RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      SCOPUS SCIE

      Radiometric Characteristics of KOMPSAT-3 Multispectral Images Using the Spectra of Well-Known Surface Tarps

      한글로보기

      https://www.riss.kr/link?id=A107499576

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      <P>A vicarious calibration with reference to characterized surface tarps was conducted to determine the first radiometric characteristics of KOMPSAT-3. The 6S radiative transfer model was also used by inputting various initial parameters, such as the spectral response function of KOMPSAT-3, and atmospheric and geometric conditions. Moderate-Resolution Imaging Spectroradiometer atmospheric products, such as aerosol optical depth, precipitable water, and total ozone, were used as input parameters to interpret solar radiation reflection, scattering, and absorption effects. In the first field campaign, the radiometric coefficients from each of the spectral bands were estimated by calculating the predicted radiance at sensor level and the digital number (DN) of KOMPSAT-3 based on a linear least squares fit over a range of target reflectance levels. The second field campaign measurements were also used to upgrade the KOMPSAT-3 DNs to radiance coefficients. The root-mean-square error differences between simulated radiance and measured radiance during the second field campaign for 'sensor-to-itself' calibration were 2.072 W/m(2)sr (blue), 6.80 W/m(2)sr (green), 7.512 W/m(2)sr (NIR), and 5.712 W/m(2)sr (red), respectively. This highlights that radiometric calibration with tarps is a reliable method. Furthermore, the gain ratio between the first and the second one was <5%, indicating reasonable radiometric calibration results. Additionally, cross-validation of KOMPSAT-3 with radiometrically well-calibrated Landsat-8 was performed over bright desert. Although the difference between the vicarious calibration with surface tarps and cross-validation with Landsat-8 was significant, reasonable results were obtained under close geometrical conditions, despite inherent vicarious calibration error.</P>
      번역하기

      <P>A vicarious calibration with reference to characterized surface tarps was conducted to determine the first radiometric characteristics of KOMPSAT-3. The 6S radiative transfer model was also used by inputting various initial parameters, such a...

      <P>A vicarious calibration with reference to characterized surface tarps was conducted to determine the first radiometric characteristics of KOMPSAT-3. The 6S radiative transfer model was also used by inputting various initial parameters, such as the spectral response function of KOMPSAT-3, and atmospheric and geometric conditions. Moderate-Resolution Imaging Spectroradiometer atmospheric products, such as aerosol optical depth, precipitable water, and total ozone, were used as input parameters to interpret solar radiation reflection, scattering, and absorption effects. In the first field campaign, the radiometric coefficients from each of the spectral bands were estimated by calculating the predicted radiance at sensor level and the digital number (DN) of KOMPSAT-3 based on a linear least squares fit over a range of target reflectance levels. The second field campaign measurements were also used to upgrade the KOMPSAT-3 DNs to radiance coefficients. The root-mean-square error differences between simulated radiance and measured radiance during the second field campaign for 'sensor-to-itself' calibration were 2.072 W/m(2)sr (blue), 6.80 W/m(2)sr (green), 7.512 W/m(2)sr (NIR), and 5.712 W/m(2)sr (red), respectively. This highlights that radiometric calibration with tarps is a reliable method. Furthermore, the gain ratio between the first and the second one was <5%, indicating reasonable radiometric calibration results. Additionally, cross-validation of KOMPSAT-3 with radiometrically well-calibrated Landsat-8 was performed over bright desert. Although the difference between the vicarious calibration with surface tarps and cross-validation with Landsat-8 was significant, reasonable results were obtained under close geometrical conditions, despite inherent vicarious calibration error.</P>

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼