RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재 SCOPUS

      Diagnostic accuracy of cone-beam computed tomography scans with high- and low-resolution modes for the detection of root perforations

      한글로보기

      https://www.riss.kr/link?id=A105224131

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Purpose: This study compared the diagnostic accuracy of cone-beam computed tomography (CBCT) scans obtained with 2 CBCT systems with high- and low-resolution modes for the detection of root perforations in endodontically treated mandibular molars. Ma...

      Purpose: This study compared the diagnostic accuracy of cone-beam computed tomography (CBCT) scans obtained with 2 CBCT systems with high- and low-resolution modes for the detection of root perforations in endodontically treated mandibular molars.
      Materials and Methods: The root canals of 72 mandibular molars were cleaned and shaped. Perforations measuring 0.2, 0.3, and 0.4 mm in diameter were created at the furcation area of 48 roots, simulating strip perforations, or on the external surfaces of 48 roots, simulating root perforations. Forty-eight roots remained intact (control group). The roots were filled using gutta-percha (Gapadent, Tianjin, China) and AH26 sealer (Dentsply Maillefer, Ballaigues, Switzerland). The CBCT scans were obtained using the NewTom 3G (QR srl, Verona, Italy) and Cranex 3D (Soredex, Helsinki, Finland) CBCT systems in high- and low-resolution modes, and were evaluated by 2 observers. The chisquare test was used to assess the nominal variables.
      Results: In strip perforations, the accuracies of low- and high-resolution modes were 75% and 83% for NewTom 3G and 67% and 69% for Cranex 3D. In root perforations, the accuracies of low- and high-resolution modes were 79% and 83% for NewTom 3G and was 56% and 73% for Cranex 3D.
      Conclusion: The accuracy of the 2 CBCT systems was different for the detection of strip and root perforations. The Cranex 3D had non-significantly higher accuracy than the NewTom 3G. In both scanners, the high-resolution mode yielded significantly higher accuracy than the low-resolution mode. The diagnostic accuracy of CBCT scans was not affected by the perforation diameter.

      더보기

      참고문헌 (Reference)

      1 de Chevigny C, "Treatment outcome in endodontics: the Toronto study-phase 4: initial treatment" 34 : 258-263, 2008

      2 Shemesh H, "The use of cone-beam computed tomography and digital periapical radiographs to diagnose root perforations" 37 : 513-516, 2011

      3 Patel S, "The potential applications of cone beam computed tomography in the management of endodontic problems" 40 : 818-830, 2007

      4 Skidmore AE, "Root canal morphology of the human mandibular first molar" 32 : 778-784, 1971

      5 Grondahl HG, "Radiographic manifestations of periapical inflammatory lesions" 8 : 55-67, 2004

      6 Gang Li, "Patient radiation dose and protection from cone-beam computed tomography" 대한영상치의학회 43 (43): 63-69, 2013

      7 Ball RL, "Intraoperative endodontic applications of cone-beam computed tomography" 39 : 548-557, 2013

      8 Venskutonis T, "Influence of voxel size on the diagnostic ability of cone-beam computed tomography to evaluate simulated root perforations" 29 : 151-159, 2013

      9 Liedke GS, "Influence of voxel size in the diagnostic ability of cone beam tomography to evaluate simulated external root resorption" 35 : 233-235, 2009

      10 Spin-Neto R, "Impact of voxel size variation on CBCT-based diagnostic outcome in dentistry: a systematic review" 26 : 813-820, 2013

      1 de Chevigny C, "Treatment outcome in endodontics: the Toronto study-phase 4: initial treatment" 34 : 258-263, 2008

      2 Shemesh H, "The use of cone-beam computed tomography and digital periapical radiographs to diagnose root perforations" 37 : 513-516, 2011

      3 Patel S, "The potential applications of cone beam computed tomography in the management of endodontic problems" 40 : 818-830, 2007

      4 Skidmore AE, "Root canal morphology of the human mandibular first molar" 32 : 778-784, 1971

      5 Grondahl HG, "Radiographic manifestations of periapical inflammatory lesions" 8 : 55-67, 2004

      6 Gang Li, "Patient radiation dose and protection from cone-beam computed tomography" 대한영상치의학회 43 (43): 63-69, 2013

      7 Ball RL, "Intraoperative endodontic applications of cone-beam computed tomography" 39 : 548-557, 2013

      8 Venskutonis T, "Influence of voxel size on the diagnostic ability of cone-beam computed tomography to evaluate simulated root perforations" 29 : 151-159, 2013

      9 Liedke GS, "Influence of voxel size in the diagnostic ability of cone beam tomography to evaluate simulated external root resorption" 35 : 233-235, 2009

      10 Spin-Neto R, "Impact of voxel size variation on CBCT-based diagnostic outcome in dentistry: a systematic review" 26 : 813-820, 2013

      11 Davies J, "Effective doses from cone beam CT investigation of the jaws" 41 : 30-36, 2012

      12 Zahra Dalili, "Diagnostic value of two modes of cone-beam computed tomography in evaluation of simulated external root resorption: an in vitro study" 대한영상치의학회 42 (42): 19-24, 2012

      13 Tsesis I, "Diagnosis and treatment of accidental root perforations" 13 : 95-107, 2006

      14 Menezes RF, "Detection of vertical root fractures in endodontically treated teeth in the absence and in the presence of metal post by cone-beam computed tomography" 16 : 48-, 2016

      15 Patel S, "Detection of periapical bone defects in human jaws using cone beam computed tomography and intraoral radiography" 42 : 507-515, 2009

      16 Cheng JG, "Detection accuracy of proximal caries by phosphor plate and cone-beam computerized tomography images scanned with different resolutions" 16 : 1015-1021, 2012

      17 Eskandarloo A, "Comparison of cone-beam computed tomography with intraoral photostimulable phosphor imaging plate for diagnosis of endodontic complications: a simulation study" 114 : e54-e61, 2012

      18 Naitoh M, "Comparison between cone-beam and multislice computed tomography depicting mandibular neurovascular canal structures" 109 : 25-31, 2010

      19 Khojastepour L, "Assessment of root perforation within simulated internal resorption cavities using cone-beam computed tomography" 41 : 1520-1523, 2015

      20 Ingle JI, "A standardized endodontic technique utilizing newly designed instruments and filling materials" 14 : 83-91, 1961

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2019-03-27 학회명변경 한글명 : 대한구강악안면방사선학회 -> 대한영상치의학회 KCI등재
      2012-04-16 학술지명변경 한글명 : 대한구강악안면방사선학회지 -> Imaging Science in Dentistry KCI등재
      2011-03-29 학술지명변경 외국어명 : Korean Journal of Oral and Maxillofacial Radiology -> Imaging Science in Dentistry KCI등재
      2010-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2008-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2006-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2003-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2002-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2000-07-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.12 0.12 0.11
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.11 0.12 0.217 0.02
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼