      ATP 측정기를 이용한 종이 표면의 세균 오염 평가 = Evaluation of bacterial contamination on paper surfaces using ATP bioluminometers

      한글로보기

      https://www.riss.kr/link?id=A108775103

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract)

      ATP luminescence measurements (using Relative Light Units, RLU) has been used to assess the levels of bacterial contamination on the surfaces of various materials. However, not much is known about their suitability in assessing bacterial contamination...

      ATP luminescence measurements (using Relative Light Units, RLU) has been used to assess the levels of bacterial contamination on the surfaces of various materials. However, not much is known about their suitability in assessing bacterial contamination on paper surfaces. This study was conducted to evaluate the feasibility of using ATP luminometers in measuring levels of bacteria contamination on paper surfaces. The three ATP luminometers studied were Clean-Q, smart PD-30, and 3M™ Clean-Trace™ LM1 manufactured by different companies. There were some differences in RLU results among the three ATP luminometers when they were tested with different concentrations of Micrococcus luteus cell suspension. 106 - 107 cells were required in order to effectively detect Bacillus subtilis, Escherichia coli, and Micrococcus luteus on the surfaces of A4 printing sheets (100 cm2 ) when using the three ATP luminometers. The sizes and physical properties of surface areas varied slightly among the swabs used for the three ATP luminometers. Concentration-specific measurements (RLU) of M. luteus taken from the surfaces of six kinds of paper (fine print paper, medium print paper, ground paper, newsprint paper, practice paper, tracing paper) were possible using the smart PD-30 and LM1 ATP luminometers. ATP detection values of M. luteus varied among the six types of paper. The highest ATP detection values were found on the surfaces of tracing paper. If the RLU value is recorded at the level of 1000, this could indicate a very high bacterial contamination level of 105 to 106 CFU/4 cm.

      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼