RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재

      플레이트의 소성변형 과정이 재건술에서 플레이트 안정성에 미치는 영향

      한글로보기

      https://www.riss.kr/link?id=A102075069

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Conventional bent plate used in mandibular reconstruction surgery needs safety verification since its mechanical properties are changed due to the plastic deformation during the bending process. In this study we investigate stability of the plasticall...

      Conventional bent plate used in mandibular reconstruction surgery needs safety verification since its mechanical properties are changed due to the plastic deformation during the bending process. In this study we investigate stability of the plastically deformed plate and the plate with the same shape without plastic deformation through the finite element analysis(FEA). First we simulate the process of plate bending to fit the defect in patient. Then, the other plate is modelled to represent a customized plate with the same shape of the plastically deformed one, but without any residual stresses from plastic deformation. After binding these plates to the mandible, we conduct the masticatory simulation. Finally, we compare the resulting Von Mises stress of the customized plate and of the bent plate. The bent plate shows much higher stress than the customized one due to the residual stresses form the bending process. The study shows that plastic deformation in the plate may decrease the safety of the reconstruction surgery.

      더보기

      목차 (Table of Contents)

      • ABSTRACT
      • 1. 서론
      • 2. 유한요소해석 모델
      • 3. 결론
      • References
      • ABSTRACT
      • 1. 서론
      • 2. 유한요소해석 모델
      • 3. 결론
      • References
      더보기

      참고문헌 (Reference)

      1 Gardner, M.J, "The Mechanical behavior of Locking Compression Plates Compared with Dynamic Compression Plates in A Cadaver Radius Model" 19 : 597-603, 2005

      2 Stoffel, K, "Oblique Screws at the Plate Ends Increase the Fixation Strength in Synthetic Bone Test Medium" 18 : 611-616, 2012

      3 Mesnard, M, "Muscular and Articular Forces Exerted on the Mandible" 199-204, 2010

      4 Bathe, K.-J, "Insight into an Implicit Time Integration Scheme for Structural Dynamics" 98-99 : 1-6, 2012

      5 Aquilina, P, "Finite Element Analysis of Three Patterns of Internal Fixation of Fractures of the Mandibular Condyle" 3883 : 6-11, 2012

      6 "DASSAULT SYSTEMS SIMULIA"

      7 Zenner, H, "Cyclic Material behavior of Magnesium Die Castings and Extrusions" 24 : 1255-1260, 2002

      8 Cook, R.D, "Concepts and Applications of Finite Element Analysis" John Wiley & Sons. Inc 2002

      9 Mesnard, M, "Biomechanical Analysis Comparing Natural and Alloplastic Temporomandibular Joint Replacement Using a Finite Element Model" 69 : 1008-1017, 2011

      10 Gunwoo, N, "An Explicit Time Integration Scheme for the Analysis of Wave Propagations" 129 : 178-193, 2013

      1 Gardner, M.J, "The Mechanical behavior of Locking Compression Plates Compared with Dynamic Compression Plates in A Cadaver Radius Model" 19 : 597-603, 2005

      2 Stoffel, K, "Oblique Screws at the Plate Ends Increase the Fixation Strength in Synthetic Bone Test Medium" 18 : 611-616, 2012

      3 Mesnard, M, "Muscular and Articular Forces Exerted on the Mandible" 199-204, 2010

      4 Bathe, K.-J, "Insight into an Implicit Time Integration Scheme for Structural Dynamics" 98-99 : 1-6, 2012

      5 Aquilina, P, "Finite Element Analysis of Three Patterns of Internal Fixation of Fractures of the Mandibular Condyle" 3883 : 6-11, 2012

      6 "DASSAULT SYSTEMS SIMULIA"

      7 Zenner, H, "Cyclic Material behavior of Magnesium Die Castings and Extrusions" 24 : 1255-1260, 2002

      8 Cook, R.D, "Concepts and Applications of Finite Element Analysis" John Wiley & Sons. Inc 2002

      9 Mesnard, M, "Biomechanical Analysis Comparing Natural and Alloplastic Temporomandibular Joint Replacement Using a Finite Element Model" 69 : 1008-1017, 2011

      10 Gunwoo, N, "An Explicit Time Integration Scheme for the Analysis of Wave Propagations" 129 : 178-193, 2013

      11 "AOFoundation"

      12 Kowalski, M.J, "A Comparative Biomechanical Evaluation of a Noncontacting Plate and Currently Used Devices for Tibial Fixation" 40 : 5-9, 1996

      13 Kornoer, J, "A Biomechanical Evaluation of Methods of Distal Humerus Fracture Fixation Using Locking Compression Plates Versus Conventional Reconstruction Plates" 18 : 286-293, 2004

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2026 평가예정 재인증평가 신청대상 (재인증)
      2020-01-01 평가 등재학술지 유지 (재인증) KCI등재
      2017-01-01 평가 등재학술지 유지 (계속평가) KCI등재
      2016-06-13 학회명변경 한글명 : 한국CAD/CAM학회 -> 한국CDE학회
      영문명 : Society Of Cadcam Engineers -> Society for Computational Design and Engineering
      KCI등재
      2016-06-13 학술지명변경 한글명 : 한국CAD/CAM학회 논문집 -> 한국CDE학회 논문집
      외국어명 : 미등록 -> Korean Journal of Computational Design and Engineering
      KCI등재
      2013-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2010-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2008-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2006-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2005-10-04 학술지등록 한글명 : 한국CAD/CAM학회 논문집
      외국어명 : 미등록
      KCI등재
      2004-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2001-07-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      1999-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.35 0.35 0.33
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.26 0.24 0.553 0.02
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼