1 유영준, "중공형 GFRP 보강근의 인장성능 실험연구" 한국구조물진단유지관리공학회 19 (19): 45-52, 2015
2 오홍섭, "기계식 앵커시스템을 활용한 FRP 보강근의 장기성능에 대한 실험적 평가" 한국방재학회 15 (15): 147-154, 2015
3 김민철, "고온손상된 GFRP 보강근의 장기 잔존 계면전단강도 예측" 한국구조물진단유지관리공학회 18 (18): 108-115, 2014
4 Canadian Standards Association (CSA), "Specification for fibre-reinforced polymers. CAN/CSA-S807"
5 Stephen V. Grelle, "Review of Anchorage Systems for Externally-Bonded FRP Laminates" 한국콘크리트학회 7 (7): 17-33, 2013
6 Schmidt, J. W., "Mechanical anchorage of FRP tendons–a literature review" 32 : 110-121, 2012
7 American Concrete Institute, "Guide test methods for fiber-reinforced polymer, ACI 440.3R-12"
8 American Concrete Institute, "Guide for the design and construction of concrete reinforced with FRP bars, ACI 440.1R-15"
9 American Concrete Institute, "Guide for the Design and Construction of Concrete Reinforced with FRP Bars, ACI 440.1R-03"
10 Dai, L., "Experimental Study on Tensile Properties of GFRP Bars Embedded in Concrete Beams with Working Cracks" EDP Sciences 88 : 02005-, 2017
1 유영준, "중공형 GFRP 보강근의 인장성능 실험연구" 한국구조물진단유지관리공학회 19 (19): 45-52, 2015
2 오홍섭, "기계식 앵커시스템을 활용한 FRP 보강근의 장기성능에 대한 실험적 평가" 한국방재학회 15 (15): 147-154, 2015
3 김민철, "고온손상된 GFRP 보강근의 장기 잔존 계면전단강도 예측" 한국구조물진단유지관리공학회 18 (18): 108-115, 2014
4 Canadian Standards Association (CSA), "Specification for fibre-reinforced polymers. CAN/CSA-S807"
5 Stephen V. Grelle, "Review of Anchorage Systems for Externally-Bonded FRP Laminates" 한국콘크리트학회 7 (7): 17-33, 2013
6 Schmidt, J. W., "Mechanical anchorage of FRP tendons–a literature review" 32 : 110-121, 2012
7 American Concrete Institute, "Guide test methods for fiber-reinforced polymer, ACI 440.3R-12"
8 American Concrete Institute, "Guide for the design and construction of concrete reinforced with FRP bars, ACI 440.1R-15"
9 American Concrete Institute, "Guide for the Design and Construction of Concrete Reinforced with FRP Bars, ACI 440.1R-03"
10 Dai, L., "Experimental Study on Tensile Properties of GFRP Bars Embedded in Concrete Beams with Working Cracks" EDP Sciences 88 : 02005-, 2017
11 Lu, Z., "Effects of exposure to elevated temperatures and subsequent immersion in water or alkaline solution on the mechanical properties of pultruded BFRP plates" 77 : 421-430, 2015
12 Benmokrane, B., "Durability performance and service life of CFCC tendons exposed to elevated temperature and alkaline environment" 20 (20): 04015043-, 2015
13 Ali, A. H., "Durability performance and long-term prediction models of sand-coated basalt FRP bars" 157 : 248-258.5, 2019
14 Benmokrane, B., "Durability of glass fiber-reinforced polymer reinforcing bars in concrete environment" 6 (6): 143-153, 2002
15 Robert, M., "Durability of GFRP reinforcing bars embedded in moist concrete" 13 (13): 66-73, 2009
16 Wang, J., "Durability and prediction models of fiber-reinforced polymer composites under various environmental conditions : A critical review" 35 (35): 179-211, 2016
17 Canadian Standards Association(CSA), "Design and construction of building structures with fibre-reinforced polymers. CAN/CSA S806-12"
18 Wu, G., "Degradation of basalt FRP bars in alkaline environment" 22 (22): 649-657, 2015
19 Benmokrane, B., "Comparison between ASTM D7205 and CSA S806Tensile-Testing Methods for Glass Fiber–Reinforced Polymer Bars" 21 (21): 04017038-, 2017
20 Benmokrane, B., "Characterization and comparative durability study of glass/vinylester, basalt/vinylester, and basalt/epoxy FRP bars" 19 (19): 04015008-, 2015
21 Chen, Y., "Accelerated aging tests for evaluations of durability performance of FRP reinforcing bars for concrete structures" 78 (78): 101-111, 2007
22 "ASTM Standard D7792M. Standard Practice for Freeze/Thaw Conditioning of Pultruded Fiber Reinforced Polymer (FRP) Composites Used in Structural Designs. ASTM D7792M"
23 "ASTM Standard D7205 / D7205M-06. Standard test method for tensile properties of fiber reinforced polymer matrix composite bars. ASTM D7205 / D7205M-06"