<P>A common-mode (CM) active filter was designed in a compact package to suppress CM conducted emissions at a switching mode power supply (SMPS). Based on the analytical expressions considering both stability and performance, the design and opti...
http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
https://www.riss.kr/link?id=A107515198
2015
-
SCI,SCIE,SCOPUS
학술저널
660-671(12쪽)
0
상세조회0
다운로드다국어 초록 (Multilingual Abstract)
<P>A common-mode (CM) active filter was designed in a compact package to suppress CM conducted emissions at a switching mode power supply (SMPS). Based on the analytical expressions considering both stability and performance, the design and opti...
<P>A common-mode (CM) active filter was designed in a compact package to suppress CM conducted emissions at a switching mode power supply (SMPS). Based on the analytical expressions considering both stability and performance, the design and optimization rules for the proposed active filter have been presented. After verifying its performance by measurements using vector network analysis, the proposed filter was installed in a 200-W SMPS board with 64 and 110 kHz switching frequencies, demonstrating its usefulness by experiments. The performance degradation due to the magnetic saturation and the AEF grounding impedance was also analyzed and investigated.</P>