RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재 SCOPUS

      의료 영상진단용 초음파 어레이 센서의 최적설계 및 특성해석 = Optimal Design and Analysis of a Medical Imaging Ultrasonic Array Sensor

      한글로보기

      https://www.riss.kr/link?id=A101069623

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      The performance of an ultrasonic array sensor is determined by the properties of constituent materials and the effects of many structural parameters. In this study, with the finite element method, variation of the performances of an ultrasonic array s...

      The performance of an ultrasonic array sensor is determined by the properties of constituent materials and the effects of many structural parameters. In this study, with the finite element method, variation of the performances of an ultrasonic array sensor was analyzed in relation to its structural variables. Based on the analysis result, the structure of the ultrasonic array sensor was optimized to provide the highest sensitivity while satisfying such requirements as fractional bandwidth, center frequency and -20 dB pulse length. The optimization was carried out with the SQP-PD method for a target function composed of the ultrasonic array sensor performance. The optimized ultrasonic array sensor satisfied all the required specifications to be applicable to medical imaging diagnosis. The design technology in this paper can be utilized for other ultrasonic array sensors of a similar structure.

      더보기

      국문 초록 (Abstract)

      초음파 어레이 센서의 성능은 구성 불성과 많은 구소 변수들에 의해 결정된다. 본 연구에서는 유한 요소해석을 통하여 구조적인 변화에 따른 초음파 어레이 센서의 성능변화를 해석하였다. ...

      초음파 어레이 센서의 성능은 구성 불성과 많은 구소 변수들에 의해 결정된다. 본 연구에서는 유한 요소해석을 통하여 구조적인 변화에 따른 초음파 어레이 센서의 성능변화를 해석하였다. 해석 결과를 기초로 하여 초음파 어레이 센서가 주파수 대역폭, 중심 주파수 그리고 -20 dB pulse length와 같은 요구 사항을 모두 만족시키며 최대의 감도를 가지도록 구조를 최적화하였다. 최적화 방법으로는 초음파 어레이 센서의 성능을 목적 함수로 하는 SQP-PD 방법을 사용하였다. 최적화된 초음파 어레이 센서는 의료 영상 진단에 적용되기 위한 모든 요구 조건을 만족하였으며, 본 설계 기술은 유사한 형태의 다른 배열형 초음파 센서에 응용 가능하다

      더보기

      참고문헌 (Reference)

      1 K. R. Erikson, "Ultrasound in medicine-a review" 21 : 144-170, 1974

      2 J.Ylitalo, "Synthetic aperture ultrasound imaging using convex array" 1337-1340, 1995

      3 R. J. Freund, "Regression analysis: Statistical modeling of a response variable" Academic Press 1998

      4 S. C. Wooh, "Optimum beam steering of linear phased arrays" 29 : 245-265, 1999

      5 R. E. Miller, "Optimization: foundations and applications" John Wiley & Sons 2000

      6 D. A. Pierre, "Optimization theory with applications" Dover Publications 1986

      7 K.J.Kang, "Optimization of structural variables of a flextensional transducer by the statistical multiple regression analysis method" 114 (114): 1454-1461, 2003

      8 A. D. Belegudu, "Optimization concept and application in engineering,Chap.5" Prentice Hall 1999

      9 J.Larson, "Non-ideal radiations in phased array transducers" 673-684, 1984

      10 D. J. Powell, "Incremental ‘Model-build-test’Validation Exercise for a 1-D Biomedical Ultrasonic Imaging Array" 1669-1674, 1997

      1 K. R. Erikson, "Ultrasound in medicine-a review" 21 : 144-170, 1974

      2 J.Ylitalo, "Synthetic aperture ultrasound imaging using convex array" 1337-1340, 1995

      3 R. J. Freund, "Regression analysis: Statistical modeling of a response variable" Academic Press 1998

      4 S. C. Wooh, "Optimum beam steering of linear phased arrays" 29 : 245-265, 1999

      5 R. E. Miller, "Optimization: foundations and applications" John Wiley & Sons 2000

      6 D. A. Pierre, "Optimization theory with applications" Dover Publications 1986

      7 K.J.Kang, "Optimization of structural variables of a flextensional transducer by the statistical multiple regression analysis method" 114 (114): 1454-1461, 2003

      8 A. D. Belegudu, "Optimization concept and application in engineering,Chap.5" Prentice Hall 1999

      9 J.Larson, "Non-ideal radiations in phased array transducers" 673-684, 1984

      10 D. J. Powell, "Incremental ‘Model-build-test’Validation Exercise for a 1-D Biomedical Ultrasonic Imaging Array" 1669-1674, 1997

      11 N. Felix, "Experimental investigation of cross-coupling and its influence on the elementary radiation pattern in 1D ultrasound arrays" 1053-1056, 1999

      12 R. O. Kuehl, "Design of experiments: Statistical principles of research design and analysis" Duxbury Press 2000

      13 R.E.McKeighe, "Design Guidelines for Medical Ultrasonic Arrays" 2-18, 1998

      14 강국진, "Class IV Flextensional 트랜스듀서의 주파수 특성 변화에 관한 연구" 18 (18): 67-73, 1999

      15 J.A.Jensen, "Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers" 39 : 262-267, 1992

      16 S. W. Smith, "Angular response of piezoelectric elements in linear phased array ultrasound scanners" 26 : 185-191, 1979

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2026 평가예정 재인증평가 신청대상 (재인증)
      2020-01-01 평가 등재학술지 유지 (재인증) KCI등재
      2017-01-01 평가 등재학술지 유지 (계속평가) KCI등재
      2013-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2010-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2008-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2006-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2004-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2001-07-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      1999-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.23 0.23 0.22
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.2 0.18 0.398 0.07
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼