RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재후보

      Orbscan II system을 이용한 한국인 정시안 각막의 최적구면 분석 = Analysis of Corneal Best-Fit-Sphere Using Orbscan II system in Korean Emmetropia

      한글로보기

      https://www.riss.kr/link?id=A104122892

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      This study was to analysis the values for anterior and posterior Best-Fit Sphere(BFS) in a Korean emmetropic population using the Orbscan II system. Cycloplegic refraction and anterior and posterior BFS were performed 40 eyes of 20 patients and we com...

      This study was to analysis the values for anterior and posterior Best-Fit Sphere(BFS) in a Korean emmetropic population using the Orbscan II system. Cycloplegic refraction and anterior and posterior BFS were performed 40 eyes of 20 patients and we compared the results by sex and between the two eyes. Respectively, the 1, 3, 5mm zone average of anterior BFS showed each 5.63±3.49μm, 4.48±2.81μm and 2.14±1.82μm. The 1, 3, 5mm zone average of posterior BFS showed each 22.54±10.25μm, 15.88±7.55μm and 4.43±4.94μm in 40 emmetropic eyes. Anterior and posterior BFS were not statistically significant difference in male and female using Mann-Witney U test.

      더보기

      국문 초록 (Abstract)

      본 연구는 Orbscan II system을 이용하여 한국인 정시안을 대상으로 전면과 후면의 최적구면 (Best-Fit-Sphere)을 분석하고자 하였다. 20명 40안을 대상으로 조절마비하 굴절검사를 시행하였고 각막 전...

      본 연구는 Orbscan II system을 이용하여 한국인 정시안을 대상으로 전면과 후면의 최적구면 (Best-Fit-Sphere)을 분석하고자 하였다. 20명 40안을 대상으로 조절마비하 굴절검사를 시행하였고 각막 전면과 후면의 최적구면을 남, 녀 두 그룹으로 나누어 비교하였고 우안과 좌안으로 나누어 비교하였다. 20명(40안) 전체 평균 anterior BFS는 1mm 영역에서 5.63±3.49μm, 3mm 영역에서 4.48±2.81μm, 5mm 영역에서는 2.14±1.82μm이었고, posterior BFS 값은 1mm 영역에서 22.54±10.25μm, 3mm 영역에서 15.88±7.55μm, 5mm 영역에서는 4.43±4.94μm이었다. 남자와 여자와의 차이는 Mann-Witney U test로 조사한 결과 anterior, posterior 모두 통계학적으로 유의한 차이가 없었다.

      더보기

      참고문헌 (Reference)

      1 Rao SN, "Role of Orbscan II in screening keratoconus suspects before refractive corneal surgery" 109 : 1642-1646, 2002

      2 "Measuring anterior chamber depth with Orbscan Topography System" 23 : 1351-1355, 1997

      3 Auffarth GU, "Keratoconus evaluation using the Orbscan Topography System" 26 : 222-228, 2000

      4 Belin MW, "Evaluating data acquisition and smoothing functions of currently available videokeratoscopes" 22 : 421-426, 1996

      5 Hyuk Jin Choi, "Diagnostic Criteria for Keratoconus Using Orbscan Ⅱ Slit Scanning Topography/Pachymetry System" 45 : 928-935, 2004

      6 American Academy of Ophthalmology, "Corneal topography" 106 : 1628-1638, 1999

      7 Pflugfelder SC, "Corneal thickness indices discriminate between keratoconus and contact lensinduced corneal thinning" 109 : 2336-2341, 2002

      8 Greivenkamp JE, "Comparison of three videokeratoscopes in measurement of toric test surface" 12 : 229-239, 1996

      9 Robert C, "Characterization of the inherent error in a spherically -biased corneal topography system in mapping a radially aspheric surface" 103-111, 1994

      10 "Central and peripheral corneal thickness measurement with Orbscan II and topographical ultrasound pachymetry" 29 : 125-132, 2003

      1 Rao SN, "Role of Orbscan II in screening keratoconus suspects before refractive corneal surgery" 109 : 1642-1646, 2002

      2 "Measuring anterior chamber depth with Orbscan Topography System" 23 : 1351-1355, 1997

      3 Auffarth GU, "Keratoconus evaluation using the Orbscan Topography System" 26 : 222-228, 2000

      4 Belin MW, "Evaluating data acquisition and smoothing functions of currently available videokeratoscopes" 22 : 421-426, 1996

      5 Hyuk Jin Choi, "Diagnostic Criteria for Keratoconus Using Orbscan Ⅱ Slit Scanning Topography/Pachymetry System" 45 : 928-935, 2004

      6 American Academy of Ophthalmology, "Corneal topography" 106 : 1628-1638, 1999

      7 Pflugfelder SC, "Corneal thickness indices discriminate between keratoconus and contact lensinduced corneal thinning" 109 : 2336-2341, 2002

      8 Greivenkamp JE, "Comparison of three videokeratoscopes in measurement of toric test surface" 12 : 229-239, 1996

      9 Robert C, "Characterization of the inherent error in a spherically -biased corneal topography system in mapping a radially aspheric surface" 103-111, 1994

      10 "Central and peripheral corneal thickness measurement with Orbscan II and topographical ultrasound pachymetry" 29 : 125-132, 2003

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2022 평가예정 재인증평가 신청대상 (재인증)
      2019-01-01 평가 등재학술지 유지 (계속평가) KCI등재
      2016-01-01 평가 등재학술지 유지 (계속평가) KCI등재
      2012-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2009-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2008-01-17 학회명변경 영문명 : The Korean Ophalmic Optics Society -> The Korean Ophthalmic Optics Society KCI등재후보
      2008-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2006-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.62 0.62 0.53
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.58 0.58 0.691 0.17
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼