RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재 SCOPUS

      Development of a method for the determination of 4-(methylnitrosamino)- 1-(3-pyridyl)-1-butanone in dust using liquld chromatography tandem mass spectrometry

      한글로보기

      https://www.riss.kr/link?id=A104831506

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK), a tobacco specific nitrosamine found only intobacco products. The ability to monitor biomarker concentrations is very important in understanding environmentaltobacco smoke (ETS). In this study, an ...

      4-(methylnitrosamino)-1-(3-pyridyl)-1-butanone (NNK), a tobacco specific nitrosamine found only intobacco products. The ability to monitor biomarker concentrations is very important in understanding environmentaltobacco smoke (ETS). In this study, an efficient and sensitive method for the analysis of NNK in dust wasdeveloped and validated using liquid chromatography tandem mass spectrometry. Dust was collected with filterpaper soaked in methanol. The standard solution and dust sample were diluted with 100 mM ammonium acetateand extracted using dichloromethane. Our calibration curves ranged from 25 to 104 pg/mL. Excellent linearitywas obtained with correlation coefficient values between 0.9996 and 1.0000. The limit of detection (LOD) was5 pg/mL (S/N ≥ 3) and the retention time was 10 min. The limit of quantification (LOQ) was 25 pg/mL, andthe acceptance criteria was the rate of 98-103% (80-120% at levels up to 3×LOQ). The coefficient of variations(CV) was 2.8%. Accuracies determined from dust samples spiked with four different levels of NNK racurvesranged that from 25 to 104 pg/mL. Excellent linearity was obtained between 92.1% and 114%. The precisionof the method was acceptable (5% of CV). The recovery rates of the whole analytical procedure at low, medium,and high levels were 105.7-116.5% for NNK. The carry-over effects during LC-MS/MS analysis were notobserved for NNK. This manuscript summarizes the scientific evidence on the use of markers to measure ETS.

      더보기

      참고문헌 (Reference)

      1 J. Makin, 13 : 5-12, 1991

      2 C. -J. Hsieh, 12 : 1108-1117, 2010

      3 D. G. Cook, 52 : 1081-1094, 1997

      4 D. G. Cook, 53 : 884-893, 1998

      5 D. P. Strachan, 52 : 905-914, 1997

      6 M. W. Seong, 411 (411): 72-76, 2010

      7 J. P. Winickoff, 123 : e74-e79, 2009

      8 A. Burton, 119 : A70-A74, 2011

      9 L. Gatzke-Kopp, 38 : 255-269, 2007

      10 G. E. Matt, 13 : 29-37, 2004

      1 J. Makin, 13 : 5-12, 1991

      2 C. -J. Hsieh, 12 : 1108-1117, 2010

      3 D. G. Cook, 52 : 1081-1094, 1997

      4 D. G. Cook, 53 : 884-893, 1998

      5 D. P. Strachan, 52 : 905-914, 1997

      6 M. W. Seong, 411 (411): 72-76, 2010

      7 J. P. Winickoff, 123 : e74-e79, 2009

      8 A. Burton, 119 : A70-A74, 2011

      9 L. Gatzke-Kopp, 38 : 255-269, 2007

      10 G. E. Matt, 13 : 29-37, 2004

      11 N. Ramirez, 1219 : 180-187, 2012

      12 H. Hongwei, 63 : 17-22, 2012

      13 W. O. Spitzer, 13 (13): 17-42, 1990

      14 D. Hoffmann, 14 : 767-790, 2001

      15 G. E. Matt, 119 : 1218-1226, 2011

      16 J. M. Yuan, 69 : 2990-2995, 2009

      17 S. S. Hecht, 11 : 559-603, 1998

      18 R. A. Jenkins, "The Chemistry of Environmental Tobacco Smoke: Composition and Measurement" Lewis Publisher 2000

      19 Lyon, "International Agency for Research on Cancer" 37 : 1-291, 1985

      20 Lyon, "International Agency for Research on Cancer" 83 : 1-1438, 2004

      21 "Food and Drug Administration"

      22 황상현, "Environmental tobacco smoke and children’s health" 대한소아과학회 55 (55): 35-41, 2012

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2016-01-01 평가 등재학술지 선정 (계속평가) KCI등재
      2015-12-01 평가 등재후보로 하락 (기타) KCI등재후보
      2011-02-28 학술지명변경 외국어명 : Analytuacl Science & Technology -> Analytical Science & Technology KCI등재
      2011-01-01 평가 등재 1차 FAIL (등재유지) KCI등재
      2009-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2007-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2004-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2003-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2002-01-01 평가 등재후보학술지 유지 (등재후보1차) KCI등재후보
      2000-07-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.24 0.24 0.2
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.22 0.2 0.393 0.05
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼