RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      SCOPUS SCIE

      Investigation of the Performance of Scintillator-Based CMOS Flat Panel Detectors for X-Ray and Thermal Neutron Imaging

      한글로보기

      https://www.riss.kr/link?id=A107724309

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      <P>Recent advances in of silicon-based CMOS (complementary metal-oxide-semiconductor) flat panel detectors have resulted in an attractive use of cost-effective radiation imaging devices for X-ray and neutron radiography/tomography system. Indire...

      <P>Recent advances in of silicon-based CMOS (complementary metal-oxide-semiconductor) flat panel detectors have resulted in an attractive use of cost-effective radiation imaging devices for X-ray and neutron radiography/tomography system. Indirect detection methods consisted of an X-ray converter (or a scintillator screen) and photodiode arrays are more widely used in high resolution micro-CT (computed tomography), dental and industrial NDT applications. In this study, The terbium-doped gadolinium oxysulfide (Gd<SUB>2</SUB>O<SUB>2</SUB> S:Tb, Gadox) scintillator screens with different thickness (several 30-140 m thickness) were directly coupled with a fiber-optic plate (FOP) of a commercially available CMOS imaging device for high resolution X-ray and thermal neutron radiography. The RadEye1 CMOS APS (active pixel sensor) imager having a large active area of 25 × 50 mm<SUP>2</SUP> and 48 m pixel pitch was selected for X-ray and thermal neutron imaging with high resolution. The scintillation properties and imaging performance such as relative light output, linearity and spatial resolution were measured and evaluated under X-ray and thermal neutron beam exposure. The good linearity and high spatial resolution characteristics in X-ray and thermal neutron imaging experiments were achieved by using compact, cost-effective imaging detector with exchangeable Gadox scintillator screens.</P>

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼