http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
김평수(P. S. Kim),이응혁(E. H. Lee),장문석(M. S. Jang) 한국재활복지공학회 2014 한국재활복지공학회 학술대회논문집 Vol.2014 No.11
In order that patients in home networks can get opportunities for useful remote healthcare services beyond Legacy Internet Protocol TV (IPTV) services, this paper proposes a home network based 3rd-party remote healthcare IPTV service platform. The proposed service platform is operated as an "add-on" solution on the existing home gateway that can interwork home network and IPTV, and can be a gateway for home network as well as wireless sensor network(WSN)/wireless body area network(WBAN). The proposed service platform provides open architecture and functionalities to enable 3rd-party remote healthcare IPTV service providers to deliver locally and directly their healthcare services to patients in home networks. The open architecture and functionalities of the proposed home network based 3rd-party remote healthcare IPTV service platform are defined and their requirements are specified. In addition, the operation procedure for home network based remote healthcare IPTV service using the proposed service platform is presented.
u-헬스케어 시스템에서 멀티 생체신호 측정 무선 단말기 설계 및 구현
장문석(M. S. Jang),엄수홍(S. H. Eom),김평수(P. S. Kim),이응혁(E. H. Lee) 한국재활복지공학회 2013 재활복지공학회논문지 Vol.7 No.2
기존의 u-헬스케어 시스템의 생체 신호 측정 단말기는 단말기에서 하나의 생체 신호를 측정하여 평가하는 것이 대부분이고, 복합된 기능의 단말기이더라도 사용자의 선택에 의해서 생체 신호를 측정하도록 되어있다. 본 논문에서는 이러한 문제점을 해결하고, u-헬스케어 시스템에 적용하기 위한 멀티 생체신호 측정무선 단말기를 구현하였다. 구현된 단말기는 4개의 적외선 센서를 사용하여 맥박수를 측정하고, 2개의 전극을 이용하여 피부전도도를 측정하고, 3축 가속도 센서를 사용하여 운동량을 측정하였다. 뿐만 아니라, 생체신호 데이터를 무선으로 전송하기 위해 지그비를 이용하여 PC 또는 휴대단말기로 전송할 수 있는 통신 패킷 프레임을 제안한다. 무선 단말기를 구현하여 실제 테스트한 결과 맥박 수는 2회 이내의 오차 범위를 가지고, 운동량은 약 85.6%, 84.7%의 신뢰도를 보였으며, 피부전도도는 사용자의 신체 상태에 따라 변화함을 알 수 있었다. Most of existing biomedical signal measurement devices measure and evaluate biomedical signal only in a single device. Also, even if the device is multi-functional, those biomedical signals can be measured by selection of the user. In this paper, we implemented wristband-style biomedical signal measurement device for u-healthcare system to solve the problem above. Implemented device uses 4 infrared sensors to measure the pulse, 2 electrodes to measure the skin conductivity, and 3-axis accelerometer to measure momentum. Also, we propose a communication packet frame for transmitting biomedical signal data to PC or mobile device, using Zigbee. Studies show that our device has the error rate of less than twice for pulse measurement, 85.6%, 84.7% reliability for momentum measurement, and the skin conductivity has changed according to the user"s physical status.
알루미늄 합금의 아크 용접부에 대한 레이저 쇼크 피닝 적용 시 레이저빔 중첩률의 영향에 대한 기초 연구
윤예솔(Y. S. Yun),김지언(J. E. Kim),김평수(P. S. Kim),김종도(J. D. Kim) Korean Society for Precision Engineering 2021 한국정밀공학회 학술발표대회 논문집 Vol.2021 No.11월
알루미늄 합금의 MIG 용접부는 아크열원에 의해 용접이 이루어지기 때문에 입열량이 크고, 모재 및 용가재가 용융 및 응고되는 과정에서 용융 금속의 팽창과 수축이 발생하여 용접부 내부 및 주변에 전반적으로 인장잔류응력이 형성된다. 이와 같이 용접부에 형성되는 인장잔류응력을 개선하기 위하여 레이저 쇼크 피닝(LSP)을 통한 용접 후처리 공정이 필요하다. 레이저 쇼크 피닝은 높은 피크 출력의 단펄스 레이저로 재료 표면에 충격을 가하여 소성변형을 부여함으로서 표면을 강화하는 용접 후 처리 기술이다. 따라서, 본 연구에서는 알루미늄 합금 아크 용접부의 성능향상을 위한 레이저 쇼크 피닝 기초 연구를 진행하였다. 두께 10 mm 의 알루미늄 3000 계 합금이 모재로 사용되었으며, MIG 용접시 와이어 재료로는 알루미늄 4000 계 합금이 사용되었다. 실험에 사용된 레이저는 Q-switched Nd:YAG 레이저이다. 레이저 피닝 실험은 레이저빔 중첩률과 같은 공정 변수를 변화시키면서 진행되었다. 레이저 피닝 전·후 시험편의 기계적 특성 분석을 위하여 XRD 표면 잔류응력 측정기와 마이크로 비커스 경도 시험기를 사용하였다. 실험 결과, 용접부 표면의 인장잔류응력은 레이저 쇼크 피닝 후에 압축응력 상태로 변화되었다. 또한 레이저 쇼크 피닝 후 용접부 표면의 경도를 크게 개선시킬 수 있었다.
엄수홍(S. H. Eom),고민수(M. S. Goh),김평수(P. S. Kim),이응혁(E. H. Lee) 한국재활복지공학회 2011 한국재활복지공학회 학술대회논문집 Vol.2011 No.11
Recently, potable biosignal measurement systems are focusing on wearability and mobility. Accordingly, it acquires a greater importance to make a small, low-electric product of biosignal measurement systems. This paper describes trends of developing technology of portable biosignal measurement system through cases by each wearing type.