      Insulation Design Standards for Protection of Power System against Lightning in Korea Electric Power Corporation = 낙뢰로부터 전력설비 보호를 위한 한전의 절연설계 기준

      한글로보기

      https://www.riss.kr/link?id=A76532245

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      As it has been reported that more than 60% of transmission line faults occurs due to lightning strokes, lighting is one of concerned issues in electric power utility company. Most of transmission line is double circuit in Korea. Double circuit outages...

      As it has been reported that more than 60% of transmission line faults occurs due to lightning strokes, lighting is one of concerned issues in electric power utility company. Most of transmission line is double circuit in Korea. Double circuit outages account for 33.7 percent of total lightning faults from 1996 to 2004. Even though transmission fault might be cleared shortly by protective system, it could deteriorate the power quality accompanied with sag or flicker. Moreover, double circuit fault may lead to more aggravated situation, for instance, blackout. To protect transmission lines from lightning stroke, reduction of tower footing resistance, multiple ground wires and unbalanced insulation in double circuit lines have been adopted. In this paper, we would like to introduce insulation design standards for lightning protection of Korea Electric Power Corporation.

      더보기

      목차 (Table of Contents)

      • Abstract
      • 1. Introduction
      • 2. Power System and Lightning in KOREA
      • 3. Design Standards for Transmission Line
      • 4. Design Standards for Substation
      • Abstract
      • 1. Introduction
      • 2. Power System and Lightning in KOREA
      • 3. Design Standards for Transmission Line
      • 4. Design Standards for Substation
      • 5. Conclusion
      • [References]
      • 저자소개
      더보기

      참고문헌 (Reference)

      1 E.B.Shim, "The prevention of simultaneous trip on the 154 kV double circuit transmission line by lightning" 2004.

      2 Commonwelth Associate Inc, "Planning and design studies for 345 kV transmission system of Korea electric company" 1969-, ppv-2

      3 K. Ishida et al, "Development of a 500 kV transmission line arrester and its characteristics" 7 (7): 1992-, pp.1265-1274

      4 T. Gawamura. et al, "Development of Metal-Oxide transmission line arrester and its effectiveness" -201, 1994

      5 KEPCO, "Design standard for insulation coordination of Korea electric power corporation" 2001.

      6 KEPCO, "Design standard for grounding of 154 kV of Korea electric power corporation" 2001.

      7 C.H.Shih,et al, "Application of special surge arresters on 138 kV lines of appalachian power company" no.10 : 1985

      8 KEPRI, "A study for establishment of specification of 345kV and 154kV Gapless surge arrester" 2000

      9 KEPRI, "A Insulation coordination study of 765 kV transmission system" 1995

      1 E.B.Shim, "The prevention of simultaneous trip on the 154 kV double circuit transmission line by lightning" 2004.

      2 Commonwelth Associate Inc, "Planning and design studies for 345 kV transmission system of Korea electric company" 1969-, ppv-2

      3 K. Ishida et al, "Development of a 500 kV transmission line arrester and its characteristics" 7 (7): 1992-, pp.1265-1274

      4 T. Gawamura. et al, "Development of Metal-Oxide transmission line arrester and its effectiveness" -201, 1994

      5 KEPCO, "Design standard for insulation coordination of Korea electric power corporation" 2001.

      6 KEPCO, "Design standard for grounding of 154 kV of Korea electric power corporation" 2001.

      7 C.H.Shih,et al, "Application of special surge arresters on 138 kV lines of appalachian power company" no.10 : 1985

      8 KEPRI, "A study for establishment of specification of 345kV and 154kV Gapless surge arrester" 2000

      9 KEPRI, "A Insulation coordination study of 765 kV transmission system" 1995

      더보기

      동일학술지(권/호) 다른 논문

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2007-01-01 평가 학술지 통합(등재유지)
      2006-01-01 평가 등재학술지 유지(등재유지) KCI등재
      2004-01-01 평가 등재학술지 유지(등재유지) KCI등재
      2001-07-01 평가 등재학술지 선정(등재후보2차) KCI등재
      1999-01-01 평가 등재후보학술지 선정(신규평가) KCI등재후보
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼