      Purpose : This study measured obiectively the accommodative responses stimulated by push-up method and minus lens method with the NVision-K 5001 open-field autorefractor, and compared the results with previously published data. Methods : Forty-five su...

      Purpose : This study measured obiectively the accommodative responses stimulated by push-up method and minus lens method with the NVision-K 5001 open-field autorefractor, and compared the results with previously published data. Methods : Forty-five subiects aged 19 to 29 years (mean 22. 7±2.4 years) participated in this study. Three conditions were used to stimulate accommodation and accommodative responses were measured objectively by NVision-K 5001 : (1) push-up test under binocular viewing condition ; the target was placed at vergence ranging from 0-50 in 1D steps. (2) push-up test under monocular viewing condition ; the target was placed at vergence ranging from 1-50 in 1D steps. (3) minus lens test under monocular viewing condition ; a distant(6 m) target viewed through increasing powered minus lenses from 1-50 in 10 steps. Trial lens calibration procedures were also performed to assess the accuracy of the NVision-K 5001. Results : The calib1·ation of NVision-1< 5001 wilh trial lenses showed linear regression equation which was close to the idea! 1 : 1 line(y = -1.005x + 0.060, r2 = 0.999. p < 0.001). The accommodative responses measured with the NVision-K 5001 for the push-up and minus lens- stimulated accommodation progressively lagged behind the increasing acconunodative stimulus. 8oth push-up methods under monocular and binocular viewing conditions showed significanlly higher acconunodative responses than minus lens method(p < 0.001). Push-up method under binocular viewing condition demonstrated slightly higher accommodative responses compared with monocular condition, but the difference was not significant(p = 0.958). Conclusion : The objective accommodative responses stimulated by push-up and minus lens method and measured with open-field autorefractor showed good agreement with previously published data.

      더보기

      참고문헌 (Reference)

      1 신진아, "안기능과 임상굴절" 한미의학 113-, 2003

      2 McClelland JF, "The repeatability and validity of dynamic retinoscopy in assessing the accommodative responses" 23 : 243-250, 2003

      3 Dirk S, "The effect of monocular and binocular viewing on the accommodation response to real targets in emmetropia and myopia" 82 (82): 279-285, 2005

      4 Wold JE, "Subjective and objective measuremen of human accommodative amplitude" 29 (29): 1878-1888, 2003

      5 Stark LA, "Subject instructions and methods of target presentation in accommodation research" 35 (35): 528-537, 1994

      6 Win-Hall DM, "Objective accommodation measurement with the Grand Seiko and Hartinger Coincidence Refractometer" 84 (84): 879-887, 2007

      7 Anderson HA, "Minuslens- stimulated accommodative amplitude decreases sigmoidally with age : A study of objectively measured accommodative amplitudes from age 3" 49 (49): 2919-2926, 2008

      8 Rosenfield M, "Effect of target proximity on the open-loop accommodative response" 67 (67): 74-79, 1990

      9 Millodot M, "Dictionary of optometry and visual science, 6th ed" Butterworth-Heinemann 3-, 2004

      10 Wick B, "Convergence accommodation: laboratory and clinical evaluation" 68 (68): 226-231, 1991

      1 신진아, "안기능과 임상굴절" 한미의학 113-, 2003

      2 McClelland JF, "The repeatability and validity of dynamic retinoscopy in assessing the accommodative responses" 23 : 243-250, 2003

      3 Dirk S, "The effect of monocular and binocular viewing on the accommodation response to real targets in emmetropia and myopia" 82 (82): 279-285, 2005

      4 Wold JE, "Subjective and objective measuremen of human accommodative amplitude" 29 (29): 1878-1888, 2003

      5 Stark LA, "Subject instructions and methods of target presentation in accommodation research" 35 (35): 528-537, 1994

      6 Win-Hall DM, "Objective accommodation measurement with the Grand Seiko and Hartinger Coincidence Refractometer" 84 (84): 879-887, 2007

      7 Anderson HA, "Minuslens- stimulated accommodative amplitude decreases sigmoidally with age : A study of objectively measured accommodative amplitudes from age 3" 49 (49): 2919-2926, 2008

      8 Rosenfield M, "Effect of target proximity on the open-loop accommodative response" 67 (67): 74-79, 1990

      9 Millodot M, "Dictionary of optometry and visual science, 6th ed" Butterworth-Heinemann 3-, 2004

      10 Wick B, "Convergence accommodation: laboratory and clinical evaluation" 68 (68): 226-231, 1991

      11 Rosenfield M, "Comparison of clinical techniques to assess the near accommodative response" 73 (73): 382-388, 1996

      12 Davies LN, "Clinical evaluation of the Shin-Nippon NVision-K 5001 /Grand Seiko WR-5100K Autorefractor" 80 (80): 320-324, 2003

      13 Ciuffreda KJ, "Accommodation, the pupil,and presbyopia. In BenjaminWJ(ed). Clinical Refraction" W.B. Saunders 77-120, 1998

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2026 평가예정 재인증평가 신청대상 (재인증)
      2020-01-01 평가 등재학술지 유지 (재인증) KCI등재
      2017-01-01 평가 등재학술지 유지 (계속평가) KCI등재
      2013-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2012-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2010-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.74 0.74 0.71
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.62 0.59 0.899 0.1
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼