http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
김태훈,유영훈,김형중,안철민,백효채,이두연,김상진,Kim, Tae-Hun,Yu, Yeong-Hun,Kim, Hyeong-Jung,An, Cheol-Min,Baek, Hyo-Chae,Lee, Du-Yeon,Kim, Sang-Jin 대한영상의학회 2003 대한영상의학회지 Vol.49 No.4
Purpose: To elucidate the sequential radiologic manifestations of reperfusion edema after lung transplantation. Materials and Methods: The study group comprised five consecutive lung transplant recipients (M:F=3:2; mean age; 47.5 years) who between July 1996 and April 2002 underwent lung transplantation procedures (four, unilateral; one, bilateral) at our institution. We retrospectively reviewed the serial postoperative radiographs obtained and characterized the lung infiltrates. Results: Lung infiltrates compatible with reperfusion edema were present in all patients (5/5). Reperfusion edema appeared on day 1 in four, and by day 2 in the other. In all transplanted lungs, infiltrates were found in the perihilar and basilar regions, and were scored as maximal on day 1 in one, day 3 in two, day 4 in one and day 5 in the other. Conclusion: The recognition of sequential radiological manifestations helps identify recognition of reperfusion edema after lung transplantation. 목적: 본 연구는 폐이식후 재관류부종의 시기에 따른 방사선적 소견을 기술하려고 한다. 대상과 방법: 본원에서 폐이식을 시행받은 5명의 수여자를 대상으로 하였다. 1996년 7월부터 2002년 3월까지 세 명의 남자와 두 명의 여자가 폐이식을 받았고, 평균 연령은 47.5세 였다. 이 중 4 명은 한쪽 폐만 이식을 받았고, 1명은 양폐 이식을 받았다. 모든 수술후 연속적인 수술후 방사선 사진을 분석하고, 폐음영을 기술 하였다. 결과: 재관류부종은 네 명에서는 수술후 1일째에 , 한 명에서는 2일째에 나타났다. 최대치의 폐음영은 한 명에서 수술후 1일에, 두 명에서 수술후 3일째에, 한 명에서 4일째에, 나머지 한 명은 술후 5일째에 있었다. 결론: 재관류부종은 모든 폐이식 이후에 일어나는 현상이며 방사선학적으로는 폐문주위와 하폐에 우세하게 분포하는 미세 망상형 또는 기강경화로 나타나며, 약 5일 이내에 최대 시기를 거치고 3주 이내에 특별한 치료없이 소실된다.
224비트 ECDSA 하드웨어 시간 시뮬레이션을 위한 테스트벡터 생성기
김태훈,정석원,Kim, Tae Hun,Jung, Seok Won 한국사물인터넷학회 2015 한국사물인터넷학회 논문지 Vol.1 No.1
하드웨어는 다양한 구조로 개발되고, 모듈들에 대한 시간 시뮬레이션을 할 때 각 클럭 사이클에 사용되는 변수들의 값을 확인할 필요가 있다. 본 논문은 224비트 ECDSA 하드웨어를 개발하면서 하드웨어 모듈의 시간 시뮬레이션을 위한 테스트 벡터를 제공하는 소프트웨어 생성기를 소개한다. 테스트 벡터는 GUI 형태와 텍스트 파일 형태로 제공된다. Hardware are developed in various architecture. It is necessary to verifying value of variables in modules generated in each clock cycles for timing simulation. In this paper, a test vector generator in software type generates test vectors for timing simulation of 224-bit ECDSA hardware modules in developing stage. It provides test vectors with GUI format and text file format.
스타이렌 공중합체의 물리적 특성 및 콘택트 렌즈로의 응용
김태훈,예기훈,성아영,Kim, Tae-Hun,Ye, Ki-Hun,Sung, A-Young 대한화학회 2009 대한화학회지 Vol.53 No.6
Styrene은 중합체와 공중합체로 널리 사용되어져 왔으며, 고 굴절률을 가지고 있기 때문에 콘택트렌즈 재료로 유용하게 사용된다. 본 연구는 styrene을 교차결합제인 EGDMA (ethylene glycol dimethacrylate)와 HEMA (2-hydroxyethyl methacrylate) 그리고 개시제인 AIBN (azobisisobutyronitrile)을 사용하여 공중합 하였다. 공중합한 안 의료용 재료의 물리적 특성을 측정한 결과 굴절률 1.4412-1.4628, 함수율 20-35%, 가시광선 투과율 82.6-87.0%, 인장강도 0.143-0.344 Kgf를 나타내었다. Styrene의 비율이 증가할수록 굴절률과 인장강도는 증가하였으며, 함수율은 감소하였다. 본 실험결과로 볼 때 생성된 공중합체는 기능성을 가진 고성능 콘택트렌즈 재료로 사용될 수 있을 것으로 판단된다. Styrene is broadly used as a polymer and a copolymer and is useful in manufacturing contact lenses due to its high refractive index. This study used styrene with the cross-linker EGDMA (ethylene glycol dimethacrylate), HEMA (2-hydroxyethyl methacrylate) and the initiator AIBN (azobisisobutyronitrile) for copolymerization. Measurement of the physical characteristics of the copolymerized material showed that the refractive index is 1.4412 - 1.4628, water content 20 - 35%, visible transmittance 82.6 - 87% and the tensile strength 0.143 - 0.344 Kgf. Also, measurements showed that the refractive index and tensile strength increased while the water content decreased as the ratio of styrene increased. Based on the results of this study, the produced copolymer can be estimated to be suitable for use as a material for high performance functional contact lenses.
4-Fluorostyrene을 포함하는 안의료용 고분자 합성 및 물리적 특성
김태훈,성아영,Kim, Tae-Hun,Sung, A-Young 대한화학회 2010 대한화학회지 Vol.54 No.3
본 연구는 4-fluorostyrene을 교차결합제인 EGDMA (ethylene glycol dimethacrylate)와 HEMA (2-hydroxyethyl methacrylate) 그리고 개시제인 AIBN (azobisisobutyronitrile)과 함께 공중합 하였다. 생성된 고분자의 물리적 특성을 측정한 결과, 함수율 19.98 ~ 31.08%, 굴절률 1.443 ~ 1.475, 가시광선 투과율 87 ~ 93%, 인장강도 0.246 ~ 0.311 kgf 그리고 접촉각의 경우 54.14 ~ $66.95^{\circ}$ 범위의 분포를 나타내었다. 4-Fluorostyrene 첨가한 콘택트렌즈 재료의 경우, 기본적인 콘택트렌즈의 물성을 만족하였고, styrene 비교하여 함수율의 큰 변화를 나타내지 않으면서도 습윤성과 굴절률을 증가시키는 결과를 나타내었다. 본 실험결과로 볼 때 생성된 공중합체는 고 굴절률과 습윤성을 지닌 콘택트렌즈 재료로 사용될 수 있을 것으로 판단된다. This study used 4-fluorostyrene with the cross-linker EGDMA (ethylene glycol dimethacrylate), HEMA (2-hydroxyethyl methacrylate) and the initiator AIBN (azobisisobutyronitrile) for copolymerization. Measurement of the physical properties of the copolymerized polymer showed that the water content was 19.98 ~ 31.08%, refractive index 1.443 ~ 1.475, visible transmittance 87 ~ 93% and tensile strength 0.246 ~ 0.311 kgf while the contact angle showed a distribution between $54.14^{\circ}$ and $66.95^{\circ}$. Therefore, the ophthalmic material produced using 4-fluorostyrene satisfied the basic physical properties required for contact lenses and also showed an increase in wettability and refractive index while having no significant change in water content with relation to styrene. Based on the results of this study, the produced copolymer is suitable for use as a material to high refractive index and wettability contact lenses.
프로필렌 글리콜을 첨가제로 사용한 고분자재료의 물성 및 콘택트렌즈 응용
김태훈,성아영,Kim, Tae-Hun,Sung, A-Young 대한화학회 2010 대한화학회지 Vol.54 No.1
Propylene glycol을 첨가제로 사용하여 HEMA (2-hydroxyethyl methacrylate)와 교차결합제인 EGDMA (ethylene glycol dimethacrylate) 그리고 개시제인 AIBN(azobisisobutyronitrile)을 사용하여 공중합 하였다. 생성된 고분자의 물리적 특성을 측정한 결과, 함수율 37.06~38.71%, 굴절률 1.492~1.432, 가시광선 투과율 89.4~91.5%, 인장강도 0.1416~0.2302 kgf 그리고 접촉각의 경우 $38.60{\sim}53.53^{\circ}$ 범위의 분포를 나타내었다. 따라서 propylene glycol을 첨가한 콘택트렌즈 재료의 경우, 기본적인 콘택트렌즈의 물성을 만족하였으며 함수율의 큰 변화를 나타내지 않으면서도 습윤성과 인장강도를 증가시키는 결과를 보여주었다. HEMA (2-hydroxyethyl methacrylate), EGDMA (ethylene glycol dimethacrylate) and propylene glycol was copolymerized in the presence of AIBN (azobisisobutyronitrile) initiator in a mould. The physical properties of the contact lens were measured. The water content of 37.06~38.71%, refractive index of 1.492~1.432, visible transmittance of 89.4~91.5%, tensile strength of 0.1416~0.2302 kgf, and contact angle of $38.60{\sim}53.53^{\circ}$ were obtained. Therefore, the contact lens material produced using propylene glycol as an additive satisfied the basic physical properties required for contact lenses application. It is interesting to note that an increase in wettability and tensile strength while having no significant changes in water content.