<P>This paper presents a square patch capacitive voltage divider (CVD) for measuring high-voltage ultrawideband pulses in a coaxial pulse forming line. The dimension parameters and the sensitivity factor of the CVD are expressed as functions of ...
http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
https://www.riss.kr/link?id=A107707153
2016
-
SCOPUS,SCIE
학술저널
680-684(5쪽)
0
상세조회0
다운로드다국어 초록 (Multilingual Abstract)
<P>This paper presents a square patch capacitive voltage divider (CVD) for measuring high-voltage ultrawideband pulses in a coaxial pulse forming line. The dimension parameters and the sensitivity factor of the CVD are expressed as functions of ...
<P>This paper presents a square patch capacitive voltage divider (CVD) for measuring high-voltage ultrawideband pulses in a coaxial pulse forming line. The dimension parameters and the sensitivity factor of the CVD are expressed as functions of the low-frequency cutoff and the high-frequency cutoff of the pulse waveform via a theoretical analysis in frequency domain. A coaxial line integrated with a square patch CVD is designed, manufactured, and tested. A 1.3-ns bipolar pulse is measured by the CVD. The experimental results demonstrated that the waveform measured by the CVD was nearly identical to the reference waveform and the error of the maximum amplitude was 2.1%.</P>