RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      Aptamer-Based Immunosensor on the ZnO Nanorods Networks

      한글로보기

      https://www.riss.kr/link?id=A107600929

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      <P>This paper presents the fabrication and characteristics of a new aptamer-based electrochemical immunosensor on the patterned zinc oxide nanorod networks (ZNNs) for detecting thrombin. Aptamers are single-stranded RNA or DNA sequence that bind...

      <P>This paper presents the fabrication and characteristics of a new aptamer-based electrochemical immunosensor on the patterned zinc oxide nanorod networks (ZNNs) for detecting thrombin. Aptamers are single-stranded RNA or DNA sequence that binds to target materials with high specificity and affinity. An antibody-antigen-aptamer sandwich structure was employed to this immunosensor for detecting thrombin. First, hydrothermally grown ZNNs were patterned on the patterned 0.02 cm2 Au/Ti electrodes on a glass substrate by lift-off process. The high isoelectric point (IEP, approximately 9.5) of nanostructured ZnO makes it suitable for immobilizing proteins with low IEP. Then 5 microL of the 500 nM antibody was immobilized on the ZNNs electrode. 5 micro/L of the mixture of 1 microM aptamer labeled by ferrocene (Fc) and thrombin was dropped on the electrode for antibody-antigen binding. The peak oxidation currents of the immunosensors at various thrombin concentrations were measured by using cyclic voltammetry. The peak oxidation current was observed at 340 mV versus Ag/AgCl electrode, and the peak oxidation current increased linearly from 62.26 nA to 354.13 nA with the logarithmic concentration of thrombin in the range from 100 pM to 250 nM. Fabrication of an aptamer-based immunosensor for thrombin detection is a new attempt and the characteristics of the fabricated immunosensors showed that the fabricated aptamer-baded immunosensor worked electrochemically well and had a low detection limit (approximately 91.04 pM) and good selectivity.</P>

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼