RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재

      KVN과 동아시아 VLBI 관측시설을 이용한 SiO 메이저 모델이미지 모의실험 = IMAGE SIMULATIONS OF THE KVN AND EAST ASIA VLBI FACILITIES WITH A SiO MASER MODEL IMAGE

      한글로보기

      https://www.riss.kr/link?id=A101343193

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      We report results of image simulations of the KVN and VLBI experiments of the KVN with several other East Asia VLBI facilities. To investigate their imaging capability a model-generated image of 7 mm SiO maser emission in Mira variables is used. The r...

      We report results of image simulations of the KVN and VLBI experiments of the KVN with several other East Asia VLBI facilities. To investigate their imaging capability a model-generated image of 7 mm SiO maser emission in Mira variables is used. The resulting simulations show that the joint VLBI experiments of the KVN with East Asia VLBI facilities can produce reasonably good images at 7 mm spectral line experiments. However, there are no apparent differences in peak flux densities and images themselves in the simulations among different combinations of these facilities. In addition, the simulated images of observations which include bigger antennas do not show any expected improvement to the image sensitivity. The small variations in the peak flux density and similar image sensitivity, irrespective of different antenna sizes or numbers of baselines used in the simulations, turn out due to a specific characteristic of the adopted model image. Test simulations using another SiO maser image from R Cas observations prove that the participation of bigger antennas in the VLBI experiments does improve image sensitivity. We confirm the need of additional longer baselines in the experiments of the East Asia VLBI facilities to study very compact maser clumps on sub-milliarcsecond scales.

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼