RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재 SCIE SCOPUS

      Reliability of Skeletal Muscle Area Measurement on CT with Different Parameters: A Phantom Study

      한글로보기

      https://www.riss.kr/link?id=A107316223

      • 저자

        Kim Dong Wook (Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Korea.) ;  Ha Jiyeon (Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Korea.) ;  Ko Yousun (Biomedical Research Center, Asan Institute for Life Sciences, Asan Medical Center, Seoul, Korea.) ;  Kim Kyung Won (Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Korea.) ;  Park Taeyong (Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Seoul, Korea.) ;  Lee Jeongjin (School of Computer Science and Engineering, Soongsil University, Seoul, Korea.) ;  You Myung-Won (Department of Radiology, Kyung Hee University Hospital, Seoul, Korea.) ;  Yoon Kwon-Ha (Department of Radiology, Wonkwang University College of Medicine, Wonkwang University Hospital, Iksan, Korea.) ;  Park Ji Yong (Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Korea.) ;  Kee Young Jin (Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Korea.) ;  Kim Hong-Kyu (Health Screening & Promotion Center, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Korea.)

      • 발행기관
      • 학술지명
      • 권호사항
      • 발행연도

        2021

      • 작성언어

        English

      • 주제어
      • 등재정보

        KCI등재,SCIE,SCOPUS

      • 자료형태

        학술저널

      • 수록면

        624-633(10쪽)

      • KCI 피인용횟수

        0

      • DOI식별코드
      • 제공처
      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Objective: To evaluate the reliability of CT measurements of muscle quantity and quality using variable CT parameters. Materials and Methods: A phantom, simulating the L2–4 vertebral levels, was used for this study. CT images were repeatedly acquire...

      Objective: To evaluate the reliability of CT measurements of muscle quantity and quality using variable CT parameters.
      Materials and Methods: A phantom, simulating the L2–4 vertebral levels, was used for this study. CT images were repeatedly acquired with modulation of tube voltage, tube current, slice thickness, and the image reconstruction algorithm. Reference standard muscle compartments were obtained from the reference maps of the phantom. Cross-sectional area based on the Hounsfield unit (HU) thresholds of muscle and its components, and the mean density of the reference standard muscle compartment, were used to measure the muscle quantity and quality using different CT protocols. Signal-to-noise ratios (SNRs) were calculated in the images acquired with different settings.
      Results: The skeletal muscle area (threshold, -29 to 150 HU) was constant, regardless of the protocol, occupying at least 91.7% of the reference standard muscle compartment. Conversely, normal attenuation muscle area (30–150 HU) was not constant in the different protocols, varying between 59.7% and 81.7% of the reference standard muscle compartment. The mean density was lower than the target density stated by the manufacturer (45 HU) in all cases (range, 39.0–44.9 HU). The SNR decreased with low tube voltage, low tube current, and in sections with thin slices, whereas it increased when the iterative reconstruction algorithm was used.
      Conclusion: Measurement of muscle quantity using HU threshold was reliable, regardless of the CT protocol used. Conversely, the measurement of muscle quality using the mean density and narrow HU thresholds were inconsistent and inaccurate across different CT protocols. Therefore, further studies are warranted in future to determine the optimal CT protocols for reliable measurements of muscle quality.

      더보기

      참고문헌 (Reference)

      1 Goodpaster BH, "Subcutaneous abdominal fat and thigh muscle composition predict insulin sensitivity independently of visceral fat" 46 : 1579-1585, 1997

      2 Frontera WR, "Skeletal muscle: a brief review of structure and function" 96 : 183-195, 2015

      3 Goodpaster BH, "Skeletal muscle attenuation determined by computed tomography is associated with skeletal muscle lipid content" 89 : 104-110, 2000

      4 van der Werf A, "Skeletal muscle analyses: agreement between non-contrast and contrast CT scan measurements of skeletal muscle area and mean muscle attenuation" 38 : 366-372, 2018

      5 Cruz-Jentoft AJ, "Sarcopenia: revised European consensus on definition and diagnosis" 48 : 16-31, 2019

      6 Beaudart C, "Sarcopenia in daily practice: assessment and management" 16 : 170-, 2016

      7 Fuchs G, "Quantifying the effect of slice thickness, intravenous contrast and tube current on muscle segmentation: implications for body composition analysis" 28 : 2455-2463, 2018

      8 Prado CM, "Prevalence and clinical implications of sarcopenic obesity in patients with solid tumours of the respiratory and gastrointestinal tracts: a population-based study" 9 : 629-635, 2008

      9 Buckinx F, "Pitfalls in the measurement of muscle mass: a need for a reference standard" 9 : 269-278, 2018

      10 Reinders I, "Muscle quality and myosteatosis: novel associations with mortality risk: the Age, Gene/Environment Susceptibility (AGES)-Reykjavik Study" 183 : 53-60, 2016

      1 Goodpaster BH, "Subcutaneous abdominal fat and thigh muscle composition predict insulin sensitivity independently of visceral fat" 46 : 1579-1585, 1997

      2 Frontera WR, "Skeletal muscle: a brief review of structure and function" 96 : 183-195, 2015

      3 Goodpaster BH, "Skeletal muscle attenuation determined by computed tomography is associated with skeletal muscle lipid content" 89 : 104-110, 2000

      4 van der Werf A, "Skeletal muscle analyses: agreement between non-contrast and contrast CT scan measurements of skeletal muscle area and mean muscle attenuation" 38 : 366-372, 2018

      5 Cruz-Jentoft AJ, "Sarcopenia: revised European consensus on definition and diagnosis" 48 : 16-31, 2019

      6 Beaudart C, "Sarcopenia in daily practice: assessment and management" 16 : 170-, 2016

      7 Fuchs G, "Quantifying the effect of slice thickness, intravenous contrast and tube current on muscle segmentation: implications for body composition analysis" 28 : 2455-2463, 2018

      8 Prado CM, "Prevalence and clinical implications of sarcopenic obesity in patients with solid tumours of the respiratory and gastrointestinal tracts: a population-based study" 9 : 629-635, 2008

      9 Buckinx F, "Pitfalls in the measurement of muscle mass: a need for a reference standard" 9 : 269-278, 2018

      10 Reinders I, "Muscle quality and myosteatosis: novel associations with mortality risk: the Age, Gene/Environment Susceptibility (AGES)-Reykjavik Study" 183 : 53-60, 2016

      11 Hill DL, "Medical image registration" 46 : R1-R45, 2001

      12 Dice LR, "Measures of the amount of ecologic association between species" 26 : 297-302, 1945

      13 Aubrey J, "Measurement of skeletal muscle radiation attenuation and basis of its biological variation" 210 : 489-497, 2014

      14 Tosato M, "Measurement of muscle mass in sarcopenia:from imaging to biochemical markers" 29 : 19-27, 2017

      15 Rogalla P, "Low-dose spiral computed tomography for measuring abdominal fat volume and distribution in a clinical setting" 52 : 597-602, 1998

      16 Prado CM, "Lean tissue imaging: a new era for nutritional assessment and intervention" 38 : 940-953, 2014

      17 Paris MT, "Influence of contrast administration on computed tomography–based analysis of visceral adipose and skeletal muscle tissue in clear cell renal cell carcinoma" 42 : 1148-1155, 2018

      18 Haralick RM, "Image analysis using mathematical morphology" 9 : 532-550, 1987

      19 Lee S, "Exercise without weight loss is an effective strategy for obesity reduction in obese individuals with and without Type 2 diabetes" 99 : 1220-1225, 2005

      20 Duan X, "Electronic noise in CT detectors: impact on image noise and artifacts" 201 : W626-W632, 2013

      21 Goodpaster BH, "Effects of weight loss on regional fat distribution and insulin sensitivity in obesity" 48 : 839-847, 1999

      22 van Vugt JLA, "Contrastenhancement influences skeletal muscle density, but not skeletal muscle mass, measurements on computed tomography" 37 : 1707-1714, 2018

      23 Lang T, "Computed tomographic measurements of thigh muscle cross-sectional area and attenuation coefficient predict hip fracture: the health, aging, and body composition study" 25 : 513-519, 2010

      24 Singh S, "Comparison of hybrid and pure iterative reconstruction techniques with conventional filtered back projection: dose reduction potential in the abdomen" 36 : 347-353, 2012

      25 Martin L, "Cancer cachexia in the age of obesity:skeletal muscle depletion is a powerful prognostic factor, independent of body mass index" 31 : 1539-1547, 2013

      26 Amini B, "Approaches to assessment of muscle mass and myosteatosis on computed tomography: a systematic review" 74 : 1671-1678, 2019

      27 Weickert J, "Anisotropic diffusion in image processing" Teubner 1998

      28 Singh S, "Adaptive statistical iterative reconstruction technique for radiation dose reduction in chest CT: a pilot study" 259 : 565-573, 2011

      29 Singh S, "Abdominal CT: comparison of adaptive statistical iterative and filtered back projection reconstruction techniques" 257 : 373-383, 2010

      30 Nakayama Y, "Abdominal CT with low tube voltage: preliminary observations about radiation dose, contrast enhancement, image quality, and noise" 237 : 945-951, 2005

      31 Otsu N, "A threshold selection method from gray-level histograms" 9 : 62-66, 1979

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2016-11-15 학회명변경 영문명 : The Korean Radiological Society -> The Korean Society of Radiology KCI등재
      2010-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2007-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2006-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2003-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 1.61 0.46 1.15
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.93 0.84 0.494 0.06
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼