RISS 학술연구정보서비스

검색

인기 검색어

    다국어 입력

    http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

    변환된 중국어를 복사하여 사용하시면 됩니다.

    예시)
    • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
    • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
    닫기
    KCI등재 SCI SCIE SCOPUS

    Evaluation of MR-based PET Images with a Homogeneous map by Using Integrated PET/MR

    한글로보기

    https://www.riss.kr/link?id=A105894360

    • 0

      상세조회
    • 0

      다운로드
    서지정보 열기
    • 내보내기
    • 내책장담기
    • 공유하기
    • 오류접수
    인용문이 복사되었습니다.

    부가정보

    다국어 초록 (Multilingual Abstract) kakao i 다국어 번역

    This study intends to obtain magnetic resonance (MR)-based positron emission tomography (PET) images with a relatively uniform map by using a National Electrical Manufacturers Asso- ciation (NEMA) International Electrotechnical Commission (IEC) body phantom and to evaluate the PET phantom images by applying various reconstruction parameters in accordance with the protocol of the NEMA. In order to obtain a uniform MR-based map, we set the initial voltage of the RF transmitter adjustment algorithm to 75 V, and we obtained the attenuation-corrected PET image by applying the two-point vibe Dixon MR sequence. The images reconstructed using the 3D ordered subset expectation maximization (OSEM) algorithm with the point spread function (PSF) showed the highest percentage of contrast recovery and the lowest percentage background variabil- ity compared to the other 3D reconstruction algorithms like the Filtered backprojection (FBP), 3D OSEM, and 3D OSEM with PSF algorithms. The 3D OSEM with PSF reconstruction algorithm is confirmed to be effective for maintaining the optimum image quality.
    번역하기

    This study intends to obtain magnetic resonance (MR)-based positron emission tomography (PET) images with a relatively uniform map by using a National Electrical Manufacturers Asso- ciation (NEMA) International Electrotechnical Commission (IEC) body p...

    This study intends to obtain magnetic resonance (MR)-based positron emission tomography (PET) images with a relatively uniform map by using a National Electrical Manufacturers Asso- ciation (NEMA) International Electrotechnical Commission (IEC) body phantom and to evaluate the PET phantom images by applying various reconstruction parameters in accordance with the protocol of the NEMA. In order to obtain a uniform MR-based map, we set the initial voltage of the RF transmitter adjustment algorithm to 75 V, and we obtained the attenuation-corrected PET image by applying the two-point vibe Dixon MR sequence. The images reconstructed using the 3D ordered subset expectation maximization (OSEM) algorithm with the point spread function (PSF) showed the highest percentage of contrast recovery and the lowest percentage background variabil- ity compared to the other 3D reconstruction algorithms like the Filtered backprojection (FBP), 3D OSEM, and 3D OSEM with PSF algorithms. The 3D OSEM with PSF reconstruction algorithm is confirmed to be effective for maintaining the optimum image quality.

    더보기

    참고문헌 (Reference)

    1 D. W. Townsend, 53 : 1-, 2008

    2 G Delso, 55 : 4361-, 2010

    3 H. Zaid, 34 : 1525-, 2007

    4 G. Delso, 36 : 86-, 2009

    5 C. S. Levin, 35 : 1907-, 2016

    6 S. P. Butler, 29 : 593-, 1988

    7 L. R. MacDonald, 38 : 2948-, 2011

    8 P. S. Tofts, 104 : 143-, 1994

    9 M. A. Bernstein, 24 : 735-, 2006

    10 Z. Susanne, 54 : 1464-, 2013

    1 D. W. Townsend, 53 : 1-, 2008

    2 G Delso, 55 : 4361-, 2010

    3 H. Zaid, 34 : 1525-, 2007

    4 G. Delso, 36 : 86-, 2009

    5 C. S. Levin, 35 : 1907-, 2016

    6 S. P. Butler, 29 : 593-, 1988

    7 L. R. MacDonald, 38 : 2948-, 2011

    8 P. S. Tofts, 104 : 143-, 1994

    9 M. A. Bernstein, 24 : 735-, 2006

    10 Z. Susanne, 54 : 1464-, 2013

    11 A. Simmons, 32 : 121-, 1994

    12 T. S. Ibrahim, 19 : 219-, 2001

    13 J. H. Kim, 53 : 1878-, 2012

    14 C. M. Collins, 21 : 192-, 2005

    15 A. M. Karlberg, 3 : 5-, 2016

    16 B. J. Pichler, 47 : 639-, 2006

    17 M. A. Martinez, 50 : 520-, 2009

    18 B. Aklan, 57 : 78-, 2016

    19 정진호, "PET/MRI: Technical Challenges and Recent Advances" 대한핵의학회 50 (50): 3-12, 2016

    20 National Electrical Manufacturers Association, "NEMA Standards Publication NU 2-2007, Performance measurements of positron emission tomographs, 26"

    더보기

    동일학술지(권/호) 다른 논문

    동일학술지 더보기

    더보기

    분석정보

    View

    상세정보조회

    0

    Usage

    원문다운로드

    0

    대출신청

    0

    복사신청

    0

    EDDS신청

    0

    동일 주제 내 활용도 TOP

    더보기

    주제

    연도별 연구동향

    연도별 활용동향

    연관논문

    연구자 네트워크맵

    공동연구자 (7)

    유사연구자 (20) 활용도상위20명

    인용정보 인용지수 설명보기

    학술지 이력

    학술지 이력
    연월일 이력구분 이력상세 등재구분
    2023 평가 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
    2020-01-01 등재 등재학술지 유지 (해외등재 학술지 평가) KCI등재
    2011-01-01 등재 등재학술지 유지 (등재유지) KCI등재
    2009-01-01 등재 등재학술지 유지 (등재유지) KCI등재
    2007-01-01 등재 SCI 등재 (등재유지) KCI등재
    2005-01-01 등재 등재학술지 유지 (등재유지) KCI등재
    2002-07-01 등재 등재학술지 선정 (등재후보2차) KCI등재
    2000-01-01 등재 등재후보학술지 선정 (신규평가) KCI등재후보
    더보기

    학술지 인용정보

    학술지 인용정보
    기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
    2016 0.47 0.15 0.31
    KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
    0.26 0.2 0.26 0.03
    더보기

    연관 공개강의(KOCW)

    이 자료와 함께 이용한 RISS 자료

    나만을 위한 추천자료

    해외이동버튼