<P>The Korea Basic Science Institute (KBSI) has targeted a 3.1 T superconducting magnet system to be used in a K120 superconducting cyclotron as one of the next cyclotron for medical application in the Korea Institute of Radiological and Medical...
http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
https://www.riss.kr/link?id=A107585942
2010
-
SCOPUS,SCIE
학술저널
806-809(4쪽)
0
상세조회0
다운로드다국어 초록 (Multilingual Abstract)
<P>The Korea Basic Science Institute (KBSI) has targeted a 3.1 T superconducting magnet system to be used in a K120 superconducting cyclotron as one of the next cyclotron for medical application in the Korea Institute of Radiological and Medical...
<P>The Korea Basic Science Institute (KBSI) has targeted a 3.1 T superconducting magnet system to be used in a K120 superconducting cyclotron as one of the next cyclotron for medical application in the Korea Institute of Radiological and Medical Sciences (KIRAMS). The main superconducting magnet should be designed to accelerate various ions for the magnetic bending limit up to 120 MeV. Several ancillary requirements such as background field, space restriction due to ion beam line, and cryostat structure need technical attention. The conceptual design activities of main superconducting magnet system are completed. A quarter-scaled prototype is designed and fabricated in order to confirm the feasibility of our design. The design and fabrication of prototype superconducting magnet system is described in this paper. Also, the detail cryogenic cooling and cryostat structure are presented.</P>