RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      KCI등재

      $PerioTest^{(R)}$를 이용한 임플란트 동요도에 관한 임상적 연구 = [ $PERIOTEST^{(R)}$ ] ASSESSMENT OF DENTAL IMPLANT MOBILITY : A CLINCAL STUDY

      한글로보기

      https://www.riss.kr/link?id=A100748707

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      Assessment of implant mobility is an important and reliable method to clinically evaluate implant stability. PerioTest is a precise and reproducible device that cam dynamically measure the reaction of damping characteristics of peri-implant tissue. Th...

      Assessment of implant mobility is an important and reliable method to clinically evaluate implant stability. PerioTest is a precise and reproducible device that cam dynamically measure the reaction of damping characteristics of peri-implant tissue. The aim of this study is to evaluate the effects of amount of implant surface area, diameter, type, implantation site, degrees of cortical engagement, and length of time in function on PTVs and to find out the most determining factor on PTVs. The results are as follows 1. 5.0mm diameter implants show significantly lower PTV than that of 3.75mm diameter implants. 2. PTV in the mandible is significantly lower than that of the maxilla 3. In the maxilla, there is no significant difference in PTV during the first year of implant function, but during the second year a significant decrease in PTV is noted. 4. In the mandible, there is a significant decrease in PTV during the first and second year of implant function. 5. Implantation site seems to be the most determining factor on PTV among the influencing factors in this study. In conclusion, the amount of implant surface area, type, degrees of cortical engagement had no significant effect on PTV, but installation site and diameter influenced significantly on PTV

      더보기

      동일학술지(권/호) 다른 논문

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼