RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재

      소프트 콘택트렌즈의 새그깊이 측정에 관한 연구 = A Study on Sagittal Depth Measurement of Soft Contact Lenses

      한글로보기

      https://www.riss.kr/link?id=A108296054

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Purpose : To compare the difference in sagittal depth between soft contact lenses of 15 products from 4 manufacturers sold in Korea and to find out whether the lenses are relatively steep or flat. Methods : The sagittal depth of soft contact lenses wa...

      Purpose : To compare the difference in sagittal depth between soft contact lenses of 15 products from 4 manufacturers sold in Korea and to find out whether the lenses are relatively steep or flat.
      Methods : The sagittal depth of soft contact lenses was measured through photography using a rectangular petri dish made of polystyrene containing saline and a reference body with a reference line. The contact lenses used were 15 commercially available soft contact lenses with -3.00 D.
      Results : The measured sagittal depth was 3.68±0.16 mm, showing a range of 3.42 to 3.96 mm. The calculated sagittal depth was 3.67±0.15mm, and there was a relatively large difference in some lenses. The calculated base curve for each measured sagittal depth was 8.58±0.16 mm, and the base curve suggested by the manufacturer was 8.59+0.12 mm. There was a relatively large difference in some lenses.
      Conclusion : The difference in sagittal depth of 15 soft contact lens products sold in Korea could be compared, and additional information on whether the lenses were relatively steep or flat could be obtained through the measured sagittal depth and the calculated base curve.

      더보기

      국문 초록 (Abstract)

      목적 : 국내에서 판매되는 4개 제조사의 15개 제품들의 소프트 콘택트렌즈 간의 새그깊이 차이를 비교해보고 렌즈들 이 상대적으로 가파른지 혹은 편평한지에 대해 알아보고자 하였다. 방...

      목적 : 국내에서 판매되는 4개 제조사의 15개 제품들의 소프트 콘택트렌즈 간의 새그깊이 차이를 비교해보고 렌즈들 이 상대적으로 가파른지 혹은 편평한지에 대해 알아보고자 하였다.
      방법 : 식염수가 포함된 폴리스티렌 재질의 사각페트리디쉬와 기준선이 있는 기준체를 사용하여 소프트 콘택트 렌즈의 새그깊이를 사진 촬영을 통해서 측정하였다. 사용된 콘택트렌즈는 시중에서 판매되는 -3.00 D인 15개 제 품의 소프트 콘택트렌즈이었다.
      결과 : 측정된 렌즈의 새그깊이는 3.68±0.16 mm로 3.42~3.96 mm의 범위를 보여 주었다. 계산된 렌즈의 새그깊이는 3.67±0.15 mm이었고, 일부 렌즈에서 상대적으로 큰 차이가 있었다. 측정된 새그깊이 별 계산된 기 본커브는 8.58±0.16 mm이었고, 제조 회사의 제시된 기본커브는 8.59+0.12 mm 이었다. 일부 렌즈에서 상대적 으로 큰 차이가 있었다.
      결론 : 국내에서 판매되는 15개의 소프트 콘택트렌즈 제품들의 새그깊이 차이를 비교할 수 있었고, 측정된 새 그깊이와 그에 따른 계산된 기본커브를 통해 렌즈들이 상대적으로 가파른지 혹은 편평한지에 대한 추가적인 정보 를 얻을 수 있었다.

      더보기

      참고문헌 (Reference) 논문관계도

      1 Eef van der Worp, "When was the last time you fitted a soft lens?" Elsevier BV 43 (43): 415-417, 2020

      2 Hall L, "What you need to know about sagittal height and scleral lenses"

      3 Eef van der Worp, "Variation in sag values in daily disposable, reusable and toric soft contact lenses" Elsevier BV 44 (44): 101386-, 2021

      4 Lee A. Hall, "The Influence of Corneoscleral Topography on Soft Contact Lens Fit" Association for Research in Vision and Ophthalmology (ARVO) 52 (52): 6801-6806, 2011

      5 Eef van der Worp, "Sagittal height differences of frequent replacement silicone hydrogel contact lenses" Elsevier BV 38 (38): 157-162, 2015

      6 Stefano Giovanzana, "Sagittal height differences of disposable soft contact lenses" Springer Science and Business Media LLC 40 (40): 459-465, 2019

      7 LEON F. GARNER, "Sagittal Height of the Anterior Eye and Contact Lens Fitting" Ovid Technologies (Wolters Kluwer Health) 59 (59): 301-305, 1982

      8 MALCOLM M. BIBBY, "Sagittal Depth Considerations in the Selection of the Base Curve Radius of a Soft Contact Lens" Ovid Technologies (Wolters Kluwer Health) 56 (56): 407-413, 1979

      9 Gundal R, "Peripheral keratometry and soft contact lens fitting" 2 (2): 611-613, 1986

      10 Graeme Young, "Ocular sagittal height and soft contact lens fit" Elsevier BV 15 (15): 45-49, 1992

      1 Eef van der Worp, "When was the last time you fitted a soft lens?" Elsevier BV 43 (43): 415-417, 2020

      2 Hall L, "What you need to know about sagittal height and scleral lenses"

      3 Eef van der Worp, "Variation in sag values in daily disposable, reusable and toric soft contact lenses" Elsevier BV 44 (44): 101386-, 2021

      4 Lee A. Hall, "The Influence of Corneoscleral Topography on Soft Contact Lens Fit" Association for Research in Vision and Ophthalmology (ARVO) 52 (52): 6801-6806, 2011

      5 Eef van der Worp, "Sagittal height differences of frequent replacement silicone hydrogel contact lenses" Elsevier BV 38 (38): 157-162, 2015

      6 Stefano Giovanzana, "Sagittal height differences of disposable soft contact lenses" Springer Science and Business Media LLC 40 (40): 459-465, 2019

      7 LEON F. GARNER, "Sagittal Height of the Anterior Eye and Contact Lens Fitting" Ovid Technologies (Wolters Kluwer Health) 59 (59): 301-305, 1982

      8 MALCOLM M. BIBBY, "Sagittal Depth Considerations in the Selection of the Base Curve Radius of a Soft Contact Lens" Ovid Technologies (Wolters Kluwer Health) 56 (56): 407-413, 1979

      9 Gundal R, "Peripheral keratometry and soft contact lens fitting" 2 (2): 611-613, 1986

      10 Graeme Young, "Ocular sagittal height and soft contact lens fit" Elsevier BV 15 (15): 45-49, 1992

      11 Graeme Young, "Mathematical Model for Evaluating Soft Contact Lens Fit" Ovid Technologies (Wolters Kluwer Health) 91 (91): e167-e176, 2014

      12 Hom MM, "Manual contact lens prescribing and fitting" Butterworth-Heinemann 275-323, 2006

      13 Douthwaite WA, "Initial selection of soft contact lenses based on corneal characteristics" 28 (28): 202-205, 2002

      14 Adrian S. Bruce, "Influence of corneal topography on centration and movement of low water content soft contact lenses" Elsevier BV 21 (21): 45-49, 1994

      15 Seong JS, "Influence of base curve on the fit of soft contact lenses" 3 (3): 33-37, 1998

      16 Andrew Carkeet, "Field restriction and vignetting in contact lenses with opaque peripheries" Informa UK Limited 81 (81): 151-158, 1998

      17 Lee A. Hall, "Factors Affecting Corneoscleral Topography" Association for Research in Vision and Ophthalmology (ARVO) 54 (54): 3691-3701, 2013

      18 Mark J. Roseman, "Effects of base curve on the fit of thin, mid-water contact lenses" Elsevier BV 20 (20): 95-101, 1993

      19 Billert R, "Die praxisnahe Kontaktlinsenanpassung" Optonia 92-, 2014

      20 Langis Michaud, "Determining the soft contact lens sagittal depth to optimize fitting and comfort" Elsevier BV 41 : S93-S94, 2018

      21 Snyder AC, "Cosmetic extended-wear lenses:Considering sagittal differences between the lens and eye" 11 : 613-624, 1984

      22 Graeme Young, "Corneal Topography and Soft Contact Lens Fit" Ovid Technologies (Wolters Kluwer Health) 87 (87): 358-366, 2010

      23 Lowther GE, "Contact lenses:Procedures and techniques" Butterworth-Heinemann 24-28, 1992

      24 Caroline PJ, "Contact lens case reports:Three rules of scleral fitting"

      25 Caroline PJ, "Contact lens case reports:The effect of corneal diameter on soft lens fitting"

      26 Javier González-Cavada, "Base Curve Influence on the Fitting and Comfort of the Senofilcon A Contact Lens" Elsevier BV 2 (2): 90-93, 2009

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼