RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재 SCOPUS

      안와파열골절 급성기의 CT영상을 이용한 계측학적인 연구 = Measurement Analytical Study of Computed Tomography of the Orbital Structure in Acute Blow-out Fracture

      한글로보기

      https://www.riss.kr/link?id=A104554652

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Purpose: Blow-out fracture is one of the most common fractures in facial trauma. It is diagnosed by Computed Tomography(CT) scan, which is considered as the most effective diagnostic tool. Since, the Picture Archiving Communication System(PACS) has been provided recently to many hospitals, doctors are more familiar with imaging software of PACS. Because this software has many useful measuring tools, doctors can measure orbital structure easily and make a plan for treatment with its data. Therefore, authors intended to analyze the data of orbital structure measured with PACS imaging software and evaluate its usefulness. Methods: The charts and CT images of 100 patients, which were 50 patients with medial wall fracture and 50 patients with floor fracture, were reviewed. Patients were selected by pre-determined criteria and their CT images were measured with image software of PACS. 'Extraocular muscle thickness', 'Defect ratio'(ratio of defect area to normal area) and 'Globe position index' were measured and analyzed statistically.Results: The thickness of inferior rectus muscle and medial rectus muscle was simultaneously increased in acute-stage of blow-out fracture. The medial rectus muscle was more thickened in medial wall fracture and inferior rectus was more thickened in floor fracture, respectively. In acute blow-out fracture, globe position is exophthalmic rather than enophthalmic. Especially in floor fracture, numerical value summed up thickness of all extraocular muscle is correlated to the defect ratio and globe position index. Conclusion: Clinicians can decide globe position or presume defect ratio in inferior wall fracture by measurement of CT image in acute blow-out fracture using PACS.
      번역하기

      Purpose: Blow-out fracture is one of the most common fractures in facial trauma. It is diagnosed by Computed Tomography(CT) scan, which is considered as the most effective diagnostic tool. Since, the Picture Archiving Communication System(PACS) has be...

      Purpose: Blow-out fracture is one of the most common fractures in facial trauma. It is diagnosed by Computed Tomography(CT) scan, which is considered as the most effective diagnostic tool. Since, the Picture Archiving Communication System(PACS) has been provided recently to many hospitals, doctors are more familiar with imaging software of PACS. Because this software has many useful measuring tools, doctors can measure orbital structure easily and make a plan for treatment with its data. Therefore, authors intended to analyze the data of orbital structure measured with PACS imaging software and evaluate its usefulness. Methods: The charts and CT images of 100 patients, which were 50 patients with medial wall fracture and 50 patients with floor fracture, were reviewed. Patients were selected by pre-determined criteria and their CT images were measured with image software of PACS. 'Extraocular muscle thickness', 'Defect ratio'(ratio of defect area to normal area) and 'Globe position index' were measured and analyzed statistically.Results: The thickness of inferior rectus muscle and medial rectus muscle was simultaneously increased in acute-stage of blow-out fracture. The medial rectus muscle was more thickened in medial wall fracture and inferior rectus was more thickened in floor fracture, respectively. In acute blow-out fracture, globe position is exophthalmic rather than enophthalmic. Especially in floor fracture, numerical value summed up thickness of all extraocular muscle is correlated to the defect ratio and globe position index. Conclusion: Clinicians can decide globe position or presume defect ratio in inferior wall fracture by measurement of CT image in acute blow-out fracture using PACS.

      더보기

      참고문헌 (Reference)

      1 Lutzemberger L, "Volumetric analysis of CT orbital images" 36 : 661-, 1998

      2 Chun HJ, "The survey on korean PACS in 2004" 10 : 71-, 2004

      3 Kim DH, "The measurement of size of human extraocular muscles and their changes in thyroid associated ophthalmopathy in Korea" 42 : 321-, 2001

      4 Manson PN, "Studies on enophthalmos II The measurement of orbital injuries and their treatment by quantitative computed tomography" 1986

      5 Jin HR, "Relationship between the extent of fracture and the degree of enophthalmos in isolated blow-out fractures of the medial orbital wall" 58 : 617-, 2000

      6 Raskin EM, "Prediction of late enophthalmos by volumetric analysis of orbital fractures" 4 : 19-, 1998

      7 Lee JG, "Orbital volume change measured by computed tomography in blow out fracture" 27 : 437-, 2000

      8 Chau A, "Orbital development in Hong Kong Chinese subjects" 24 : 436-, 2004

      9 Lee JS, "Normative measurements of Korean orbital structures revealed by computed tomography" 79 : 197-, 2001

      10 Kim IT, "Normal range of exophthalmos values on orbit computed tomography in Koreans" 215 : 156-, 2001

      1 Lutzemberger L, "Volumetric analysis of CT orbital images" 36 : 661-, 1998

      2 Chun HJ, "The survey on korean PACS in 2004" 10 : 71-, 2004

      3 Kim DH, "The measurement of size of human extraocular muscles and their changes in thyroid associated ophthalmopathy in Korea" 42 : 321-, 2001

      4 Manson PN, "Studies on enophthalmos II The measurement of orbital injuries and their treatment by quantitative computed tomography" 1986

      5 Jin HR, "Relationship between the extent of fracture and the degree of enophthalmos in isolated blow-out fractures of the medial orbital wall" 58 : 617-, 2000

      6 Raskin EM, "Prediction of late enophthalmos by volumetric analysis of orbital fractures" 4 : 19-, 1998

      7 Lee JG, "Orbital volume change measured by computed tomography in blow out fracture" 27 : 437-, 2000

      8 Chau A, "Orbital development in Hong Kong Chinese subjects" 24 : 436-, 2004

      9 Lee JS, "Normative measurements of Korean orbital structures revealed by computed tomography" 79 : 197-, 2001

      10 Kim IT, "Normal range of exophthalmos values on orbit computed tomography in Koreans" 215 : 156-, 2001

      11 Nkenke E, "Hertel exophthalmometry versus computed tomography and optical 3D imaging for the determination of the globe position in zygomatic fractures" 33 : 125-, 2004

      12 Finkle DR, "Comparison of the diagnostic methods used in maxillofacial Trauma" 1985

      13 Choi JY, "CT findings of orbital blow out fracture" 38 : 229-, 1998

      14 Ploder O, "A computer- based method for calculation of orbital floor fractures from coronal computed tomography scans" 59 : 1437-, 2001

      더보기

      동일학술지(권/호) 다른 논문

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2012-01-15 학술지명변경 한글명 : 대한성형외과 학회지 -> Archives of Plastic Surgery
      외국어명 : Journal of The Korean Society of Plastic and Reconstructive Surgeons -> Archives of Plastic Surgery
      KCI등재
      2011-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2009-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2007-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2004-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2003-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2001-07-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.12 0.12 0.12
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.12 0.11 0.335 0.02
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼