      Maintenance of Platelet Counts with Low Level QC Materials and the Change in P-LCR according to Hemolysis with XN-9000

      한글로보기

      https://www.riss.kr/link?id=A105959748

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      The platelet count in clinical laboratories is essential for the diagnosis and treatment of hemostasis abnormalities, and accurate platelet counting in the low count range is of prime importance for deciding if a platelet transfusion is needed and for...

      The platelet count in clinical laboratories is essential for the diagnosis and treatment of hemostasis abnormalities, and accurate platelet counting in the low count range is of prime importance for deciding if a platelet transfusion is needed and for monitoring after chemotherapy. Quality control is designed to reduce and correct any deficiencies in the internal analytical process of a clinical laboratory prior to the release of patient results. Fragmented erythrocytes are the major confusing factors for platelet counting because of their similar size to platelets. The authors found that the low range QC values were out of 2SD with a Sysmex automatic analyzer in internal quality control process. Thus far, there has been little discussion on the relationship between hemolysis and the platelet parameters. Therefore, this study focused on the performance of automated platelet counts, including the PLT-F, the PLT-I, and PLT-O methods at the low platelet range using the low level QC materials and compared the 5 platelet parameters with the hemolyzed samples. The results showed that the CV was the smallest with PLT-F and P-LCR increased from 18.4 to 31.9% in the hemolysis samples. These results indicate that a more accurate estimation of the platelet counts can be achieved using the PLT-F method than the PLT-I method at the low platelet range. The use of the PLT-F system improves the confidence of results in low platelets samples in a routine hematology laboratory. The results suggest that P-LCR is a new parameter in assessing samples when the specimen is suspected of hemolysis and deterioration. Nevertheless, further studies will be needed to establish the relationship with P-LCR and hemolysis using human blood specimens.

      더보기

      참고문헌 (Reference)

      1 Niethammer AG, "Use of the platelet histogram maximum in evaluating thrombocytopenia" 60 : 19-23, 1999

      2 Briggs C, "The most accurate platelet count on the Sysmex XE-2100: optical or impedance?" 26 : 157-158, 2004

      3 Tantanate C, "Spuriously high platelet counts by various automated hematology analyzers in patient with disseminated intravascular coagulation" 53 : 257-259, 2015

      4 Zandecki M, "Spurious counts and sprious results on haematology analyzers" 29 : 4-20, 2007

      5 Grotto H, "Platelet larger cell ratio(P-LCR)in patients with dyslipidemia" 26 : 347-349, 2004

      6 Tanaka Y, "Performance evaluation of platelet counting by novel fluorescent dye staining in the XN-series automated hematology analyzers" 28 : 341-348, 2014

      7 Tantanate C, "Performance evaluation of automated impedance and optical fluorescence platelet counts compared with international reference method in patients with thalassemia" 141 : 830-836, 2017

      8 Briggs C, "Performance evaluation of Sysmex haematology XN modular system" 65 : 1024-1030, 2012

      9 Briggs C, "New quantitative parameters on a recently introduced automated blood cell counter : the XE2100" 22 : 345-350, 2000

      10 Schoorl M, "New fluorescent method(PLT-F)on Sysmex XN2000 hematology analyzer achieved higher accuracy in low platelet counting" 140 : 495-499, 2013

      1 Niethammer AG, "Use of the platelet histogram maximum in evaluating thrombocytopenia" 60 : 19-23, 1999

      2 Briggs C, "The most accurate platelet count on the Sysmex XE-2100: optical or impedance?" 26 : 157-158, 2004

      3 Tantanate C, "Spuriously high platelet counts by various automated hematology analyzers in patient with disseminated intravascular coagulation" 53 : 257-259, 2015

      4 Zandecki M, "Spurious counts and sprious results on haematology analyzers" 29 : 4-20, 2007

      5 Grotto H, "Platelet larger cell ratio(P-LCR)in patients with dyslipidemia" 26 : 347-349, 2004

      6 Tanaka Y, "Performance evaluation of platelet counting by novel fluorescent dye staining in the XN-series automated hematology analyzers" 28 : 341-348, 2014

      7 Tantanate C, "Performance evaluation of automated impedance and optical fluorescence platelet counts compared with international reference method in patients with thalassemia" 141 : 830-836, 2017

      8 Briggs C, "Performance evaluation of Sysmex haematology XN modular system" 65 : 1024-1030, 2012

      9 Briggs C, "New quantitative parameters on a recently introduced automated blood cell counter : the XE2100" 22 : 345-350, 2000

      10 Schoorl M, "New fluorescent method(PLT-F)on Sysmex XN2000 hematology analyzer achieved higher accuracy in low platelet counting" 140 : 495-499, 2013

      11 Park Y, "Mean platelet volume as an indicator of platelet activation : methodological issues" 13 : 301-306, 2002

      12 Saliba RM, "Leukemia burden delays lymphocyte and platelet recovery after allo-SCT for AML" 43 : 685-692, 2009

      13 Siegenthaler M, "Images in clinical medicine : spurious platelet count" 354 : 1936-, 2006

      14 Briggs C, "Continuing developments with the automated platelet count" 29 : 77-91, 2007

      15 Segal HC, "Accuracy of platelet counting haematology analyzers in severe thrombocytopenia and potential impact on platelet transfusion" 128 : 520-525, 2005

      16 Wada A, "Accuracy of a new platelet count system(PLT0F)depends on the staining property of its reagents" 10 : 1-13, 2015

      더보기

      동일학술지(권/호) 다른 논문

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2026 평가예정 재인증평가 신청대상 (재인증)
      2020-01-01 평가 등재학술지 유지 (재인증) KCI등재
      2017-01-01 평가 등재학술지 선정 (계속평가) KCI등재
      2016-01-01 평가 등재후보학술지 유지 (계속평가) KCI등재후보
      2015-01-08 학술지명변경 한글명 : 대한임상검사학회지 -> 대한임상검사과학회지
      외국어명 : 미등록 -> Korean Journal of Clinical Laboratory Science
      KCI등재후보
      2014-06-25 학회명변경 한글명 : 대한임상검사학회 -> 대한임상검사과학회
      영문명 : The Korean Society for Clinical Laboratory Science -> Korean Society for Clinical Laboratory Science
      KCI등재후보
      2014-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      2004-12-17 학회명변경 영문명 : The Korean Society Of Biomedical Laboratory Science -> The Korean Society for Clinical Laboratory Science
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.43 0.43 0.36
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.31 0.28 0.34 0.12
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼