http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
BD-R 장기보존 특성 평가를 위한 가속 열화 실험 조건과 안정성 평가 기준에 관한 연구
이관용,박선주,김도현,조이형,김영주,Lee, Kwan-Yong,Park, Sun-Joo,Kim, Do-Hyun,Jo, Yi-Hyung,Kim, Young-Joo 정보저장시스템학회 2014 정보저장시스템학회논문집 Vol.10 No.1
The Blu-ray Disc Recordable(BD-R) is one of strong candidates for archival application among optical media formats, because of its large capability. However, the well-defined accelerated aging test conditions and evaluation criteria have not yet been fully confirmed for BD-R. In this study, the data stability and degradation aspect of BD-R were analyzed by the random-symbol error rate(R-SER) measurement after the accelerated aging test. And a reasonable test condition of accelerated aging for BD-R and the appropriate evaluation criterion using R-SER measurement were discussed.
도시지역 CSOs 저감을 위한 저류조 및 이송관로의 최적 용량결정에 관한 연구
이관용,최원석,이용재,구원석,송창수 대한상하수도학회 2012 상하수도학회지 Vol.26 No.6
Storage method is one of major measures for reduction of CSOs pollutant loads and several projects have been done nationwide. But systematic analysis of intercepting capacity has not been studied to determine optimum size of storage facility. In this research, not only storage volume but also intercepting capacity which means flow capacity from intercepting facility to CSOs storage facility was studied and optimum sizing method for storage facility was proposed. The result shows that pollutants reduction efficiency can be increased significantly by increasing intercepting capacity and it might reduce storage volume and total construction costs. Intercepting capacity for the study area was evaluated and it was shown as equivalent to 83 % probability rainfall intensity. Storage method is one of major measures for reduction of CSOs pollutant loads and several projects have been done nationwide. But systematic analysis of intercepting capacity has not been studied to determine optimum size of storage facility. In this research, not only storage volume but also intercepting capacity which means flow capacity from intercepting facility to CSOs storage facility was studied and optimum sizing method for storage facility was proposed. The result shows that pollutants reduction efficiency can be increased significantly by increasing intercepting capacity and it might reduce storage volume and total construction costs. Intercepting capacity for the study area was evaluated and it was shown as equivalent to 83 % probability rainfall intensity.
폐활성슬러지와 분뇨의 S/I 비에 따른 혐기성 소화 특성에 관한 연구
이관용,이성준,오두영,김대기,박기영 한국폐기물자원순환학회(구 한국폐기물학회) 2014 한국폐기물자원순환학회 심포지움 Vol.2014 No.2
하수슬러지를 비롯한 유기성 폐기물의 해양투기는 2013년 이후부터 전면 금지되었으며, 이를 육상처리하기 위한 방법들이 다각도로 연구되고 있다. 특히 유기성 폐기물의 혐기성 소화방법은 하수슬러지 등의 감량화 뿐만 아니라 부산물로 발생되는 바이오가스(CH<sub>4</sub>, CO<sub>2</sub>)를 이용한 에너지화 공정으로 알려져 있다. 오랜 세월 동안 혐기성 소화를 이용한 다양한 유기성 폐기물의 처리가 진행되어 오면서 공법과 운전 기술의 발달로 세계 각국에서 활용하고 있지만 유기성 폐기물의 다양성과 특성의 변화에 따라 혐기성소화조 환경에 일률적인 적용이 쉽지 않다. 따라서 다양한 유기성 폐기물에 맞는 혐기성소화 조건의 확립이 중요하다 할 수 있다. 본 연구에서는 유기성 폐기물 중 폐활성슬러지와 분뇨의 기질과 혐기성소화 미생물의 비(ratio)에 따른 혐기성 소화특성에 대한 연구를 하고자 하였으며, 각 유기성 폐기물에 따른 적절한 미생물 비를 알아보고자 하였다. 이를 위해 각 기질과 혐기성소화 미생물의 비를 0.3, 0.5, 1, 2, 5로 조절하여 메탄 잠재량 분석방법(BMP; Biochemical Methane Potential)을 통하여 바이오가스 생산량 비교와 메탄 생산량 등을 분석하였다. 또한 전처리에 의한 고형물 감량 효과를 측정하기 위하여 휘발성 고형물 감량율(VSR; Volatile solid reduction)을 분석하였다. 분뇨의 경우 기질과 혐기성 미생물 비가 가장 낮은 0.3일 때 바이오가스 누적량이 가장 높은 약 320 mL/g-VS으로 나타났으며, 폐활성슬러지의 경우 역시 기질과 혐기성소화 미생물비가 가장 낮은 0.3일 때 약 550 mL/g-VS의 바이오가스 발생량을 보였다. 혐기성소화 바이오가스 발생에 있어 기질과 미생물의 비에 따라 최종 바이오가스 발생량이 달라질 수 있으며, 이에 따라 적절한 기질과 미생물 비를 고려한 운전이 주요할 것으로 판단된다.