RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재 SCOPUS

      표면근전도 신호의 정상성 검사를 위한 Run-검증과 RA-검증의 정확도 분석

      한글로보기

      https://www.riss.kr/link?id=A99885796

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Most of the statistical signal analysis processed in the time domain and the frequency domain are based on the assumption that the signal is weakly stationary(wide sense stationary). Therefore, it is necessary to know whether the surface EMG signals p...

      Most of the statistical signal analysis processed in the time domain and the frequency domain are based on the assumption that the signal is weakly stationary(wide sense stationary). Therefore, it is necessary to know whether the surface EMG signals processed in the statistical basis satisfy the condition of weak stationarity. The purpose of this study is to analyze the accuracy of the Run-test, modified Run-test, RA(reverse arrangement)-test, and modified RA-test for assessing surface EMG signal stationarity. Six stationary and three non-stationary signals were simulated by using sine wave, AR(autoregressive) modeling, and real surface EMG. The simulated signals were tested for stationarity using nine different methods of Run-test and RA-test. The results showed that the modified Run-test method2 (mRT2) classified exactly the surface EMG signals by stationarity with 100% accuracy. This finding indicates that the mRT2 may be the best way for assessing stationarity in surface EMG signals.

      더보기

      목차 (Table of Contents)

      • Abstract
      • 1. 서론
      • 2. 정상성 검증
      • 3. 실험방법
      • 4. 결과 및 검토
      • Abstract
      • 1. 서론
      • 2. 정상성 검증
      • 3. 실험방법
      • 4. 결과 및 검토
      • 5. 결론
      • References
      더보기

      참고문헌 (Reference)

      1 S. Blanco, "Stationarity of the EEG series" 14 : 395-399, 1995

      2 N. Alves, "Stationarity distributions of mechano myogram signals from isometric contractions of extrinsic hand muscles during functional grasping" 18 (18): 509-515, 2008

      3 H. Sugimoto, "Stationarity and normality test for biomedical data" 7 : 293-304, 1977

      4 M.J. Levonen, "Stationarity analysis of ambient noise in the Baltic sea" 218-221,

      5 J. Lee, "Real time implementation of time varying nonstationary signal identifier and its application to muscle fatigue monitoring" 16 (16): 317-324, 1995

      6 J.S. Bendat, "Random data: analysis and measurement procedures, 2nd ed." John Wiley & Sons 1986

      7 G.F. Inbar, "On surface EMG spectral characterization and its application to diagnostic classification" 31 : 597-604, 1984

      8 M. Bilodeau, "Normality and stationarity of EMG signals of elbow flexor muscles during ramp and step isometric contractions" 7 (7): 87-96, 1997

      9 T. Chau, "Investigating the stationarity of pediatric aspiration signals" 13 (13): 99-105, 2005

      10 J. Banks, "Discrete-event system simulation" Prentice hall 1984

      1 S. Blanco, "Stationarity of the EEG series" 14 : 395-399, 1995

      2 N. Alves, "Stationarity distributions of mechano myogram signals from isometric contractions of extrinsic hand muscles during functional grasping" 18 (18): 509-515, 2008

      3 H. Sugimoto, "Stationarity and normality test for biomedical data" 7 : 293-304, 1977

      4 M.J. Levonen, "Stationarity analysis of ambient noise in the Baltic sea" 218-221,

      5 J. Lee, "Real time implementation of time varying nonstationary signal identifier and its application to muscle fatigue monitoring" 16 (16): 317-324, 1995

      6 J.S. Bendat, "Random data: analysis and measurement procedures, 2nd ed." John Wiley & Sons 1986

      7 G.F. Inbar, "On surface EMG spectral characterization and its application to diagnostic classification" 31 : 597-604, 1984

      8 M. Bilodeau, "Normality and stationarity of EMG signals of elbow flexor muscles during ramp and step isometric contractions" 7 (7): 87-96, 1997

      9 T. Chau, "Investigating the stationarity of pediatric aspiration signals" 13 (13): 99-105, 2005

      10 J. Banks, "Discrete-event system simulation" Prentice hall 1984

      11 O. Paiss, "Autoregressive modeling of surface EMG and its spectrum with application to fatigue" 34 (34): 761-770, 1987

      12 T.W. Beck, "An examination of the Runs test, reverse arrangement test for assessing surface EMG signal stationarity" 156 : 242-248, 2006

      13 D.M. Halliday, "A periodogram-based test for weak stationarity and consistency between sections in time series" 180 : 136-146, 2009

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2010-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2007-01-01 평가 학술지 통합 (기타) KCI등재
      2001-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.27 0.27 0.24
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.21 0.19 0.366 0.08
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼