RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재 SCOPUS

      Accuracy and reliability of stitched cone-beam computed tomography images

      한글로보기

      https://www.riss.kr/link?id=A104768843

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Purpose: This study was performed to evaluate the linear distance accuracy and reliability of stitched small field of view (FOV) cone-beam computed tomography (CBCT) reconstructed images for the fabrication of implant surgical guides. Material and Me...

      Purpose: This study was performed to evaluate the linear distance accuracy and reliability of stitched small field of view (FOV) cone-beam computed tomography (CBCT) reconstructed images for the fabrication of implant surgical guides.
      Material and Methods: Three gutta percha points were fixed on the inferior border of a cadaveric mandible to serve as control reference points. Ten additional gutta percha points, representing fiduciary markers, were scattered on the buccal and lingual cortices at the level of the proposed complete denture flange. A digital caliper was used to measure the distance between the reference points and fiduciary markers, which represented the anatomic linear dimension. The mandible was scanned using small FOV CBCT, and the images were then reconstructed and stitched using the manufacturer’s imaging software. The same measurements were then taken with the CBCT software.
      Results: The anatomic linear dimension measurements and stitched small FOV CBCT measurements were statistically evaluated for linear accuracy. The mean difference between the anatomic linear dimension measurements and the stitched small FOV CBCT measurements was found to be 0.34 mm with a 95% confidence interval of +0.24 - +0.44 mm and a mean standard deviation of 0.30 mm. The difference between the control and the stitched small FOV CBCT measurements was insignificant within the parameters defined by this study.
      Conclusion: The proven accuracy of stitched small FOV CBCT data sets may allow image-guided fabrication of implant surgical stents from such data sets.

      더보기

      참고문헌 (Reference)

      1 Greenstein G, "The mental foramen and nerve : clinical and anatomical factors related to dental implant placement : a literature review" 77 : 1933-1943, 2006

      2 Balshi TJ, "Teeth in a day for the maxilla and mandible : case report" 5 : 11-16, 2003

      3 Balshi SF, "Surgical planning and prosthesis construction using computer technology and medical imaging for immediate loading of implants in the pterygomaxillary region" 26 : 239-247, 2006

      4 Guerrero ME, "State-of-the-art on cone beam CT imaging for preoperative planning of implant placement" 10 : 1-7, 2006

      5 Lindh C, "Measurements of distances related to the mandibular canal in radiographs" 6 : 96-103, 1995

      6 Scarfe WC, "Maxillofacial cone beam computed tomography: essence, elements and steps to interpretation" 57 : 46-60, 2012

      7 Periago DR, "Linear accuracy and reliability of cone beam CT derived 3-dimensional images constructed using an orthodontic volumetric rendering program" 78 : 387-395, 2008

      8 Parel SM, "Interactive imaging for implant planning, placement, and prosthesis construction" 62 : 41-47, 2004

      9 Kraut RA., "Interactive CT diagnostics, planning and preparation for dental implants" 7 : 19-25, 1998

      10 Sanna A, "Immediately loaded CAD-CAM manufactured fixed complete dentures using flapless implant placement procedures : a cohort study of consecutive patients" 97 : 331-339, 2007

      1 Greenstein G, "The mental foramen and nerve : clinical and anatomical factors related to dental implant placement : a literature review" 77 : 1933-1943, 2006

      2 Balshi TJ, "Teeth in a day for the maxilla and mandible : case report" 5 : 11-16, 2003

      3 Balshi SF, "Surgical planning and prosthesis construction using computer technology and medical imaging for immediate loading of implants in the pterygomaxillary region" 26 : 239-247, 2006

      4 Guerrero ME, "State-of-the-art on cone beam CT imaging for preoperative planning of implant placement" 10 : 1-7, 2006

      5 Lindh C, "Measurements of distances related to the mandibular canal in radiographs" 6 : 96-103, 1995

      6 Scarfe WC, "Maxillofacial cone beam computed tomography: essence, elements and steps to interpretation" 57 : 46-60, 2012

      7 Periago DR, "Linear accuracy and reliability of cone beam CT derived 3-dimensional images constructed using an orthodontic volumetric rendering program" 78 : 387-395, 2008

      8 Parel SM, "Interactive imaging for implant planning, placement, and prosthesis construction" 62 : 41-47, 2004

      9 Kraut RA., "Interactive CT diagnostics, planning and preparation for dental implants" 7 : 19-25, 1998

      10 Sanna A, "Immediately loaded CAD-CAM manufactured fixed complete dentures using flapless implant placement procedures : a cohort study of consecutive patients" 97 : 331-339, 2007

      11 BouSerhal C, "Imaging technique selection for the preoperative planning of oral implants : a review of the literature" 4 : 156-172, 2002

      12 Mayo JR., "High resolution computed tomography. Technical aspects" 29 : 1043-1049, 1991

      13 Kopp S, "Dimensional stability in composite cone beam computed tomography" 39 : 512-516, 2010

      14 Ganz SD., "Computer-aided design/computer-aided manufacturing applications using CT and cone beam CT scanning technology" 52 : 777-808, 2008

      15 Jung RE, "Computer technology applications in surgical implant dentistry : a systematic review" 24 : 92-109, 2009

      16 Hultin M, "Clinical advantages of computer-guided implant placement : a systematic review" 23 : 124-135, 2012

      17 Lee S, "Bone density assessments of dental implant sites: 3. Bone quality evaluation during osteotomy and implant placement" 22 : 208-212, 2007

      18 Aranyarachkul P, "Bone density assessments of dental implant sites: 2. Quantitative cone-beam computerized tomography" 20 : 416-424, 2005

      19 Lascala CA, "Analysis of the accuracy of linear measurements obtained by cone beam computed tomography (CBCT-NewTom)" 33 : 291-294, 2004

      20 Hassan B, "Accuracy of three-dimensional measurements obtained from cone beam computed tomography surface-rendered images for cephalometric analysis:influence of patient scanning position" 31 : 129-134, 2009

      21 Sarment DP, "Accuracy of implant placement with a stereolithographic surgical guide" 18 : 571-577, 2003

      22 Valente F, "Accuracy of computer-aided oral implant surgery : a clinical and radiographic study" 24 : 234-242, 2009

      23 Kobayashi K, "Accuracy in measurement of distance using limited cone-beam computerized tomography" 19 : 228-231, 2004

      24 Berco M, "Accuracy and reliability of linear cephalometric measurements from cone-beam computed tomography scans of a dry human skull" 136 : 17.e1-17.e9, 2009

      25 Nikzad S, "A novel stereolithographic surgical guide template for planning treatment involving a mandibular dental implant" 66 : 1446-1454, 2008

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2019-03-27 학회명변경 한글명 : 대한구강악안면방사선학회 -> 대한영상치의학회 KCI등재
      2012-04-16 학술지명변경 한글명 : 대한구강악안면방사선학회지 -> Imaging Science in Dentistry KCI등재
      2011-03-29 학술지명변경 외국어명 : Korean Journal of Oral and Maxillofacial Radiology -> Imaging Science in Dentistry KCI등재
      2010-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2008-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2006-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2003-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2002-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2000-07-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.12 0.12 0.11
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.11 0.12 0.217 0.02
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼