http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
공병진,박다인,변상호,이상호 한국기계기술학회 2023 한국기계기술학회지 Vol.25 No.6
Air blower has been widely used in many industrial fields such as wind tunnel and large ventilation systems. Its performance is affected by operating conditions and system geometry of inpeller and duct, and these design parameter optimization is essential for the effective development. CFD analysis is carried out to investigate the air flow field characteristics with outlet total pressure in a blower system. Intake air into the impeller blade through the inlet is compressed, and then gradually discharged from the outlet with ascending total pressure, and predicted results are compared with test data. Especially this overall pressure difference in the blower system severely depends on the flow rate. These results are expected to be used as applicable design data for blower performance improvement.
변상호,박다인,공병진,이상호 한국기계기술학회 2023 한국기계기술학회지 Vol.25 No.6
Application areas of floating marine structure systems have been increased with the development of power generation systems using renewable energy. Hence it is necessary to analyze the behavior of these floating systems for efficient design and operation. In this study, a computational analysis was performed to predict the characteristics of mooring lines load variation connected to a floating marine structure with waves. Pressure on the floating body and mooring lines load were analyzed with wave direction and height. The floating body stability severely decreased for 90° of the wave incident direction, and maximum load of the mooring lines increased with the height. These results are expected to be applicable for optimal design of the marine floating system.
Seismic Fragility Analysis of Buildings With Combined Shear Wall-Damper System
라지불이슬람,수딥타차크라보르티,공병진,김두기 한국지진공학회 2023 한국지진공학회논문집 Vol.27 No.2
Structural vibration induced by earthquake hazards is one of the most significant concerns in structure performance-based design. Structural hazards evoked from seismic events must be properly identified to make buildings resilient enough to withstand extreme earthquake loadings. To investigate the effects of combined earthquake-resistant systems, shear walls and five types of dampers are incorporated in nineteen structural models by altering their arrangements. All the building models were developed as per ACI 318-14 and ASCE 7-16. Seismic fragility curves were developed from the incremental dynamic analyses (IDA) performed by using seven sets of ground motions, and eventually, by following FEMA P695 provisions, the collapse margin ratio (CMR) was computed from the collapse curves. It is evident from the results that the seismic performance of the proposed combined shear wall-damper system is significantly better than the models equipped with shear walls only. The scrutinized dual seismic resisting system is expected to be applied practically to ensure a multi-level shield for tall structures in high seismic risk zones.