      Experimental identification of pressure drop characteristics at the shell side of an intermediate heat exchanger inside a prototype generation-IV sodium-cooled fast reactor

      한글로보기

      https://www.riss.kr/link?id=A107459223

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      <P><B>Abstract</B></P> <P>The flow characteristics at the shell side of a prototype intermediate heat exchanger (p-IHX) in a prototype generation-IV sodium-cooled fast reactor (PGSFR) were investigated experimentally in ...

      <P><B>Abstract</B></P> <P>The flow characteristics at the shell side of a prototype intermediate heat exchanger (p-IHX) in a prototype generation-IV sodium-cooled fast reactor (PGSFR) were investigated experimentally in this study. The shell side of the p-IHX consisted of an inlet window, tube bundles, grid plates, and an exit flow channel. Two different test facilities were newly constructed to identify the pressure drop characteristics due to the complicated configuration with minimized scaling distortion. An intermediate heat exchanger test loop for PGSFR (iHELP) was constructed to characterize the flow resistance of the tube bundle regions with the grid plates and inlet window. The iHELP test section with a slab-shaped cross section was manufactured with a 1/29.6 vol scale ratio by preserving the height of the p-IHX. The hydraulic diameter at the tube bundle regions, the porosity of the grid plates, and the configuration of the tube bundles were conserved. In addition, the Reynolds number was preserved, which determined the flow rate conditions for the iHELP experiments. To investigate the pressure drop characteristics of the exit flow channel (EC), an intermediate heat exchanger test loop for the exit flow channel (IEC) was built with a 1/5 linearly reduced length scale by preserving the geometry of the flow path based on the EC of the p-IHX. The Euler number was conserved with a 1/8 Reynolds number ratio corresponding to a 1/1 flow velocity ratio to the p-IHX for dynamic similarity. By using each test facility the experimental pressure drop data satisfying the experimental uncertainty requirements were obtained separately for the bundle and exit channel regions. The pressure drop at the shell side of the p-IHX under a wide range of flow rate conditions was determined by using the pressure drop results from the iHELP and the IEC test facilities, which would be useful in improving and validating the pressure drop correlations in the IHX design computational code (SHXSA).</P> <P><B>Highlights</B></P> <P> <UL> <LI> Test facility with 1/29.6 volume scale was built for simulating the tube bundle regions. </LI> <LI> Test facility with 1/5 length scale was constructed for simulating the exit flow channel. </LI> <LI> Pressure drop for the IHX shell side was determined by two different test facilities. </LI> <LI> Pressure drop for the IHX was precisely measured over a wide range of flow rates. </LI> </UL> </P>

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼