      Development and Evaluation of the Utility of a Respiratory Monitoring and Visual Feedback System for Radiotherapy Using Machine Vision Technology

      한글로보기

      https://www.riss.kr/link?id=A108082324

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Background: We developed a machine vision technology program that tracks patients’ realtime breathing and automatically analyzes their breathing patterns.Materials and Methods: To evaluate its potential for clinical application, the image tracking p...

      Background: We developed a machine vision technology program that tracks patients’ realtime breathing and automatically analyzes their breathing patterns.Materials and Methods: To evaluate its potential for clinical application, the image tracking performance and accuracy of the program were analyzed using a respiratory motion phantom. Changes in the stability and regularity of breathing were observed in healthy adult volunteers according to whether the breathing pattern mirrored the breathing guidance.Results and Discussion: Displacement within a few millimeters was observed in real-time with a clear resolution, and the image tracking ability was excellent. This result was consistent even in the sections where breathing patterns changed rapidly. In addition, the respiratory gating method that reflected the individual breathing patterns improved breathing stability and regularity in all volunteers.Conclusion: The findings of this study suggest that this technology can be used to set the appropriate window and the range of internal target volume by reflecting the patient’s breathing pattern during radiotherapy planning. However, further studies in clinical populations are required to validate this technology.

      더보기

      참고문헌 (Reference)

      1 Linthout N, "Treatment delivery time optimization of respiratory gated radiation therapy by application of audio-visual feedback" 91 (91): 330-335, 2009

      2 Prunaretty J, "Tracking, gating, free-breathing, which technique to use for lung stereotactic treatments? A dosimetric comparison" 24 (24): 97-104, 2019

      3 Murphy MJ, "Tracking moving organs in real time" 14 (14): 91-100, 2004

      4 Keall PJ, "The management of respiratory motion in radiation oncology report of AAPM Task Group 76" 33 (33): 3874-3900, 2006

      5 Li XA, "Technical and dosimetric aspects of respiratory gating using a pressure-sensor motion monitoring system" 33 (33): 145-154, 2006

      6 Neicu T, "Synchronized moving aperture radiation therapy (SMART) : improvement of breathing pattern reproducibility using respiratory coaching" 51 (51): 617-636, 2006

      7 He P, "Respiratory motion management using audio-visual biofeedback for respiratorygated radiotherapy of synchrotron-based pulsed heavy-ion beam delivery" 41 (41): 111708-, 2014

      8 Nelson C, "Respiration-correlated treatment delivery using feedback-guided breath hold : a technical study" 32 (32): 175-181, 2005

      9 Vedam SS, "Quantifying the predictability of diaphragm motion during respiration with a noninvasive external marker" 30 (30): 505-513, 2003

      10 Webb S, "Motion effects in (intensity modulated) radiation therapy:a review" 51 (51): R403-R425, 2006

      1 Linthout N, "Treatment delivery time optimization of respiratory gated radiation therapy by application of audio-visual feedback" 91 (91): 330-335, 2009

      2 Prunaretty J, "Tracking, gating, free-breathing, which technique to use for lung stereotactic treatments? A dosimetric comparison" 24 (24): 97-104, 2019

      3 Murphy MJ, "Tracking moving organs in real time" 14 (14): 91-100, 2004

      4 Keall PJ, "The management of respiratory motion in radiation oncology report of AAPM Task Group 76" 33 (33): 3874-3900, 2006

      5 Li XA, "Technical and dosimetric aspects of respiratory gating using a pressure-sensor motion monitoring system" 33 (33): 145-154, 2006

      6 Neicu T, "Synchronized moving aperture radiation therapy (SMART) : improvement of breathing pattern reproducibility using respiratory coaching" 51 (51): 617-636, 2006

      7 He P, "Respiratory motion management using audio-visual biofeedback for respiratorygated radiotherapy of synchrotron-based pulsed heavy-ion beam delivery" 41 (41): 111708-, 2014

      8 Nelson C, "Respiration-correlated treatment delivery using feedback-guided breath hold : a technical study" 32 (32): 175-181, 2005

      9 Vedam SS, "Quantifying the predictability of diaphragm motion during respiration with a noninvasive external marker" 30 (30): 505-513, 2003

      10 Webb S, "Motion effects in (intensity modulated) radiation therapy:a review" 51 (51): R403-R425, 2006

      11 Marks MK, "Measurement of respiratory rate and timing using a nasal thermocouple" 11 (11): 159-164, 1995

      12 Mageras GS, "Measurement of lung tumor motion using respiration-correlated CT" 60 (60): 933-941, 2004

      13 Sharma G, "Image recognition system using geometric matching and contour detection" 51 (51): 48-53, 2012

      14 Storck K, "Heat transfer evaluation of the nasal thermistor technique" 43 (43): 1187-1191, 1996

      15 Moore D, "Guidelines for using the ABC system on the Elekta for respiratory gating treatment" 9 (9): 61-71, 2018

      16 Shirato H, "Four-dimensional treatment planning and fluoroscopic real-time tumor tracking radiotherapy for moving tumor" 48 (48): 435-442, 2000

      17 Chen QS, "Fluoroscopic study of tumor motion due to breathing : facilitating precise radiation therapy for lung cancer patients" 28 (28): 1850-1856, 2001

      18 Shi C, "Evaluation of the new respiratory gating system" 1 (1): 127-133, 2017

      19 Stock M, "Development and application of a real-time monitoring and feedback system for deep inspiration breath hold based on external marker tracking" 33 (33): 2868-2877, 2006

      20 Shimizu S, "Detection of lung tumor movement in real-time tumor-tracking radiotherapy" 51 (51): 304-310, 2001

      21 Suramo I, "Cranio-caudal movements of the liver, pancreas and kidneys in respiration" 25 (25): 129-131, 1984

      22 Yoshitake T, "Breath-hold monitoring and visual feedback for radiotherapy using a charge-coupled device camera and a head-mounted display : system development and feasibility" 26 (26): 50-55, 2008

      23 George R, "Audio-visual biofeedback for respiratory-gated radiotherapy : impact of audio instruction and audio-visual biofeedback on respiratory-gated radiotherapy" 65 (65): 924-933, 2006

      24 Gagel B, "Active breathing control (ABC) : determination and reduction of breathing-induced organ motion in the chest" 67 (67): 742-749, 2007

      25 Yoshitake T, "A clinical evaluation of visual feedback-guided breath-hold reproducibility of tumor location" 54 (54): 7171-7182, 2009

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2026 평가예정 재인증평가 신청대상 (재인증)
      2020-01-01 평가 등재학술지 유지 (재인증) KCI등재
      2017-01-01 평가 등재학술지 유지 (계속평가) KCI등재
      2016-09-12 학술지명변경 외국어명 : Journal of Radiation Protection -> Journal of Radiation Protection and Research KCI등재
      2013-01-01 평가 등재 1차 FAIL (등재유지) KCI등재
      2010-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2009-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2008-03-31 학술지명변경 외국어명 : 미등록 -> Journal of Radiation Protection KCI등재후보
      2008-01-01 평가 등재후보학술지 유지 (등재후보2차) KCI등재후보
      2007-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2006-01-01 평가 등재후보학술지 유지 (등재후보2차) KCI등재후보
      2005-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2003-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.2 0.2 0.18
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.27 0.24 0.403 0.03
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼