      OPTIMIZATION OF THE RESERVE-TYPE DISTRIBUTOR FOR R410A AIR CONDITIONER

      한글로보기

      https://www.riss.kr/link?id=A104423838

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Mal-distribution of refrigerant in a cross-flow type evaporator with parallel paths is very important, which can lead to a loss of heat exchanger capacity to 25%. Distributors are used to balance the two-phase refrigerant distributions in each path. A...

      Mal-distribution of refrigerant in a cross-flow type evaporator with parallel paths is very important, which can lead to a loss of heat exchanger capacity to 25%. Distributors are used to balance the two-phase refrigerant distributions in each path. Apart from the structural factors, there are other factors influencing the performance of distributor greatly. In this paper, influences of several nonstructural factors on reservoir distributor are investigated experimentally under varied working conditions. The inlet tube configuration, installation orientation and capillary tube length are also studied. One experiment apparatus is developed to measure the refrigerant mass flow rate and the quality based on R410A air conditioner. It is found that influence caused by inlet tube before the distributor is small. The average STD is only 2.76%. Influence caused by orientation is broad. The average STD is less than 9% on the orientation of 15°. On the orientation of 90°, STDs of different conditions are all more than 40%. For orientation, mass flow rate sensitivity is larger than quality sensitivity. Capillary tubes with different length can be used to adjust distribution. Average STD with sizable capillary length difference is 9.47%. It means that only small mal-distribution can be adjusted by using different-length capillary tubes. Capillary tube length sensitivity increases with the increase of difference between outlet tubes or the decrease of average length of outlet tubes.

      더보기

      참고문헌 (Reference)

      1 P. Fei, "efrigerant distribution in the inlet header of plate evaporators" SAE

      2 Y. Gao, "Research for performance of liquid distributor" 2 : 12-14, 2002

      3 S. Yoshioka, "Performance evaluation and optimization of a refrigerant distributor for air conditioner" 2 : 603-609, 2007

      4 E. W. Lemmon, "NIST reference °uid thermodynamic and transport properties — REFPROP version 8.0 user's guide"

      5 H. Cho, "Mass °ow rate distribution and phase separation of R-22 in multimicrochannel tubes under adiabatic condition" 527-533, 2003

      6 N. Kattan, "Flow boiling in horizontal tubes: Part 1-development of a diabatic C two-phase °ow pattern map" 120 : 140-147, 1998

      7 M. A. Fay, "E®ect of conical distributors on evaporator and system performance"

      8 G. Li, "Evaluating the performance of refrigerant °ow distributors"

      9 QING HAN, "EXPERIMENTAL AND CFD INVESTIGATION OF R410A DISTRIBUTORS FOR AIR CONDITIONER" 대한설비공학회 22 (22): 1-11, 2014

      10 A. Aziz, "Distribution of two-phase °ow in a distributor" 7 : 41-55, 2012

      1 P. Fei, "efrigerant distribution in the inlet header of plate evaporators" SAE

      2 Y. Gao, "Research for performance of liquid distributor" 2 : 12-14, 2002

      3 S. Yoshioka, "Performance evaluation and optimization of a refrigerant distributor for air conditioner" 2 : 603-609, 2007

      4 E. W. Lemmon, "NIST reference °uid thermodynamic and transport properties — REFPROP version 8.0 user's guide"

      5 H. Cho, "Mass °ow rate distribution and phase separation of R-22 in multimicrochannel tubes under adiabatic condition" 527-533, 2003

      6 N. Kattan, "Flow boiling in horizontal tubes: Part 1-development of a diabatic C two-phase °ow pattern map" 120 : 140-147, 1998

      7 M. A. Fay, "E®ect of conical distributors on evaporator and system performance"

      8 G. Li, "Evaluating the performance of refrigerant °ow distributors"

      9 QING HAN, "EXPERIMENTAL AND CFD INVESTIGATION OF R410A DISTRIBUTORS FOR AIR CONDITIONER" 대한설비공학회 22 (22): 1-11, 2014

      10 A. Aziz, "Distribution of two-phase °ow in a distributor" 7 : 41-55, 2012

      11 J. K. Lee, "Distribution of two-phase annular °ow at header-channel junctions" 28 : 217-222, 2004

      12 M. Nakayama, "Development of a refrigerant twophase °ow distributor for a room air conditioner, Int" 313-320, 2000

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2013-01-01 평가 등재 1차 FAIL (등재유지) KCI등재
      2010-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2009-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2008-01-01 평가 등재후보학술지 유지 (등재후보1차) KCI등재후보
      2006-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.56 0.56 0.48
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.4 0.34 0.535 0.11
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼