The LNG cold power generation system was designed in favor of the Rankine cycle. The thermodynamic properties are calculated with the Peng-Robinson model. The feed gas conditions of LNG Test Bed Train No.1 were incorporated in the steady state simulat...
The LNG cold power generation system was designed in favor of the Rankine cycle. The thermodynamic properties are calculated with the Peng-Robinson model. The feed gas conditions of LNG Test Bed Train No.1 were incorporated in the steady state simulation of the power generation system. The commercial tool Aspen HYSYS made all the analysis by using the provided input data and some necessary assumptions. In particular, this paper reviewed the process of the rankine cycle including heat duty of heat exchanger, flow rate of refrigerant for optimal refrigerant.