RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재

      치과용 지르코니아의 in vitro 및 in vivo 생물학적 평가

      한글로보기

      https://www.riss.kr/link?id=A100409063

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Recently, zirconia ceramics have been extensively used as the artificial tooth in modern dentistry on account of their excellent mechanical properties and good esthetics. The purpose of this study was to evaluate biocompatibility of zirconia ceramics ...

      Recently, zirconia ceramics have been extensively used as the artificial tooth in modern dentistry on account of their excellent mechanical properties and good esthetics. The purpose of this study was to evaluate biocompatibility of zirconia ceramics using agar diffusion test, acute systemic toxicity, intracutaneous test and local lymph node assay(LLNA). For in vitro test, the agar diffusion assay was used sintered zirconia specimens (In-ceram YZ-55, VITA Co., Bad sackingen, Germany) were performed according to ISO 7405. For in vivo test, three different tests were carried out and samples were prepared according to ISO 10993-12 for all of the test. Acute systemic toxicity test and Intracutaneous test, were performed according to ISO 10993-11 and ISO 10993-10. The murine local lymph node assay test was performed according to OECD guide line 442 B. The overall criterion for the cytotoxicity of zirconia sample was 0. For the acute systemic toxicity test, no symptoms were observed during the visual observation of the animal. For the intracutaneous irritation test, there was no redness and swellings on the reaction sites. The result of LLNA test, the samples extractions in polar solvents showed average OD value of 1.078 and those in non-polar solvents showed average OD value of 1.059. The partially stabilized zirconia materials were proved to be biocompatible. The results of both in vitro and in vivo test concluded that the zirconia materials were biocompatible.

      더보기

      참고문헌 (Reference)

      1 OECD, "skin sensitization:Local Lymph Node Assay : BrdU-ELISA, Test Guideline No. 442 B, Guidelines for the testing of chemicals"

      2 Sollazzo V, "Zirconium oxide coating improves implant osseointegration in vivo" 24 : 357-361, 2008

      3 Keisuke N, "Zirconia as a dental implant abutment material : a systematic review" 23 : 299-309, 2010

      4 Nakamura K, "Zirconia as a dental implant abutment material : A systemic review" 23 : 299-309, 2010

      5 Yoichiro I, "Tissue compatibility and stability of a new zirconia ceramic invivo" 68 : 322-326, 1992

      6 Welender M, "The mucosal barrier at implant abutments of different materials" 19 : 635-641, 2008

      7 Hallmann L, "The influence of grain size on low-temperature degradation of dental zirconia" 100B : 447-456, 2011

      8 Schley JS, "Survival probability of zirconiabased fixed dental prostheses up to 5 yr : a systematic review of the literature" 118 : 443-450, 2010

      9 Christel P, "Mechanical properties and short-term in-vivo evaluation of yttrium-oxide-partially-stabilized zirconia" 23 : 45-61, 1989

      10 Covacci V, "In vitro evaluation of the mutagenic and carcinogenic power of high purity zirconia ceramic" 20 : 371-376, 1999

      1 OECD, "skin sensitization:Local Lymph Node Assay : BrdU-ELISA, Test Guideline No. 442 B, Guidelines for the testing of chemicals"

      2 Sollazzo V, "Zirconium oxide coating improves implant osseointegration in vivo" 24 : 357-361, 2008

      3 Keisuke N, "Zirconia as a dental implant abutment material : a systematic review" 23 : 299-309, 2010

      4 Nakamura K, "Zirconia as a dental implant abutment material : A systemic review" 23 : 299-309, 2010

      5 Yoichiro I, "Tissue compatibility and stability of a new zirconia ceramic invivo" 68 : 322-326, 1992

      6 Welender M, "The mucosal barrier at implant abutments of different materials" 19 : 635-641, 2008

      7 Hallmann L, "The influence of grain size on low-temperature degradation of dental zirconia" 100B : 447-456, 2011

      8 Schley JS, "Survival probability of zirconiabased fixed dental prostheses up to 5 yr : a systematic review of the literature" 118 : 443-450, 2010

      9 Christel P, "Mechanical properties and short-term in-vivo evaluation of yttrium-oxide-partially-stabilized zirconia" 23 : 45-61, 1989

      10 Covacci V, "In vitro evaluation of the mutagenic and carcinogenic power of high purity zirconia ceramic" 20 : 371-376, 1999

      11 International Organization for standardization, "ISO 10993-5: Biological evaluation of medical devicespart 5 : Tests for in vitro cytotoxicity"

      12 International Organization for standardization, "ISO 10993-11: Biological evaluation of medical devices-part 11 : Tests for systemic toxicity"

      13 International Organization for standardization, "ISO 10993-10: Biological evaluation of medical devices-part 10 : Tests for irritation and skin sensitization"

      14 Zarone F, "From porcelain-fused-to-metal to zirconia : Clinical and experimental considerations" 27 : 83-96, 2011

      15 Li J, "Evaluation of biocompatibility of various ceramic powders with human fibroblasts in vitro" 12 : 197-201, 1993

      16 Schmitter M, "Clinical performance of longspan zirconia frameworks for fixed dental prostheses : 5-year results" 39 : 552-557, 2012

      17 Hideki W, "Biological reaction to alumina, zirconia, titanium and polyethylene particles implanted onto murine calvaria" 24 : 3655-3661, 2003

      더보기

      동일학술지(권/호) 다른 논문

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2026 평가예정 재인증평가 신청대상 (재인증)
      2020-01-01 평가 등재학술지 유지 (재인증) KCI등재
      2017-01-01 평가 등재학술지 유지 (계속평가) KCI등재
      2014-11-11 학회명변경 한글명 : 대한치과기재학회 -> 대한치과재료학회
      영문명 : The Korea Research Society For Dental Materials -> Korean Society For Dental Materials
      KCI등재
      2014-11-11 학술지명변경 한글명 : 대한치과기재학회지 -> 대한치과재료학회지
      외국어명 : J. Korea Res. Soc. Dent. Mater. -> Korean Journal of Dental Materials
      KCI등재
      2013-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2010-01-01 평가 등재 1차 FAIL (등재유지) KCI등재
      2008-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2006-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2003-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2002-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2000-07-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.33 0.33 0.25
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.2 0.18 0.408 0.07
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼