RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      A Robust Wearable Point‐of‐Care CNT‐Based Strain Sensor for Wirelessly Monitoring Throat‐Related Illnesses

      한글로보기

      https://www.riss.kr/link?id=O106989560

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Point‐of‐care testing (POC) has the ability to detect chronic and infectious diseases early or at the time of occurrence and provide a state‐of‐the‐art personalized healthcare system. Recently, wearable and flexible sensors have been employed to analyze sweat, glucose, blood, and human skin conditions. However, a flexible sensing system that allows for the real‐time monitoring of throat‐related illnesses, such as salivary parotid gland swelling caused by flu and mumps, is necessary. Here, for the first time, a wearable, highly flexible, and stretchable piezoresistive sensing patch based on carbon nanotubes (CNTs) is reported, which can record muscle expansion or relaxation in real‐time, and thus act as a next‐generation POC sensor. The patch offers an excellent gauge factor for in‐plane stretching and spatial expansion with low hysteresis. The actual extent of muscle expansion is calculated and the gauge factor for applications entailing volumetric deformations is redefined. Additionally, a bluetooth‐low‐energy system that tracks muscle activity in real‐time and transmits the output signals wirelessly to a smartphone app is utilized. Numerical calculations verify that the low stress and strain lead to excellent mechanical reliability and repeatability. Finally, a dummy muscle is inflated using a pneumatic‐based actuator to demonstrate the application of the affixed wearable next‐generation POC sensor.
      A point‐of‐care (POC) wearable strain sensor is developed to monitor the magnitude of swelling/relaxation of the parotid gland, which can help medical practitioners identify viral infections or throat‐related illnesses in earlier stages. The results show that the polymer‐based POC sensing patch can effectively track muscle motion with a high gauge factor and low hysteresis. The output signals of the POC sensing patch are wirelessly monitored on the phone using a Bluetooth‐low‐energy setup and a customized app.
      번역하기

      Point‐of‐care testing (POC) has the ability to detect chronic and infectious diseases early or at the time of occurrence and provide a state‐of‐the‐art personalized healthcare system. Recently, wearable and flexible sensors have been employe...

      Point‐of‐care testing (POC) has the ability to detect chronic and infectious diseases early or at the time of occurrence and provide a state‐of‐the‐art personalized healthcare system. Recently, wearable and flexible sensors have been employed to analyze sweat, glucose, blood, and human skin conditions. However, a flexible sensing system that allows for the real‐time monitoring of throat‐related illnesses, such as salivary parotid gland swelling caused by flu and mumps, is necessary. Here, for the first time, a wearable, highly flexible, and stretchable piezoresistive sensing patch based on carbon nanotubes (CNTs) is reported, which can record muscle expansion or relaxation in real‐time, and thus act as a next‐generation POC sensor. The patch offers an excellent gauge factor for in‐plane stretching and spatial expansion with low hysteresis. The actual extent of muscle expansion is calculated and the gauge factor for applications entailing volumetric deformations is redefined. Additionally, a bluetooth‐low‐energy system that tracks muscle activity in real‐time and transmits the output signals wirelessly to a smartphone app is utilized. Numerical calculations verify that the low stress and strain lead to excellent mechanical reliability and repeatability. Finally, a dummy muscle is inflated using a pneumatic‐based actuator to demonstrate the application of the affixed wearable next‐generation POC sensor.
      A point‐of‐care (POC) wearable strain sensor is developed to monitor the magnitude of swelling/relaxation of the parotid gland, which can help medical practitioners identify viral infections or throat‐related illnesses in earlier stages. The results show that the polymer‐based POC sensing patch can effectively track muscle motion with a high gauge factor and low hysteresis. The output signals of the POC sensing patch are wirelessly monitored on the phone using a Bluetooth‐low‐energy setup and a customized app.