      다국어 초록 (Multilingual Abstract)

      The Selectatec mounting system was devised to provide easy and quick on-site fitting of various vaporizers for the anesthetic machine. However, a quick changing system for the vaporizer can also damage the O-ring due to friction between the vaporizer ...

      The Selectatec mounting system was devised to provide easy and quick on-site fitting of various vaporizers for the anesthetic machine.
      However, a quick changing system for the vaporizer can also damage the O-ring due to friction between the vaporizer and the Selectatec back bar. We herein report a case of an unexpected anesthetic gas leakage from a damaged O-ring on the Selectatec back bar, which resulted from exchanging the vaporizers between two operations. In cases using the Datex Ohmeda machine, it is not easy to detect leakages from the vaporizers because of the location of the check valve near to the fresh gas outlet. This complicates the use of the positive pressure leakage test to detect a low pressure system leakage on the Selectatec back bar. We recommend the preanesthetic negative pressure or low-flow leakage test to detect a low pressure leakage when exchanging vaporizers on the Selectatec system.

      더보기

      참고문헌 (Reference)

      1 Subrahmanyam M, "Safety features in anaesthesia machine" 57 : 472-480, 2013

      2 Avidan MS, "Prevention of awareness during general anesthesia" 1 : 2009

      3 Berry PD, "Missing O-ring causes unrecognised large gas leak" 47 : 359-, 1992

      4 Smith FD, "Management of exposure to waste anesthetic gases" 91 : 482-494, 2010

      5 Tanaka M, "Leakage of sevoflurane from vaporizer detected by air monitoring system : a case report" 27 : 629-631, 2013

      6 김효진, "Interruption in the supply of breathing gas during general anesthesia due to malposition of the vaporizer -A case report-" 대한마취통증의학회 59 (59): 270-274, 2010

      7 문성하, "Internal leakage of oxygen flush valve" 대한마취통증의학회 64 (64): 550-551, 2013

      8 Lum ME, "Fault in a Selectatec manifold resulting in awareness" 20 : 501-503, 1992

      9 Morrison JL, "FDA anesthesia apparatus checkout recommendations, 1993" 58 : 25-28, 1994

      10 Cassidy CJ, "Critical incident reports concerning anaesthetic equipment : analysis of the UK National Reporting and Learning System(NRLS)data from 2006-2008*" 66 : 879-888, 2011

      1 Subrahmanyam M, "Safety features in anaesthesia machine" 57 : 472-480, 2013

      2 Avidan MS, "Prevention of awareness during general anesthesia" 1 : 2009

      3 Berry PD, "Missing O-ring causes unrecognised large gas leak" 47 : 359-, 1992

      4 Smith FD, "Management of exposure to waste anesthetic gases" 91 : 482-494, 2010

      5 Tanaka M, "Leakage of sevoflurane from vaporizer detected by air monitoring system : a case report" 27 : 629-631, 2013

      6 김효진, "Interruption in the supply of breathing gas during general anesthesia due to malposition of the vaporizer -A case report-" 대한마취통증의학회 59 (59): 270-274, 2010

      7 문성하, "Internal leakage of oxygen flush valve" 대한마취통증의학회 64 (64): 550-551, 2013

      8 Lum ME, "Fault in a Selectatec manifold resulting in awareness" 20 : 501-503, 1992

      9 Morrison JL, "FDA anesthesia apparatus checkout recommendations, 1993" 58 : 25-28, 1994

      10 Cassidy CJ, "Critical incident reports concerning anaesthetic equipment : analysis of the UK National Reporting and Learning System(NRLS)data from 2006-2008*" 66 : 879-888, 2011

      11 Myers JA, "Comparison of tests for detecting leaks in the low-pressure system of anesthesia gas machines" 84 : 179-184, 1997

      12 Pandit JJ, "Broken O-ring causing hypoventilation" 48 : 1114-1115, 1993

      13 Ehrenwerth J, "Anesthesia Equipment:Principles and Applications" Elsevier Health Sciences 768-, 2013

      14 Goneppanavar U, "Anaesthesia machine: checklist, hazards, scavenging" 57 : 533-540, 2013

      15 Tokumine J, "A comparison between low-flow leak test and oxygen flush leak test" 14 : 191-193, 2000

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2027 평가예정 재인증평가 신청대상 (재인증)
      2021-01-01 평가 등재학술지 유지 (재인증) KCI등재
      2018-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2015-01-01 평가 등재학술지 선정 (계속평가) KCI등재
      2013-11-27 학회명변경 한글명 : 대한마취과학회 -> 대한마취통증의학회 KCI등재후보
      2013-01-01 평가 등재후보학술지 유지 (기타) KCI등재후보
      2012-01-01 평가 등재후보학술지 유지 (기타) KCI등재후보
      2011-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2009-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.13 0.13 0.12
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.13 0.13 0.279 0.04
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼