      사용적합성 평가를 적용한 국산 범용인공호흡기의 위험요인 분석 = Analysis of Hazard Factors for Domestic General Purpose Ventilator using Usability Assessment

      한글로보기

      https://www.riss.kr/link?id=A109135258

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      The purpose of this study is to conduct a summative evaluation of the usability of a general-purpose ventilator to determine whether it can be used for its intended purpose in the intended environment by the intended user and to find possible errors i...

      The purpose of this study is to conduct a summative evaluation of the usability of a general-purpose ventilator to determine whether it can be used for its intended purpose in the intended environment by the intended user and to find possible errors in use. The importance of ventilators has increased due to the accelerated aging of the population and the impact of the pandemic. In addition, patients who require ventilators are often in critical condition, so even a small error in use can be fatal. Therefore, it is important to ensure that the ventilator has sufficient stability and can be used satisfactorily without inconvenience to the user. In this study, we conducted a usability test with 17 respiratory nurses with more than 3 years of experience using the ventilator. We analyzed the task success rate, satisfaction, and opinions of the intended users while going through a total of 17 scenarios. Satisfaction was captured through an ASQ questionnaire and subjective opinions were captured through a detailed opinion questionnaire. The results showed a high level of satisfaction with an average score of 6.3 for the use scenarios. Evaluators expressed satisfaction with the overall visibility and versatility of the features, but noted that improvements were needed for calibration tasks with low task success rates. As the calibration method is different from other equipment, it was suggested that specific explanations of the calibration method and the picture that appears when calibrating are needed, and that if relevant training is provided, the equipment can be used without problems. If the usability evaluation is not limited to securing efficiency and satisfaction from the intended users, but also continuously receives feedback from users to prepare for use in emergency environments such as pandemic situations, it will be very helpful to seize opportunities such as emergency authorization in future situations, and ultimately contribute to patient safety by reducing use errors.

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼