      고속도로 터널 내 실내오염물질 농도의 일변화 분포특성 = Distribution of Daily Change of Concentration of Contaminants in Expressway Tunnels

      한글로보기

      https://www.riss.kr/link?id=A103045417

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      The study inspected air in expressway tunnels to verify contaminants and to collect data of ventilation ON:The subject was Suri Tunnel (in direction of Ilsan) in Gunpo Gyeonggi-do and Jungnyeong Tunnel (in direction of Chuncheon) at Danyang Chungbuk. ...

      The study inspected air in expressway tunnels to verify contaminants and to collect data of ventilation ON:The subject was Suri Tunnel (in direction of Ilsan) in Gunpo Gyeonggi-do and Jungnyeong Tunnel (in direction of Chuncheon) at Danyang Chungbuk. Suri Tunnel (in the direction of Ilsan) with length of about 1,866 meters was likely to have plenty of contaminants because of many traffic (100,000 vehicles a day), and Jungnyeong Tunnel (in the direction of Chuncheon) had less traffic (6,000 to 10,000 vehicles a day) to be likely to have high contaminant because of long time contaminants in long tunnel). We were given material with help of Korean Expressway Corporation, and selected samples of tunnel according to daily traffic and length of tunnel. We had testing point at one place of top of check route (utility pipe conduit) about 100 meters inside from exit of the tunnel where remaining contaminants in the tunnel were likely to have high concentration to flow toward exit of the tunnel. Article 42 of law on road structure and facility (ventilation of the tunnel) specified testing and analysis of contaminants in the tunnel to mention carbon monoxide and nitrogen oxide: And, article 5 (keeping of indoor air quality) and article 6 (recommendation of indoor air quality) of law on structure and control of indoor air quality of multi-use facility was applied considering similarity of testing items of tunnel contaminants as well as contaminants of permission. The purpose of the study was to verify contaminants and to inspect daily change of indoor contaminants in the tunnel and to collect data of ventilation system ON and to give information on ventilation system ON and effective tunnel control.

      더보기

      목차 (Table of Contents)

      • Abstract
      • 1. 서론
      • 2. 연구방법
      • 3. 결과 및 고찰
      • 4. 결론
      • Abstract
      • 1. 서론
      • 2. 연구방법
      • 3. 결과 및 고찰
      • 4. 결론
      • REFERENCES
      더보기

      참고문헌 (Reference)

      1 김범석, "도로터널 내 공기질 측정과 Bag Filter를 이용한 미세먼지 제거 성능평가" 사단법인 한국터널지하공간학회 17 (17): 523-531, 2015

      2 Ministry of Land, infrastructure and Transport, "Yearbook of road bridge and tunnel statistics" 2014

      3 Kim, S, D., "Ventilation Effect of jet-fan in Tunnel" 21 (21): 1999

      4 Hong, S. C., "The study for change of air volume by the installation of jet fan in the subway natural ventilation for the improvement of air quality" The Graduate school of Kokuk University 2011

      5 Korea expressway corporation, "Status of highway with cars"

      6 Ministry of Construction & Transportation, "Statistical yearbook" 1996

      7 Korea research institute for human settlements, "Social overhead capital statistics & information yearbook" 2016

      8 National emergency management agency, "Roadway tunnels fire protection system installation and management guidelines"

      9 Moon, S. H., "An analysis on long tunnel ventilation and air guading using CFD" the University of Seoul 2009

      1 김범석, "도로터널 내 공기질 측정과 Bag Filter를 이용한 미세먼지 제거 성능평가" 사단법인 한국터널지하공간학회 17 (17): 523-531, 2015

      2 Ministry of Land, infrastructure and Transport, "Yearbook of road bridge and tunnel statistics" 2014

      3 Kim, S, D., "Ventilation Effect of jet-fan in Tunnel" 21 (21): 1999

      4 Hong, S. C., "The study for change of air volume by the installation of jet fan in the subway natural ventilation for the improvement of air quality" The Graduate school of Kokuk University 2011

      5 Korea expressway corporation, "Status of highway with cars"

      6 Ministry of Construction & Transportation, "Statistical yearbook" 1996

      7 Korea research institute for human settlements, "Social overhead capital statistics & information yearbook" 2016

      8 National emergency management agency, "Roadway tunnels fire protection system installation and management guidelines"

      9 Moon, S. H., "An analysis on long tunnel ventilation and air guading using CFD" the University of Seoul 2009

      더보기

      동일학술지(권/호) 다른 논문

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2026 평가예정 재인증평가 신청대상 (재인증)
      2020-01-01 평가 등재학술지 유지 (재인증) KCI등재
      2017-01-01 평가 등재학술지 유지 (계속평가) KCI등재
      2013-01-01 평가 등재 1차 FAIL (등재유지) KCI등재
      2010-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2007-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2006-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2005-09-23 학술지등록 한글명 : 한국생활환경학회지
      외국어명 : The Korean Society of Living Environmental System
      KCI등재후보
      2004-07-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.29 0.29 0.28
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.31 0.3 0.376 0.11
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼