      Phase Contrast Microradiography of Mouse Lung Using Synchrotron X-ray: Correlation with Optical Microscopy

      한글로보기

      https://www.riss.kr/link?id=A101618014

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Purpose: The purpose of this study is to evaluate the feasibility of phase contrast X-ray microtomography and microradiography, using a polychromatic synchrotron X-ray, for analysis of the mouse lung microstructure. Materials and Methods: Normal mice ...

      Purpose: The purpose of this study is to evaluate the feasibility of phase contrast X-ray microtomography and
      microradiography, using a polychromatic synchrotron X-ray, for analysis of the mouse lung microstructure.
      Materials and Methods: Normal mice were used for experiments. Some of the mouse lungs were prepared by the
      lung fixation-inflation method. The resulting sponge-like inflated lung samples were used for microtomography.
      The remaining mouse lungs were cut into 10 um sections and were used for microradiography and optical
      microscopic correlation. The experiments on mouse lung samples were performed at the 7B2 beamline of the
      Pohang Light Source in Korea. Results: Phase contrast X-ray microtomography of inflated lung samples showed
      individual alveolar structure on 3-D reconstruction. Phase contrast microradiographs of thin lung samples showed
      microstructure of lung, such as alveoli and bronchioles, and were well correlated with optical microscopic images.
      Conclusions: The results indicate that the phase contrast X-ray microtomography and microradiography using
      polychromatic synchrotron X-ray is feasible for evaluation of microstructure of the lung.

      더보기

      다국어 초록 (Multilingual Abstract)

      Purpose: The purpose of this study is to evaluate the feasibility of phase contrast X-ray microtomography and microradiography, using a polychromatic synchrotron X-ray, for analysis of the mouse lung microstructure. Materials and Methods: Normal mic...

      Purpose: The purpose of this study is to evaluate the feasibility of phase contrast X-ray microtomography and
      microradiography, using a polychromatic synchrotron X-ray, for analysis of the mouse lung microstructure.
      Materials and Methods: Normal mice were used for experiments. Some of the mouse lungs were prepared by the
      lung fixation-inflation method. The resulting sponge-like inflated lung samples were used for microtomography.
      The remaining mouse lungs were cut into 10 um sections and were used for microradiography and optical
      microscopic correlation. The experiments on mouse lung samples were performed at the 7B2 beamline of the
      Pohang Light Source in Korea. Results: Phase contrast X-ray microtomography of inflated lung samples showed
      individual alveolar structure on 3-D reconstruction. Phase contrast microradiographs of thin lung samples showed
      microstructure of lung, such as alveoli and bronchioles, and were well correlated with optical microscopic images.
      Conclusions: The results indicate that the phase contrast X-ray microtomography and microradiography using
      polychromatic synchrotron X-ray is feasible for evaluation of microstructure of the lung.

      더보기

      참고문헌 (Reference)

      1 Meuli R, "Synchrotron radiation in radiology: radiology techniques based on synchrotron sources" 14 : 1550-1560, 2004

      2 Tong Y, "Synchrotron microradiography study on acute lung injury of mouse caused by PM(2.5) aerosols" 58 : 266-272, 2006

      3 Hwu Y, "Synchrotron microangiography with no contrast agent" 49 : 501-508, 2004

      4 Sera T, "Refraction-enhanced tomography of mouse and rabbit lungs" 32 : 2787-2792, 2005

      5 Gao D, "Phase-contrast radiography" 18 : 1257-1267, 1998

      6 Kitchen MJ, "Phase contrast X-ray imaging of mice and rabbit lungs: a comparative study" 78 : 1018-1027, 2005

      7 Kitchen MJ, "On the origin of speckle in x-ray phase contrast images of lung tissue" 49 : 4335-4348, 2004

      8 Watz H, "Micro-CT of the human lung: imaging of alveoli and virtual endoscopy of an alveolar duct in a normal lung and in a lung with centrilobular emphysema-- initial observations" 236 : 1053-1058, 2005

      9 Lewis RA, "Medical phase contrast x-ray imaging: current status and future prospects" 49 : 3573-3583, 2004

      10 Jheon S, "High-resolution X-ray refraction imaging of rat lung and histological correlations" 69 : 656-659, 2006

      1 Meuli R, "Synchrotron radiation in radiology: radiology techniques based on synchrotron sources" 14 : 1550-1560, 2004

      2 Tong Y, "Synchrotron microradiography study on acute lung injury of mouse caused by PM(2.5) aerosols" 58 : 266-272, 2006

      3 Hwu Y, "Synchrotron microangiography with no contrast agent" 49 : 501-508, 2004

      4 Sera T, "Refraction-enhanced tomography of mouse and rabbit lungs" 32 : 2787-2792, 2005

      5 Gao D, "Phase-contrast radiography" 18 : 1257-1267, 1998

      6 Kitchen MJ, "Phase contrast X-ray imaging of mice and rabbit lungs: a comparative study" 78 : 1018-1027, 2005

      7 Kitchen MJ, "On the origin of speckle in x-ray phase contrast images of lung tissue" 49 : 4335-4348, 2004

      8 Watz H, "Micro-CT of the human lung: imaging of alveoli and virtual endoscopy of an alveolar duct in a normal lung and in a lung with centrilobular emphysema-- initial observations" 236 : 1053-1058, 2005

      9 Lewis RA, "Medical phase contrast x-ray imaging: current status and future prospects" 49 : 3573-3583, 2004

      10 Jheon S, "High-resolution X-ray refraction imaging of rat lung and histological correlations" 69 : 656-659, 2006

      11 Start A, "Groskint. Heintzman’s The Lung: Radiological-Pathological Correlations" Mosby 1993

      12 Lewis RA, "Dynamic imaging of the lungs using x-ray phase contrast" 50 : 5031-5040, 2005

      13 Langheinrich AC, "Acute rat lung injury: feasibility of assessment with micro-CT" 233 : 165-171, 2004

      더보기

      동일학술지(권/호) 다른 논문

      동일학술지 더보기

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2011-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2009-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2007-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2005-05-31 학술지등록 한글명 : Yonsei Medical Journal
      외국어명 : Yonsei Medical Journal
      KCI등재
      2005-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2002-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2000-01-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 1.42 0.3 0.99
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.83 0.72 0.546 0.08
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼