RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재 SCOPUS

      Assessment of the accuracy of laser-scanned models and 3-dimensional rendered cone-beam computed tomographic images compared to digital caliper measurements on plaster casts

      한글로보기

      https://www.riss.kr/link?id=A107955809

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Purpose: This study investigated the accuracy of laser-scanned models and 3-dimensional (3D) rendered cone-beam computed tomography (CBCT) compared to the gold standard (plaster casts) for linear measurements on dental arches. Materials and Methods: C...

      Purpose: This study investigated the accuracy of laser-scanned models and 3-dimensional (3D) rendered cone-beam computed tomography (CBCT) compared to the gold standard (plaster casts) for linear measurements on dental arches.
      Materials and Methods: CBCT scans and plaster models from 30 patients were retrieved. Plaster models were scanned by an Emerald laser scanner (Planmeca, Helsinki, Finland). Sixteen different measurements, encompassing the mesiodistal width of teeth and both arches’ length and width, were calculated using various landmarks. Linear measurements were made on laser-scanned models using Autodesk Meshmixer software v. 3.0 (Autodesk, Mill Valley, CA, USA), on 3D-rendered CBCT models using OnDemand 3D v. 1.0 (Cybermed, Seoul, Korea) and on plaster casts by a digital caliper. Descriptive statistics, the paired t-test, and intra- and inter-class correlation coefficients were used to analyze the data.
      Results: There were statistically significant differences between some measurements on plaster casts and laser- scanned or 3D-rendered CBCT models (P<0.05). Molar mesiodistal width and mandibular anterior arch width deviated significantly different from the gold standard in both methods. The largest mean differences of laser- scanned and 3D-rendered CBCT models compared to the gold standard were 0.12±0.23 mm and 0.42±0.53 mm, respectively. Most of the mean differences were not clinically significant. The intra- and inter-class correlation results were acceptable for all measurements (>0.830) and between observers (>0.801).
      Conclusion: The 3D-rendered CBCT images and laser-scanned models were useful and accurate alternatives to conventional plaster models. They could be used for clinical purposes in orthodontics and prostheses.

      더보기

      참고문헌 (Reference)

      1 Wiranto MG, "Validity, reliability, and reproducibility of linear measurements on digital models obtained from intraoral and cone-beam computed tomography scans of alginate impressions" 143 : 140-147, 2013

      2 Naidu D, "Validity, reliability and reproducibility of three methods used to measure tooth widths for bolton analyses" 25 : 97-103, 2009

      3 Lagravère MO, "Threedimensional accuracy of measurements made with software on cone-beam computed tomography images" 134 : 112-116, 2008

      4 El-Zanaty HM, "Three-dimensional dental measurements : an alternative to plaster models" 137 : 259-265, 2010

      5 Engelbrecht WP, "The influence of the segmentation process on 3D measurements from cone beam computed tomography-derived surface models" 17 : 1919-1927, 2013

      6 Lightheart KG, "Surface analysis of study models generated from OrthoCAD and cone-beam computed tomography imaging" 141 : 686-693, 2012

      7 Poleti ML, "Rubira-Bullen IR. Reliability and accuracy of automatic segmentation of mandibular 3D models on linear measurements"

      8 Watanabe-Kanno GA, "Reproducibility, reliability and validity of measurements obtained from Cecile3 digital models" 23 : 288-295, 2009

      9 Reuschl RP, "Reliability and validity of measurements on digital study models and plaster models" 38 : 22-26, 2016

      10 Baumgaertel S, "Reliability and accuracy of cone-beam computed tomography dental measurements" 136 : 19-25, 2009

      1 Wiranto MG, "Validity, reliability, and reproducibility of linear measurements on digital models obtained from intraoral and cone-beam computed tomography scans of alginate impressions" 143 : 140-147, 2013

      2 Naidu D, "Validity, reliability and reproducibility of three methods used to measure tooth widths for bolton analyses" 25 : 97-103, 2009

      3 Lagravère MO, "Threedimensional accuracy of measurements made with software on cone-beam computed tomography images" 134 : 112-116, 2008

      4 El-Zanaty HM, "Three-dimensional dental measurements : an alternative to plaster models" 137 : 259-265, 2010

      5 Engelbrecht WP, "The influence of the segmentation process on 3D measurements from cone beam computed tomography-derived surface models" 17 : 1919-1927, 2013

      6 Lightheart KG, "Surface analysis of study models generated from OrthoCAD and cone-beam computed tomography imaging" 141 : 686-693, 2012

      7 Poleti ML, "Rubira-Bullen IR. Reliability and accuracy of automatic segmentation of mandibular 3D models on linear measurements"

      8 Watanabe-Kanno GA, "Reproducibility, reliability and validity of measurements obtained from Cecile3 digital models" 23 : 288-295, 2009

      9 Reuschl RP, "Reliability and validity of measurements on digital study models and plaster models" 38 : 22-26, 2016

      10 Baumgaertel S, "Reliability and accuracy of cone-beam computed tomography dental measurements" 136 : 19-25, 2009

      11 Fleming PS, "Orthodontic measurements on digital study models compared with plaster models : a systematic review" 14 : 1-16, 2011

      12 Luu NS, "Linear measurements using virtual study models" 82 : 1098-1106, 2012

      13 De Luca Canto G, "Intra-arch dimensional measurement validity of laser-scanned digital dental models compared with the original plaster models : a systematic review" 18 : 65-76, 2015

      14 Ballrick JW, "Image distortion and spatial resolution of a commercially available cone-beam computed tomography machine" 134 : 573-582, 2008

      15 Kau CH, "Evaluation of CBCT digital models and traditional models using the Little’s Index" 80 : 435-439, 2010

      16 Rossini G, "Diagnostic accuracy and measurement sensitivity of digital models for orthodontic purposes : a systematic review" 149 : 161-170, 2016

      17 Sfondrini MF, "Computerized casts for orthodontic purpose using powder-free intraoral scanners : accuracy, execution time, and patient feedback" 2018 : 4103232-, 2018

      18 Hirogaki Y, "Complete 3-D reconstruction of dental cast shape using perceptual grouping" 20 : 1093-1101, 2001

      19 Massaro C, "Comparison of linear and angular changes assessed in digital dental models and cone-beam computed tomography" 23 : 118-128, 2020

      20 Ko HC, "Agreement of treatment recommendations based on digital vs plaster dental models" 155 : 135-142, 2019

      21 Kim J, "Accuracy of laser-scanned models compared to plaster models and cone-beam computed tomography" 84 : 443-450, 2014

      22 Ye N, "Accuracy of in-vitro tooth volumetric measurements from cone-beam computed tomography" 142 : 879-887, 2012

      23 Olszewski R, "Accuracy of digital dental models using the low-cost DAVID laser scanner" 28 : 1647-1656, 2019

      24 Jooseong Kim, "Accuracy of Bolton analysis measured in laser scanned digital models compared with plaster models (gold standard) and cone-beam computer tomography images" 대한치과교정학회 46 (46): 13-19, 2016

      25 Camardella LT, "Accuracy and reproducibility of measurements on plaster models and digital models created using an intraoral scanner" 78 : 211-220, 2017

      26 Leonardo T. Camardella, "Accuracy and reliability of measurements performed using two different software programs on digital models generated using laser and computed tomography plaster model scanners" 대한치과교정학회 50 (50): 13-25, 2020

      27 Creed B, "A comparison of the accuracy of linear measurements obtained from cone beam computerized tomography images and digital models" 17 : 49-56, 2011

      28 Keating AP, "A comparison of plaster, digital and reconstructed study model accuracy" 35 : 191-201, 2008

      29 Tarazona B, "A comparison between dental measurements taken from CBCT models and those taken from a digital method" 35 : 1-6, 2013

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      인용정보 인용지수 설명보기

      학술지 이력

      학술지 이력
      연월일 이력구분 이력상세 등재구분
      2023 평가예정 해외DB학술지평가 신청대상 (해외등재 학술지 평가)
      2020-01-01 평가 등재학술지 유지 (해외등재 학술지 평가) KCI등재
      2019-03-27 학회명변경 한글명 : 대한구강악안면방사선학회 -> 대한영상치의학회 KCI등재
      2012-04-16 학술지명변경 한글명 : 대한구강악안면방사선학회지 -> Imaging Science in Dentistry KCI등재
      2011-03-29 학술지명변경 외국어명 : Korean Journal of Oral and Maxillofacial Radiology -> Imaging Science in Dentistry KCI등재
      2010-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2008-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2006-01-01 평가 등재학술지 유지 (등재유지) KCI등재
      2003-01-01 평가 등재학술지 선정 (등재후보2차) KCI등재
      2002-01-01 평가 등재후보 1차 PASS (등재후보1차) KCI등재후보
      2000-07-01 평가 등재후보학술지 선정 (신규평가) KCI등재후보
      더보기

      학술지 인용정보

      학술지 인용정보
      기준연도 WOS-KCI 통합IF(2년) KCIF(2년) KCIF(3년)
      2016 0.12 0.12 0.11
      KCIF(4년) KCIF(5년) 중심성지수(3년) 즉시성지수
      0.11 0.12 0.217 0.02
      더보기

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼