1 최진욱, "임플랜트 지대주 나사의 텅스텐 카바이드/탄소 코팅이 전하중에 미치는 영향에 관한 연구" 대한치과보철학회 44 (44): 229-242, 2006
2 Kim KS, "Variation in the total lengths of abutment/implant assemblies generated with a function of applied tightening torque in external and internal implant-abutment connection" 22 : 834-839, 2011
3 Kano SC, "Use of base metal casting alloys for implant framework: marginal accuracy analysis" 12 : 337-343, 2004
4 Lewis S, "The restoration of improperly inclined osseointegrated implants" 4 : 147-152, 1989
5 Sutter F, "The new restorative concept of the ITI dental implant system: design and engineering" 13 : 409-431, 1993
6 Lewis SG, "The UCLA abutment: a four-year review" 68 : 509-515, 1992
7 Lee JJ, "Surface roughness changes caused by the galvanic corrosion between a titanium abutment and base metal alloy" 대한치과보철학회 49 (49): 65-72, 2011
8 Shigley JE, "Standard Handbook of Machine Designs" McGraw-Hill 16-23, 1986
9 Simon RL, "Single implant-supported molar and premolar crowns: a ten-year retrospective clinical report" 90 : 517-521, 2003
10 Becker W, "Replacement of maxillary and mandibular molars with single endosseous implant restorations: a retrospective study" 74 : 51-55, 1995
1 최진욱, "임플랜트 지대주 나사의 텅스텐 카바이드/탄소 코팅이 전하중에 미치는 영향에 관한 연구" 대한치과보철학회 44 (44): 229-242, 2006
2 Kim KS, "Variation in the total lengths of abutment/implant assemblies generated with a function of applied tightening torque in external and internal implant-abutment connection" 22 : 834-839, 2011
3 Kano SC, "Use of base metal casting alloys for implant framework: marginal accuracy analysis" 12 : 337-343, 2004
4 Lewis S, "The restoration of improperly inclined osseointegrated implants" 4 : 147-152, 1989
5 Sutter F, "The new restorative concept of the ITI dental implant system: design and engineering" 13 : 409-431, 1993
6 Lewis SG, "The UCLA abutment: a four-year review" 68 : 509-515, 1992
7 Lee JJ, "Surface roughness changes caused by the galvanic corrosion between a titanium abutment and base metal alloy" 대한치과보철학회 49 (49): 65-72, 2011
8 Shigley JE, "Standard Handbook of Machine Designs" McGraw-Hill 16-23, 1986
9 Simon RL, "Single implant-supported molar and premolar crowns: a ten-year retrospective clinical report" 90 : 517-521, 2003
10 Becker W, "Replacement of maxillary and mandibular molars with single endosseous implant restorations: a retrospective study" 74 : 51-55, 1995
11 Siamos G, "Relationship between implant preload and screw loosening on implant-supported prostheses" 28 : 67-73, 2002
12 Cavazos E, "Preventing loosening of implant abutment screws" 75 : 566-569, 1996
13 Jemt T, "Osseointegrated implants for single tooth replacement: a 1-year report from a multicenter prospective study" 6 : 29-36, 1991
14 White GE, "Osseointegrated dental technology" Quintessence 70-83, 1993
15 Schwarz MS, "Mechanical complications of dental implants" 11 : 156-158, 2000
16 Jorne′us L, "Loads and designs of screw joints for single crowns supported by osseointegrated implants" 7 : 353-359, 1992
17 Quek HC, "Load fatigue performance of four implant-abutment interface designs: effect of torque level and implant system" 23 : 253-262, 2008
18 Richter EJ, "In vivo vertical forces on implants" 10 : 99-108, 1995
19 Mericske-Stern R, "In vivo measurements of some functional aspects with mandibular fixed prostheses supported by implants" 7 : 153-161, 1996
20 Geis-Gerstorfer J, "In vitro substance loss due to galvanic corrosion in Ti implant/Ni-Cr supraconstruction systems" 4 : 119-123, 1989
21 Jemt T, "Failures and complications in 127 consecutively placed fixed partial prostheses supported by Branemark implants: from prosthetic treatment to first annual checkup" 7 : 40-44, 1992
22 김경남, "Electrochemical properties of suprastructures galvanically coupled to a titanium implant" 70B : 318-331, 200408
23 Ricciardi Coppede A, "Effect of repeated torque/mechanical loading cycles on two different abutment types in implants with internal tapered connections: an in vitro study" 20 : 624-632, 2009
24 Weiss EI, "Effect of repeated closures on opening torque values in seven abutment-implant systems" 84 : 194-199, 2000
25 Hulterstrom M, "Cobalt-chromium as a framework material in implant-supported fixed prostheses: a preliminary report" 6 : 475-480, 1991
26 Goodacre CJ, "Clinical complications with implants and implant prostheses" 90 : 121-132, 2003
27 Carotenuto G, "Characterization of the interface between prefabricated gold copings and cast dental alloy in implant restorations" 10 : 131-138, 1999
28 Im SM, "Biomechanical considerations for the screw of implant prosthesis: A literature review" 대한치과보철학회 48 (48): 61-68, 2010
29 Wataha JC, "Biocompatibility of dental casting alloys: a review" 83 : 223-234, 2000
30 O’Brien WJ, "Base metal casting alloys, In Dental material and their selection" Quintessence 259-268, 1997
31 Dailey B, "Axial displacement of abutments into implants and implant replicas, with the tapered cone-screw internal connection, as a function of tightening torque" 24 : 251-256, 2009
32 Norton MR, "An in vitro evaluation of the strength of a 1-piece and 2-piece conical abutment joint in implant design" 11 : 458-464, 2000
33 Lim JH, "A study on the photoelastic analysis of stresses induced by the connection modalities between natural tooth abutment and dental implant" 4 : 141-151, 1992
34 Kang YM, "A study on the abutment screw loosening of dental implants" 34 : 1-14, 1996
35 Artzi Z, "A screw lock for single-tooth implant superstructures" 130 : 677-682, 1999
36 Adell R, "A 15-year study of osseointegrated implants in the treatment of the edentulous jaw" 10 : 387-416, 1981