RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재 SCOPUS

      Diagnostic efficacy of a modified low-dose acquisition protocol for the preoperative evaluation of mini-implant sites

      한글로보기

      https://www.riss.kr/link?id=A105117399

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Purpose: The objective of this study was to compare the outcomes of surgical mini-implant placement when potential mini-implant sites were scanned using a lower-dose 180° acquisition protocol versus a conventional 360° acquisition protocol. Materia...

      Purpose: The objective of this study was to compare the outcomes of surgical mini-implant placement when potential mini-implant sites were scanned using a lower-dose 180° acquisition protocol versus a conventional 360° acquisition protocol.
      Materials and Methods: Ten dentate human skulls were used to provide sites for potential mini-implant placement. The sites were randomly divided into 2 groups: 360° and 180° cone-beam computed tomography (CBCT) acquisition protocols. A small-volume 180° CBCT scan and a 360° CBCT scan of each site were acquired using a Morita Accuitomo-170 CBCT machine and then a mini-implant was placed. A follow-up 360° CBCT scan was done as a gold standard to evaluate the location of the mini-implant and root perforation. Two raters evaluated the scans.
      Results: Ninety-eight percent of the mini-implants placed did not perforate any root structure. Two percent of the sites had an appearance suggestive of perforation. On a Likert scale, both raters agreed that their subjective evaluation of the diagnostic quality of the protocols, ability to make and read measurements of the sites, and preferences for the specified diagnostic task were comparable. The Cohen kappa showed high inter-rater and intrarater agreement.
      Conclusion: In this ex vivo study, we found that the 180° rotational acquisition was as effective as the conventional 360° rotational acquisition for the preoperative evaluation of potential mini-implant sites.

      더보기

      참고문헌 (Reference)

      1 Poggio PM, "‘‘Safe zones’’: a guide for miniscrew positioning in the maxillary and mandibular arch" 76 : 191-197, 2006

      2 Scarfe WC, "What is cone-beam CT and how does it work?" 52 : 707-730, 2008

      3 Upadhyay M, "Treatment effects of mini-implants for en-masse retraction of anterior teeth in bialveolar dental protrusion patients: a randomized controlled trial" 134 : 18-29.e1, 2008

      4 Cope JB, "Temporary anchorage devices in orthodontics: a paradigm shift" 11 : 3-9, 2005

      5 Bonnick AM, "Technological advances in nontraditional orthodontics" 55 : 571-584, 2011

      6 McCabe P, "Root perforation associated with the use of a miniscrew implant used for orthodontic anchorage: a case report" 45 : 678-688, 2012

      7 Ludlow JB, "Patient risk related to common dental radiographic examinations: the impact of 2007 International Commission on Radiological Protection recommendations regarding dose calculation" 139 (139): 1237-1243, 2008

      8 Bechara B, "Number of basis images effect on detection of root fractures in endodontically treated teeth using a cone beam computed tomography machine: an in vitro study" 115 : 676-681, 2013

      9 Upadhyay M, "Mini-implant anchorage for en-masse retraction of maxillary anterior teeth: a clinical cephalometric study" 134 : 803-810, 2008

      10 Brisceno CE, "Healing of the roots and surrounding structures after intentional damage with miniscrew implants" 135 : 292-301, 2009

      1 Poggio PM, "‘‘Safe zones’’: a guide for miniscrew positioning in the maxillary and mandibular arch" 76 : 191-197, 2006

      2 Scarfe WC, "What is cone-beam CT and how does it work?" 52 : 707-730, 2008

      3 Upadhyay M, "Treatment effects of mini-implants for en-masse retraction of anterior teeth in bialveolar dental protrusion patients: a randomized controlled trial" 134 : 18-29.e1, 2008

      4 Cope JB, "Temporary anchorage devices in orthodontics: a paradigm shift" 11 : 3-9, 2005

      5 Bonnick AM, "Technological advances in nontraditional orthodontics" 55 : 571-584, 2011

      6 McCabe P, "Root perforation associated with the use of a miniscrew implant used for orthodontic anchorage: a case report" 45 : 678-688, 2012

      7 Ludlow JB, "Patient risk related to common dental radiographic examinations: the impact of 2007 International Commission on Radiological Protection recommendations regarding dose calculation" 139 (139): 1237-1243, 2008

      8 Bechara B, "Number of basis images effect on detection of root fractures in endodontically treated teeth using a cone beam computed tomography machine: an in vitro study" 115 : 676-681, 2013

      9 Upadhyay M, "Mini-implant anchorage for en-masse retraction of maxillary anterior teeth: a clinical cephalometric study" 134 : 803-810, 2008

      10 Brisceno CE, "Healing of the roots and surrounding structures after intentional damage with miniscrew implants" 135 : 292-301, 2009

      11 Papageorgiou SN, "Failure rates and associated risk factors of orthodontic miniscrew implants: a meta-analysis" 142 : 577-595.e7, 2012

      12 Hembree M, "Effects of intentional damage of the roots and surrounding structures with miniscrew implants" 135 : 280.e1-280.e9, 2009

      13 Pauwels R, "Effective dose range for dental cone beam computed tomography scanners" 81 : 267-271, 2012

      14 Lennon S, "Diagnostic accuracy of limited-volume cone-beam computed tomography in the detection of periapical bone loss: 360° scans versus 180° scans" 44 : 1118-1127, 2011

      15 Yadav S, "Diagnostic accuracy of 2 cone-beam computed tomography protocols for detecting arthritic changes in temporomandibular joints" 147 : 339-344, 2015

      16 Landin M, "A comparative study between currently used methods and small volume-cone beam tomography for surgical placement of mini implants" 85 : 446-453, 2015

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2019-03-27 학회명변경 한글명 : 대한구강악안면방사선학회 -> 대한영상치의학회 KCI등재
      2012-04-16 학술지명변경 한글명 : 대한구강악안면방사선학회지 -> Imaging Science in Dentistry KCI등재
      2011-03-29 학술지명변경 외국어명 : Korean Journal of Oral and Maxillofacial Radiology -> Imaging Science in Dentistry KCI등재
      2010-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2008-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2006-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2003-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2002-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2000-07-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.12 0.12 0.11
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.11 0.12 0.217 0.02
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼