http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
가역적 수소 저장을 위한 마그네슘 알라네이트 (Mg(AlH4)2) 나노 입자 활용: 밀도범함수이론 연구
임동희,배은민,한영수 한국수소및신에너지학회 2023 한국수소 및 신에너지학회논문집 Vol.34 No.2
Phase stability diagrams were constructed for magnesium alanate (Mg(AlH4)2) nanoparticles to investigate the reversible hydrogen storage reaction by using density functional theory. Our findings indicate that bulk Mg(AlH4)2 shows favorable hydrogen release, but unfavorable hydrogen uptake (adsorption) reactions. However, for Mg(AlH4)2 nanoparticles, it was observed that hydrogen release and recharge can be achieved by controlling the particle size and temperature. Furthermore, by predicting the decomposition phase diagram of Mg(AlH4)2 nanoparticles with varying hydrogen partial pressure, it was discovered that reversible dehydrogenation reactions can occur even in relatively large nanoparticles by controlling the hydrogen partial pressure.
임동희,최성호,정태영,정의상 대한안과학회 2013 Korean Journal of Ophthalmology Vol.27 No.2
Purpose: To assess the refractive change and prediction error after temporary intraocular lens (IOL) removal in temporary polypseudophakic eyes using IOL power calculation formulas and Gills’ formula. Methods: Four consecutive patients (7 eyes) who underwent temporary IOL explantation were enrolled. Postoperative refractions calculated using IOL power calculation formulas (SRK-II, SRK-T, Hoffer-Q, Holladay, and the modified Gills’ formula for residual myopia and residual hyperopia) were compared to the manifest spherical equivalents checked at 1 month postoperatively. Results: The mean ages of temporary piggyback IOL implantation and IOL removal were 6.71 ± 3.68 months (range, 3 to 12 months) and 51.14 ± 18.38 months (range, 29 to 74 months), respectively. The average refractive error was -13.11 ± 3.10 diopters (D) just before IOL removal, and improved to -1.99 ± 1.04 D after surgery. SRK-T showed the best prediction error of 1.17 ± 1.00 D. The modified Gills’ formula for myopia yielded a relatively good result of 1.47 ± 1.27 D, with only the variable being axial length. Conclusions: Formulas to predict refractive change after temporary IOL removal in pediatric polypseudophakia were not as accurate as those used for single IOL implantation in adult eyes. Nonetheless, this study will be helpful in predicting postoperative refraction after temporary IOL removal.
New! 안전시설 & 보호구: 응급조치에 최적화된 '일진약품 구급함'
임동희,Im, Dong-Hui 대한산업안전협회 2011 안전기술 Vol.160 No.-
일진약품은 응급구급함 및 구급장비 제작에 외길을 걸어온 회사로, 이 분야의 선도적인 위치에 있는 기업이다. 인간존중의 이념 아래 실용적이고 차별성 있는 제품을 만들기 위해 부단히 노력하고 있다는 일진약품을 찾아가 봤다.
New! 안전시설 & 보호구 - 친환경의 다양한 안전제품" 인기
임동희,Im, Dong-Hui 대한산업안전협회 2012 안전기술 Vol.170 No.-
'안전'과 '환경', 최근 사회적으로 중요성이 강조되고 있는 단어다. (주)정오에스티에스(대표 류재동)는 이 두 가지를 기장 큰 가치로 여기고 각종 안전용품을 산업현장에 보급시켜 나가고 있다. 안전하고 친환경적인 제품이어야 근로자들의 안전은 물론 건강도 보호할 수 있다고 믿기 때문이다. 정오에스티에스의 신념이 그대로 묻어난 제품 몇 가지를 소개해보고자 한다.
New! 안전시설 & 보호구 - 건설편장의 추락 및 낙화.비래 "원천적차단" - (주)기성-일체형고소안전작업대
임동희,Im, Dong-Hui 대한산업안전협회 2012 안전기술 Vol.172 No.-
건설현자의 경우 고령근로자가 많고, 현장 구성원의 이동이 잦기 때문에 사고가 많이 발생할 수밖에 없습니다. 하지만 근로자들이 보호구를 착용하고, 현장에서도 안전시설을 확실히 설치해둔다면 그 피해는 크게 줄일 수 있다고 확신합니다. 사고는 한순간의 방심과 과오를 통해 발생합니다. 현장 관계자 모두가 이 사실을 명심하고 항상 기본을 지키는 습관을 가지시기 바랍니다. 또 현장에서는 질 좋은 보호구와 안전시설을 통해 근로자들의 근원적인 안전을 확보해주시기 바랍니다. 우리(주)기성의 30여명 임직원들도 우리나라 산업현장의 특성에 맞는 제품들을 꾸준히 연구 개발해나가면서, 산업 안전을 지키려는 많은 분들의 발걸음에 동참해나가도록 하겠습니다.