RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재

      Test turnaround Time for Complete Blood Cell Count using Delta and Panic Value Checks and the Q-flag Limit

      한글로보기

      https://www.riss.kr/link?id=A106016541

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Test turnaround time (TAT) is the lead time from reception to reporting. In the complete blood cell count (CBC), 4 units of the XE-2100 (Sysmex Corp., Japan) processed around 80% of quantity, 1 unit of the LH-780 (Beckman-Coulter Incorp., USA) process...

      Test turnaround time (TAT) is the lead time from reception to reporting. In the complete blood cell count (CBC), 4 units of the XE-2100 (Sysmex Corp., Japan) processed around 80% of quantity, 1 unit of the LH-780 (Beckman-Coulter Incorp., USA) processed around 10% and 1 unit of ADVIA-2120 (Siemens AG, Munich, Germany) processed around 10%. We analyzed the change in the TAT for the CBC for over 7 years, from January of 2005 to December of 2011. The delta check made alterations of delta to WBC, hemoglobin, hematocrit, platelet and metamyelocyte, however, did not made them to band neutrophil, eosinophil, basophil and monocyte. The panic value check made alterations of panic value to hemoglobin, hematocrit, platelet and monocyte. In the criteria of currently slide review, LH-780 and ADVI-2120 analyzers prepared suspect flags of "Blast, Imm NE2, Immature granulocyte, Imm NE1, Left shift, Variant lymphocyte, Atypical lymphocyte, Platelet clumps and NRBC". The New slide review in the XE-2100 analyzer altered the preparations of a smear slide more than a "Platelet clumps flag(${\geq}200unit$), a single flag excluding the "Platelet clumps flag (${\geq}250unit$) and a multiple flag (${\geq}200unit$)". Also, below the 240 unit, medical technologists prepared manual slides selectively according to their evaluations. The automatic reporting rate was 33.4% without alterations, whereas it was 41.0% without alterations, and was thus improved by 7.6%. The slide review rate was 15.2% before using the Q-flag limit, whereas it was 12.1% for a reduce 3.1%. TAT was 45 minutes without the creation alterations of the delta and panic value checks, whereas it was 35 minutes after making alterations of the delta and panic value checks and thus was shortened by 10 minutes. We came to the conclusion that the establishment and operation of delta and panic value checks and slide review criteria suitable for laboratory environment can reduce unnecessary smear slides, re-checking, re-sampling, re-testing, telephone inquiries and concentrated workloads during specific times of the day.

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼