RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재 SCIE SCOPUS

      ORiginal Article : A Novel, Fully Covered Laser-Cut Nitinol Stent with Antimigration Properties for Nonresectable Distal Malignant Biliary Obstruction: A Multicenter Feasibility Study = ORiginal Article : A Novel, Fully Covered Laser-Cut Nitinol Stent with Antimigration Properties for Nonresectable Distal Malignant Biliary Obstruction: A Multicenter Feasibility Study

      한글로보기

      https://www.riss.kr/link?id=A99839250

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Background/Aims: Stent migration occurs frequently, but the prevention of complications resulting from covered self-expandable metal stents (C-SEMSs) remains unresolved. We prospectively assessed a newly developed C-SEMS, a modi-fied covered Zeo stent...

      Background/Aims: Stent migration occurs frequently, but the prevention of complications resulting from covered self-expandable metal stents (C-SEMSs) remains unresolved. We prospectively assessed a newly developed C-SEMS, a modi-fied covered Zeo stent (m-CZS), in terms of its antimigration effect. Methods: Between February 2010 and January 2011, an m-CZS was inserted into 42 patients (31 initial drainage cases and 11 reintervention cases) at a tertiary referral center and three affiliated hospitals. The laser-cut stent was flared for 1.5 cm at both ends, with a 1 cm raised bank located 1 cm in from each flared end. The main outcome of this study was the rate of stent migration, and second-ary outcomes were the rate of recurrent biliary obstruction (RBO), the time to RBO, the frequencies of complications, and overall survival. Results: Of the 31 patients with initial drainage, stent migration occurred in four (12.9%, 95% con-fidence interval, 5.1% to 29.0%), with a mean time of 131 days. RBO occurred in 18 (58%), with a median time to RBO of 107 days. Following previous C-SEMS migration, seven of 10 patients (70%) did not experience m-CZS migration until death. Conclusions: m-CZSs with antimigration properties ef-fectively, although not completely, prevented stent migration after stent insertion. (Gut Liver 2013;7:725-730)

      더보기

      참고문헌 (Reference)

      1 Isayama H, "Self-expandable metallic stent with high axial force is the risk factor of cholecystitis" 75 (75): AB380-, 2012

      2 Kawakubo K, "Risk factors for pancreatitis following transpapillary self-expandable metal stent placement" 26 : 771-776, 2012

      3 Tada M, "Recent progress and limitations of chemotherapy for pancreatic and biliary tract cancers" 2 : 158-163, 2011

      4 Shimizu S, "Predictive factors for pancreatitis and cholecystitis in endoscopic covered metal stenting for distal malignant biliary obstruction" 28 : 68-72, 2013

      5 Isayama H, "Polyurethane-covered metal stent for management of distal malignant biliary obstruction" 55 : 366-370, 2002

      6 Nakai Y, "New method of covered wallstents for distal malignant biliary obstruction to reduce early stent-related complications based on characteristics" 23 : 49-55, 2011

      7 Moon SH, "Modified fully covered self-expandable metal stents with antimigration features for benign pancreatic-duct strictures in advanced chronic pancreatitis, with a focus on the safety profile and reducing migration" 72 : 86-91, 2010

      8 Saleem A, "Meta-analysis of randomized trials comparing the patency of covered and uncovered self-expandable metal stents for palliation of distal malignant bile duct obstruction" 74 : 321-327, 2011

      9 Isayama H, "Measurement of radial and axial forces of biliary self-expandable metallic stents" 70 : 37-44, 2009

      10 Isayama H, "Management of distal malignant biliary obstruction with the ComVi stent, a new covered metallic stent" 24 : 131-137, 2010

      1 Isayama H, "Self-expandable metallic stent with high axial force is the risk factor of cholecystitis" 75 (75): AB380-, 2012

      2 Kawakubo K, "Risk factors for pancreatitis following transpapillary self-expandable metal stent placement" 26 : 771-776, 2012

      3 Tada M, "Recent progress and limitations of chemotherapy for pancreatic and biliary tract cancers" 2 : 158-163, 2011

      4 Shimizu S, "Predictive factors for pancreatitis and cholecystitis in endoscopic covered metal stenting for distal malignant biliary obstruction" 28 : 68-72, 2013

      5 Isayama H, "Polyurethane-covered metal stent for management of distal malignant biliary obstruction" 55 : 366-370, 2002

      6 Nakai Y, "New method of covered wallstents for distal malignant biliary obstruction to reduce early stent-related complications based on characteristics" 23 : 49-55, 2011

      7 Moon SH, "Modified fully covered self-expandable metal stents with antimigration features for benign pancreatic-duct strictures in advanced chronic pancreatitis, with a focus on the safety profile and reducing migration" 72 : 86-91, 2010

      8 Saleem A, "Meta-analysis of randomized trials comparing the patency of covered and uncovered self-expandable metal stents for palliation of distal malignant bile duct obstruction" 74 : 321-327, 2011

      9 Isayama H, "Measurement of radial and axial forces of biliary self-expandable metallic stents" 70 : 37-44, 2009

      10 Isayama H, "Management of distal malignant biliary obstruction with the ComVi stent, a new covered metallic stent" 24 : 131-137, 2010

      11 Nakai Y, "Efficacy and safety of the covered Wallstent in patients with distal malignant biliary obstruction" 62 : 742-748, 2005

      12 Nakai Y, "Efficacy and safety of metallic stents in patients with unresectable pancreatic cancer receiving gemcitabine" 37 : 405-410, 2008

      13 Kullman E, "Covered versus uncovered self-expandable nitinol stents in the palliative treatment of malignant distal biliary obstruction: results from a randomized, multicenter study" 72 : 915-923, 2010

      14 Isayama H, "Covered biliary metal stent: which are worse: the concepts, current models, or insertion methods" 73 : 1329-1330, 2011

      15 Mukai T, "Comparison of axial force and cell width of self-expandable metallic stents: which type of stent is better suited for hilar biliary strictures" 18 : 646-652, 2011

      16 Park do H, "Anchoring flap versus flared end, fully covered self-expandable metal stents to prevent migration in patients with benign biliary strictures: a multicenter, prospective, comparative pilot study (with videos)" 73 : 64-70, 2011

      17 Telford JJ, "A randomized trial comparing uncovered and partially covered self-expandable metal stents in the palliation of distal malignant biliary obstruction" 72 : 907-914, 2010

      18 Isayama H, "A prospective randomised study of “covered” versus “uncovered” diamond stents for the management of distal malignant biliary obstruction" 53 : 729-734, 2004

      19 Kasher JA, "A multicenter analysis of safety and outcome of removal of a fully covered self-expandable metal stent during ERCP" 73 : 1292-1297, 2011

      더보기

      동일학술지(권/호) 다른 논문

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-02-25 학회명변경 한글명 : 거트앤리버 발행위원회 -> 거트앤리버 소화기연관학회협의회 KCI등재
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2013-10-01 평가 등재학술지 선정 (기타) KCI등재
      2012-01-01 평가 등재후보학술지 유지 (기타) KCI등재후보
      2011-01-01 평가 등재후보 1차 FAIL (등재후보1차) KCI등재후보
      2009-01-01 평가 SCIE 등재 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 2.29 0.44 1.5
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      1.21 1.02 0.46 0.28
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼