 34% of surgical management of endometrial cancer in Japan. High-volume treatment centers take the lead in performing MIS.
Hiroshi Nakagawara,Kenji Yamao,Takuji Gotoda,Daiichiro Kikuta,Akinori Takei,Kunio Iwatsuka,Toshimi Takahashi,Masahiro Ogawa,Akihiro Henmi,Makio Kobayashi,Mitsuhiko Moriyama 소화기인터벤션의학회 2019 International journal of gastrointestinal interven Vol.8 No.2
Background: Endoscopic-guided placement of metal stents for unresectable malignant hilar biliary obstruction (UMHBO) is performed using partial stent-in-stent or side-by-side (SBS) techniques. The latter involves placing sequential stents within the bile duct. Excessive dilation of the bile duct during stent placement can have serious effects on the surrounding organs.Methods: This study details seven cases of SBS placement of 8.0 mm metal stents for UMHBO. Histopathological examinations were performed to identify the effects on the bile duct and surrounding tissues.Results: The mean post-placement diameter of the bile ducts was 13.86 mm, and no compression necrosis or thrombi were observed in surrounding tissues. Cholangitis occurred in five cases, and death occurred as a result of cholecystitis in one case. Conclusion: The use of 8.0-mm stents for SBS is unlikely to have major negative effects on peribiliary tissues and blood vessels. However, post-placement cholecystitis can result in increased mortality; thus, gallbladder drainage should be considered.