      Variable density magnetization transfer (vdMT) imaging for 7T MR imaging

      한글로보기

      https://www.riss.kr/link?id=A107507429

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      <P><B>Abstract</B></P> <P>As the use of ultra-high field (UHF; ≥7T) magnetic resonance (MR) imaging expands, there is an increasing need to establish high-resolution MR imaging protocols for patients with neurological...

      <P><B>Abstract</B></P> <P>As the use of ultra-high field (UHF; ≥7T) magnetic resonance (MR) imaging expands, there is an increasing need to establish high-resolution MR imaging protocols for patients with neurological disease. Magnetization transfer (MT) imaging has been used to provide information about changes in the magnitude of the restricted protons that are caused by tissue damages. Several studies have found that MTR has a good sensitivity to measure changes in myelin concentration within the brain. Because of the much higher specific absorption rate (SAR) of tissue and longer acquisition time required for UHF, however, <I>in-vivo</I> studies using conventional pulsed MT sequences at UHF have not been well utilized.</P> <P>In this study, we introduce a new MT data acquisition approach using a 7T MR system, variable density magnetization transfer (vdMT) imaging, which can be reasonably included in a routine patient scan protocol with a much shorter scan time and reduced discomfort to the patient.</P> <P>To reduce SAR and scan time while maintaining at least similar MTR image quality to that obtained with the conventional method, a higher density of MT RF pulses was applied in the center of k-space, and sparsely applied MT RF pulses were used in the outer part of k-space. The fraction of k-space receiving 100% MT RF density and TR were optimized based on <I>in-vivo</I> ROI analysis, and results were confirmed with high-resolution MTR map using a vdMT approach from healthy controls and patients with multiple sclerosis (MS).</P> <P>The experimental results confirmed that vdMT imaging can cover a whole brain volume in an acceptable scan time for routine patient scans while providing MTR image quality at least similar to that obtained with conventional MT imaging (correlation coefficient=0.95 in an agar-gel phantom [MT offset frequency=1kH], 0.90 in a postmortem MS brain, and 0.85 in the 4 healthy volunteers). MS lesions were associated with signal reductions in the postmortem MS brains and in the patients with MS.</P> <P>In this study, we have described a new approach for acquiring high-resolution MTR map of the whole brain volume using 7T MR imaging. This vdMT method provides similar image quality to that obtained with the conventional method, and shortens the scan time by reducing SAR. These results suggest that vdMT approach is a method that could be used for UHF scans of patients with neurological disease.</P> <P><B>Highlights</B></P> <P> <UL> <LI> vdMT shortens the scan time by reducing SAR. </LI> <LI> vdMT method provides image quality at least similar to that obtained with conventional method. </LI> <LI> vdMT generates high resolution MT data in clinically reasonable scan time (<6 min). </LI> <LI> vdMT method is appealing for clinical neuroimaging applications in UHF. </LI> </UL> </P> <P><B>Graphical abstract</B></P> <P>[DISPLAY OMISSION]</P>

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼