RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재

      Annual Report of the Korean Association of External Quality Assessment Service on Transfusion Medicine (2020)

      한글로보기

      https://www.riss.kr/link?id=A107957848

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      This report summarizes the 2020 survey results of the external quality assessment (EQA) scheme for the Transfusion Medicine Program (TMP) in Korea. Proficiency testing materials were prepared at Asan Medical Center for biannual distribution to the par...

      This report summarizes the 2020 survey results of the external quality assessment (EQA) scheme for the Transfusion Medicine Program (TMP) in Korea. Proficiency testing materials were prepared at Asan Medical Center for biannual distribution to the participating laboratories. The accuracy rates and number of participants for the 10 survey items were as follows: ABO typing, 99.6%–99.9% (n=890/897); RhD typing, 99.7%–100.0% (n=877/885); crossmatching, 94.0%–99.1% (n=771/780); ABO subgroup typing, 95.2%–98.4% (n=62/63); Rh CcEe antigen, 100% (n=56/58); weak D test, 92.8%–98.4% (n=250/252); antibody screening, 99.7%–100.0% (n=327/329); direct antiglobulin test (DAT) using a polyspecific reagent, 97.2%–99.7% (n=283/286); DAT using anti-immunoglobulin-G monospecific reagent, 88.7%–100.0% (n=71/71); DAT using anti-C3d monospecific reagent, 97.2%–100.0% (n=70/72); antibody identification, 68.9%–100% (n=135/135); and ABO antibody titration, 94.3%–100.0% (n=140/142). As compared to last year’s EQA report, there was an average increase of 5.1% in the number of participating laboratories across the 10 survey items, with the ABO subgroup typing and weak D test showing the highest increase of 8.6%. Although the overall results were excellent, only 68.9% of the participants precisely detected samples with anti-C and anti-e in the EQA conducted in the first half of 2020. The 2020 EQA scheme for TMP has contributed to the improvement and maintenance of the participating laboratories in the program.

      더보기

      참고문헌 (Reference)

      1 Er LS, "Technical manual" American Assocation of Blood Banks 389-428, 2020

      2 Yang JJ, "Retrospection of anti-blood group antibody proficiency testing data using the geometric mean and standard deviation" 153 : 530-536, 2020

      3 AuBuchon JP, "Reducing the variation in performance of antibody titrations" 132 : 1194-1201, 2008

      4 Bachegowda LS, "Impact of uniform methods on interlaboratory antibody titration variability: antibody titration and uniform methods" 141 : 131-138, 2017

      5 강선주, "Comparison of ABO Antibody Titers on the Basis of the Antibody Detection Method Used" 대한진단검사의학회 34 (34): 300-306, 2014

      6 John Jeongseok Yang, "Annual Report of the Korean Association of External Quality Assessment Service on Transfusion Medicine (2019)" 대한임상검사정도관리협회 42 (42): 112-120, 2020

      7 Yousun Chung, "A Pilot Project for Expansion of the External Quality Assessment Program in Transfusion Medicine: Extended Antigen Typing" 대한임상검사정도관리협회 43 (43): 87-93, 2021

      1 Er LS, "Technical manual" American Assocation of Blood Banks 389-428, 2020

      2 Yang JJ, "Retrospection of anti-blood group antibody proficiency testing data using the geometric mean and standard deviation" 153 : 530-536, 2020

      3 AuBuchon JP, "Reducing the variation in performance of antibody titrations" 132 : 1194-1201, 2008

      4 Bachegowda LS, "Impact of uniform methods on interlaboratory antibody titration variability: antibody titration and uniform methods" 141 : 131-138, 2017

      5 강선주, "Comparison of ABO Antibody Titers on the Basis of the Antibody Detection Method Used" 대한진단검사의학회 34 (34): 300-306, 2014

      6 John Jeongseok Yang, "Annual Report of the Korean Association of External Quality Assessment Service on Transfusion Medicine (2019)" 대한임상검사정도관리협회 42 (42): 112-120, 2020

      7 Yousun Chung, "A Pilot Project for Expansion of the External Quality Assessment Program in Transfusion Medicine: Extended Antigen Typing" 대한임상검사정도관리협회 43 (43): 87-93, 2021

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2024 평가예정 재인증평가 신청대상 (재인증)
      2021-01-01 평가 등재학술지 선정 (계속평가) KCI등재
      2019-12-01 학술지명변경 한글명 : Journal of Laboratory Medicine And Quality Assurance -> Laboratory Medicine and Quality Assurance KCI등재후보
      2019-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼