      Removal of PM2.5 entering through the ventilation duct in an automobile using a carbon fiber ionizer-assisted cabin air filter

      한글로보기

      https://www.riss.kr/link?id=A107577409

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      <P><B>Abstract</B></P><P>This study evaluated the charging characteristics of a carbon fiber ionizer for PM2.5 and carried out particle capture laboratory tests after an ionizer was installed upstream of the media of an e...

      <P><B>Abstract</B></P><P>This study evaluated the charging characteristics of a carbon fiber ionizer for PM2.5 and carried out particle capture laboratory tests after an ionizer was installed upstream of the media of an electret cabin air filter. When the ion concentration per particle (<I>N</I><SUB><I>i</I></SUB>) of the carbon fiber charger was 10<SUP>6</SUP>ions/cm<SUP>3</SUP>, the average charge numbers for each particle were 1.54, 0.88, and 0.49 at 0.6, 1.2, and 1.8m/s of face velocity, respectively (the particle charging times, <I>τ</I>, were 167, 83, and 56ms, respectively). For these face velocities, the PM2.5 removal efficiencies of the filter media were 69.3%, 65.2% and 62.2%, respectively, but increased to 80.4%, 71.2% and 65.5%, respectively, when the ionizer was turned on. The carbon fiber ionizer was then installed in front of an electret cabin filter in the air conditioning system of an automobile, after which field tests were performed at a roadside area. For the same <I>N</I><SUB><I>i</I></SUB><I>τ</I> used in the lab-scale tests, the effects of the carbon fiber ionizer on increasing PM2.5 %Reduction were mild as 9.4%, 4.0%, and 2.8% when the flow rates were at the second, fourth, and sixth levels, respectively (the face velocities were 0.6, 1.2, and 1.8m/s, respectively). The PM2.5 %Reduction can be substantially increased by 20–21%, for a higher value of <I>N</I><SUB><I>i</I></SUB><I>τ</I> (=1.0×10<SUP>8</SUP>ions s/cm<SUP>3</SUP>), which is realized by increasing the power consumption of the carbon fiber ionizer.</P>

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼